1.
Acta Neurochir Suppl ; 135: 213-217, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38153472

RESUMEN

The surgical technique and the intraoperative technology that support spinal pedicle screw placement have consistently evolved over the past decades to decrease the misplacement rate of pedicle screws. We retrospectively evaluated our case series by analyzing the period 2016-2020. Patients undergoing pedicle screw fixation for cervical, thoracic, or lumbar spine degenerative diseases have been included. Surgery was carried out with the aid of intraoperative 3D C-arm fluoroscopy to assess and optimize screw placement and/or correct possible mispositioning. Each patient underwent a postoperative CT scan. Our aim was to evaluate the safety and accuracy of pedicle screw placement and estimate the variation in mispositioning rates. We carried out 329 surgical procedures, as follows: 70 cervical, 78 thoracic spine, and 181 lumbar spine surgeries. An excellent overall pedicle screw positioning was obtained, with slight differences between the cervical (98.6%), thoracic (100%), and lumbar (98.9%) tracts. Accordingly, only three patients required a revision surgery owing to mispositioning (0.91%). In particular, intraoperative C-arm fluoroscopy significatively improved the accuracy of thoracic screw positioning, as shown by postoperative CT scans. Our experience proves the crucial role of intraoperative C-arm fluoroscopy in pursuing optimal technical results and improving patient outcomes at follow-up.


Asunto(s)
Tornillos Pediculares , Humanos , Estudios Retrospectivos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Fluoroscopía , Tecnología
2.
Acta Neurochir Suppl ; 135: 283-289, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38153483

RESUMEN

INTRODUCTION: The reduction, stabilization, and maintenance of alignment are the main goals in the surgical treatment of unstable hangman's fractures. The choice of the surgical strategy remains poorly standardized; anterior and/or posterior fusion could be performed; and none of the available clinical studies in the literature have shown significant differences in outcomes or complication rates. Vertebral anatomy, age, comorbidities, patient factors, and surgical experience may guide the treatment choice. METHODS: We present a case of a polytraumatized young woman with an unstable hangman's fracture type II, according to Levine-Edwards classification. We treated the fracture by using a plate with four holes to fix C2-C3 without discectomy and body fusion. RESULTS: We performed a small incision, such as those used for the fixation of odontoid screws, where the working angle allowed us to easily and quickly position the plate by using a minimally invasive approach. CONCLUSION: The stabilization alone, without discectomy and body fusion with the cage, in the same way favored the natural healing of the bone fracture. In our opinion, in some select cases, fixation of C2-C3 alone through a minimally invasive approach allows for bone healing with fewer risks and an easier surgery.


Asunto(s)
Fracturas Óseas , Femenino , Humanos , Columna Vertebral
3.
J Clin Neurosci ; 89: 151-157, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34119260

RESUMEN

Hemostasis represents a fundamental step in every surgical procedure. During neurosurgical procedures, proper and robust hemostasis into confined spaces can significantly reduce the odds of perioperative complications. Over the decades, multiple methods have been applied, and several medical devices have been developed to promote and guarantee proper hemostasis. This study presents a systematic review of the most used intraoperative hemostatic methods and devices in neurosurgery. Insightful research was performed on the PubMed database according to the PRISMA guidelines. This comprehensive review of scientific literature represents a synoptic panel where the most used intraoperative hemostatic methods and devices available today in neurosurgery are classified and described.


Asunto(s)
Hemostasis Quirúrgica/métodos , Hemostasis/efectos de los fármacos , Hemostáticos/uso terapéutico , Procedimientos Neuroquirúrgicos/métodos , Hemostasis/fisiología , Hemostáticos/farmacología , Humanos , Enfermedades del Sistema Nervioso/tratamiento farmacológico , Enfermedades del Sistema Nervioso/cirugía
4.
Neurol India ; 68(5): 1211-1213, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33109879

RESUMEN

The concept of minimally invasive spine surgery (MISS) has gained increasing popularity in the last decades. While MISS holds promise for faster patient recovery, and shorter hospital stays, the removal of the surgical fixation, when required, is still performed by an extensive approach often resulting in disabling pain and discomfort. We describe a novel minimal invasive microscope-assisted technique for lumbar spinal fixation removal. This technique has been successfully applied in a 35-year-old man, affected by back pain despite a previous posterior dynamic MISS L4-S1 fixation. The previous skin incisions were opened and under microscopic vision, the screws and the roads were dissected from the scars and removed. The patient was discharged on postoperative day-1. He reported a progressive improvement of the symptoms with a satisfactory cosmetic result. Minimal invasive microscope-assisted technique for spinal fixation removal offers a simple and effective surgical alternative to the traditional open surgery.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Adulto , Descompresión Quirúrgica , Humanos , Vértebras Lumbares/cirugía , Región Lumbosacra , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS