Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Orthop Relat Res ; (356): 93-110, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9917673

RESUMEN

A prospective, observational cohort investigation was performed to help understand the impact of knee replacement on patients with knee osteoarthritis in community practice. Of those, 291 patients (330 knees) were eligible and willing to participate. Forty-eight orthopaedic surgeons referred 563 patients from 25 institutions within the state of Indiana. Demographics, patient completed health status, satisfaction, independent radiographic measures, surgeon reported intraoperative factors, hospital discharge factors, and independent physical examinations were recorded. A minimum 2-year followup was obtained in 92% of the patients. At followup, 88% were satisfied, 3% were neutral, and 9% were dissatisfied with the results of their knee surgery. The physical composite score improved from 27.4 +/- 0.4 (range, 13.3-50.3) to 37.7 +/- 0.7 (range, 12.9-61.3) at two years. Maximal improvement in physical composite score was seen in patients who had their surgery performed in institutions that performed greater than 50 knee replacements per year in patients with Medicare insurance; who had a better mental health status at baseline; who had surgery performed on Monday, Friday, or Saturday; who were older; who were treated with a posterior cruciate sparing device; and who had worse preoperative function. A lower likelihood of complications were found with surgeons who performed greater than 20 knee replacements per year; midweek surgeries; in patients with more severe preoperative knee dysfunction; patients with fewer comorbidities; patients with less preoperative stiffness; patients being treated by younger surgeons; and in patients undergoing unilateral knee replacement. Among voluntarily participating physicians, knee replacement can be a highly effective medical technology with high levels of patient satisfaction and low rates of complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis/cirugía , Factores de Edad , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Competencia Clínica , Femenino , Indicadores de Salud , Humanos , Indiana , Modelos Logísticos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Evaluación de Procesos, Atención de Salud , Estudios Prospectivos , Rango del Movimiento Articular , Resultado del Tratamiento
2.
J Arthroplasty ; 10(5): 575-80, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9273366

RESUMEN

A survey was conducted of the entire membership of the American Association of Hip and Knee Surgeons to determine their experience with total hip arthroplasty (THA) device-related failures. Forty-seven percent of the membership reviewed their preceding 5-year clinical experience and returned the survey instrument. The aggregate 5-year volume encompassed experience with more than 60,000 hip arthroplasties. The median 5-year experience per respondent was 200 metal-based sockets and 214 metal stems. The frequency distribution of the number of hip arthroplasties per respondent was skewed to the right, with fewer surgeons reporting the higher volumes of arthroplasties. In aggregate, 60,115 of the acetabular components used were metal backed. Nonmetal acetabular component usage totaled 3,219. Complete polyethylene failure was defined as fracture or complete wear through of the polyethylene portion of the component. Complete polyethylene failure was seen in 172 metal-backed sockets (29/10,000). Seventy-seven all-polyethylene sockets had complete polyethylene failure (239/10,100). A total of 87 THAs were revised for modular acetabular dissociations for a dissociation rate of 15/10,000. In aggregate, 64,483 metal-stemmed components were used. Femoral stem fractures occurred in 172 for a rate of 27/10,000. A total of 56,965 metallic femoral components were reported as being modular. Dissociation between the femoral head and neck was uncommonly seen (3/10,000). Use of ceramic femoral heads was low (5,023); however, a total of 11 ceramic head fractures were revised in the 5-year period for a failure rate of 22/10,000. The risks of catastrophic prosthetic THA failure are low but vary according to hip component and the manufacturer of the part.


Asunto(s)
Prótesis de Cadera/estadística & datos numéricos , Cerámica , Recolección de Datos , Humanos , Metales , Polietilenos , Diseño de Prótesis , Falla de Prótesis , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA