Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomed Chromatogr ; 36(10): e5436, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35766584

RESUMEN

Amitriptyline hydrochloride is an antidepressant drug with sedative effects used to treat the symptoms of anxiety, agitation with depression and schizophrenia with depression. A reversed-phase high-performance liquid chromatography method was developed to separate and quantitatively determine the assay and four organic impurities of amitriptyline in tablet dosage form and bulk drugs using a C18 column in an isocratic elution mode with mobile phase consisting of a mixture of pH 7.5 phosphate buffer and methanol. The pH conditions used in the chromatographic separation are discussed. The stability-indicating characteristics of the proposed method were proved using stress testing [5 m HCl at 80°C/1 h, 5 m NaOH at 80°C/1 h, H2 O (v/w) at 80°C/1 h, 6% H2 O2 (v/v) at 25°C/1 h, dry heat at 105°C/24 h and UV-vis light/4 days] and validated for specificity, detection limit, quantitation limit, linearity, precision, accuracy and robustness. For amitriptyline and its four known organic impurities, the quantitation limits, linearity and recoveries were in the ranges 0.25-3.0 µg/ml (r2 > 0.999) and 87.9-107.6%, respectively. The mass (m/z) spectral data of amitriptyline hydrochloride and its impurity are discussed. The proposed LC method is also suitable for impurity profiling and assay determination of amitriptyline in bulk drugs and pharmaceutical formulations.


Asunto(s)
Amitriptilina , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Estabilidad de Medicamentos , Comprimidos
2.
Biomed Chromatogr ; 36(4): e5330, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34994006

RESUMEN

Montelukast sodium (MLS) is a leukotriene receptor antagonist drug used in the treatment of asthma, bronchospasm, allergic rhinitis and urticaria. A reversed-phase high performance liquid chromatography method was developed to separate, identify and quantitative determination of MLS and its eight known organic impurities in tablet dosage form using a C18 column and mobile phases consisting of a gradient mixture of pH 2.5 phosphate buffer and acetonitrile. The stability-indicating character of the developed method was proven using stress testing (1 m HCl at 80°C/30 min, 1 m NaOH at 80°C/30 min, H2 O at 80°C/30 min, 3% H2 O2 at 25°C/1 min, dry heat at 105°C/10 h and UV-vis light/4 days) and was validated for specificity, quantitation limit, linearity, precision, accuracy and robustness. For MLS and its eight known impurities, the quantitation limits, linearity and recoveries were 0.015-0.03 µg/ml, correlation coefficient > 0.997 (R2 > 0.995) and 85.5-107.0%, respectively. The developed chromatographic method is suitable for impurity profiling and also for assay determination of MLS in bulk drugs and pharmaceutical formulations. The mass values (m/z) of newly formed degradation products (DP1 and DP2) of montelukast sodium were identified using liquid chromatography-mass spectrometry.


Asunto(s)
Cromatografía Líquida de Alta Presión , Acetatos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida , Ciclopropanos , Estabilidad de Medicamentos , Quinolinas , Reproducibilidad de los Resultados , Sulfuros , Comprimidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA