Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
4.
Clin Pediatr (Phila) ; 62(7): 678-682, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36579855
5.
Open Forum Infect Dis ; 9(3): ofac015, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35146051

RESUMEN

BACKGROUND: Labeled white blood cell scintigraphy (WBCS) has been used for over 40 years to localize an infection source in patients with fever of unknown origin (FUO). It continues to be in widespread use for such patients in modern times, despite the tremendous advances in modern radiological imaging and laboratory medicine. METHODS: We critically evaluated the clinical contribution of WBCS performed in 132 patients with FUO at 7 hospitals from mid-2015 to the end of 2019. For each patient, all radiographic and laboratory results and all electronic clinical notes were carefully evaluated as many days before and after the scan as necessary to arrive at a final diagnosis. RESULTS: Although 50 WBCS (38%) showed positive findings, the majority of these were false positive (FP). Of the 19 true-positive (TP) scans, most were already known or about to become known by tests already ordered at the time of the scan. Only 2 TP scans (1.5%) contributed to the final diagnosis, and these did so only indirectly. FP scans led to 7 unnecessary procedures. CONCLUSIONS: In FUO patients for whom an infection source is not discovered following an appropriate radiographic and laboratory workup, WBCS is not a useful procedure.

8.
J Vasc Interv Radiol ; 32(3): 412-418, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33341340

RESUMEN

PURPOSE: To evaluate whether the recalculation of lung shunt fraction (LSF) is necessary prior to next-stage or same lobe repeat radioembolization. MATERIALS AND METHODS: Retrospective chart review was performed for patients who underwent radioembolization between February 2008 and December 2018. Eighty of 312 patients had repeat mapping angiograms and LSF calculations. A total of 160 LSF calculations were made using planar imaging (155, [97%]) and single-photon emission computed tomography (5 [3%]) technetium-99m macroaggregated albumin hepatic arterial injection imaging. The mean patient age was 61.8 years ± 12.7; 69 (86%) patients had metastatic disease and 11 (14%) had hepatocellular carcinoma. RESULTS: Patients had a median LSF of 5% (interquartile range [IQR] 3%-9%) with a median absolute difference of 1.25 (IQR 0.65-3.4) and a median of 76 days (IQR 42.5-120 days) between repeat LSF calculations. There was a median change in LSF of 0.2% between mapping studies (P = .11). There was no statistical significance between the repeat LSFs regardless of the arterial distribution (P = .79) or between tumor types (P = .75). No patients exceeded lung dose limits using actual or predicted prescribed dose amounts. The actual median lung dose was 2.6 Gy (IQR 1.8-4.4 Gy, maximum = 20.5) for the first radioembolization and 2.0 Gy (IQR 1.3-3.7 Gy, maximum = 10.1) for the second radioembolization. CONCLUSIONS: No significant difference in LSF was identified between different time points and arterial distributions within the same patient undergoing repeat radioembolization. In patients who receive well under 30-Gy lung dose for the initial treatment and a 50-Gy cumulative lung dose, repeat radioembolization treatments in the same patient may not require a repeat LSF calculation.


Asunto(s)
Angiografía , Carcinoma Hepatocelular/terapia , Embolización Terapéutica , Neoplasias Hepáticas/terapia , Pulmón/diagnóstico por imagen , Neumonitis por Radiación/prevención & control , Radiofármacos/administración & dosificación , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Circulación Hepática , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Circulación Pulmonar , Dosis de Radiación , Neumonitis por Radiación/diagnóstico por imagen , Neumonitis por Radiación/etiología , Radiofármacos/efectos adversos , Retratamiento , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación , Resultado del Tratamiento
9.
AJR Am J Roentgenol ; 215(4): 997-1001, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32569513

RESUMEN

OBJECTIVE. We reviewed a retrospective series of 126 18F-fluciclovine PET/CT studies of patients with biochemically recurrent prostate cancer at low (< 1 ng/mL) and very low (< 0.3 ng/mL) prostate-specific antigen (PSA) levels. CONCLUSION. The rate of PET/CT positivity was 33% (15/46) in patients with low PSA levels and 0% (0/17) in patients with very low PSA levels. Our results suggest that 18F-fluciclovine PET/CT can be helpful for localizing recurrence in patients with PSA levels between 0.3 and 1 ng/mL and that 18F-fluciclovine PET/CT is not recommended in patients with PSA levels less than 0.3 ng/mL.


Asunto(s)
Ácidos Carboxílicos , Ciclobutanos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata/diagnóstico por imagen , Radiofármacos , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/sangre , Recurrencia Local de Neoplasia/patología , Antígeno Prostático Específico/sangre , Prostatectomía , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/cirugía , Reproducibilidad de los Resultados , Estudios Retrospectivos
10.
Radiologe ; 60(Suppl 1): 80-89, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32424463

RESUMEN

Accurate imaging is crucial for lesion detection in abdominal organs, for the noninvasive characterization of focal and diffuse abnormalities, and for surgical planning. To accomplish these tasks, several imaging modalities such as multidetector computer tomography (MDCT), magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) are used for abdominal imaging, providing important morphological, functional or metabolic information. More recently, PET/MRI has been gaining attention due to the possibility of combining high-resolution imaging with metabolic imaging. PET/MRI is a novel hybrid imaging technology that in the near future might play a pivotal role in the clinical management of oncologic and inflammatory abdominopelvic diseases. Despite the still limited number of published clinical studies, PET/MRI has been proven to be at least equivalent to PET/CT and to standalone MRI in a variety of oncologic disease. Moreover, in selected and focused clinical studies, it has been proven to outperform current standard of care imaging, for example, in evaluating cholangiocarcinomas, liver metastases, untreated and treated rectal cancer. This has also had an impact on therapeuticmanagement in some studies. Therefore in some institutions, including those of the authors, PET/MRI is becoming the new standard imaging modality in staging treatment-naïve intrahepatic massforming cholangiocarcinomas and prior to complicated hepatic surgery.


Asunto(s)
Abdomen , Imagen Multimodal , Pelvis , Abdomen/diagnóstico por imagen , Humanos , Pelvis/diagnóstico por imagen
11.
Radiologe ; 60(5): 394-404, 2020 May.
Artículo en Alemán | MEDLINE | ID: mdl-32232543

RESUMEN

Accurate imaging is crucial for lesion detection in abdominal organs, for the noninvasive characterization of focal and diffuse abnormalities, and for surgical planning. To accomplish these tasks, several imaging modalities such as multidetector computer tomography (MDCT), magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) are used for abdominal imaging, providing important morphological, functional or metabolic information. More recently, PET/MRI has been gaining attention due to the possibility of combining high-resolution imaging with metabolic imaging. PET/MRI is a novel hybrid imaging technology that in the near future might play a pivotal role in the clinical management of oncologic and inflammatory abdominopelvic diseases. Despite the still limited number of published clinical studies, PET/MRI has been proven to be at least equivalent to PET/CT and to stand-alone MRI in a variety of oncologic disease. Moreover, in selected and focused clinical studies, it has been proven to outperform current standard of care imaging, for example, in evaluating cholangiocarcinomas, liver metastases, untreated and treated rectal cancer. This has also had an impact on therapeutic management in some studies. Therefore in some institutions, including those of the authors, PET/MRI is becoming the new standard imaging modality in staging treatment-naïve intrahepatic mass-forming cholangiocarcinomas and prior to complicated hepatic surgery.


Asunto(s)
Abdomen/diagnóstico por imagen , Imagen Multimodal , Pelvis/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones
13.
BMC Pediatr ; 19(1): 169, 2019 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-31138181

RESUMEN

BACKGROUND: Dog bite injuries are an ongoing concern in pediatrics. The majority of these occur in low- and middle-income countries where resources, especially subspecialty support services, are limited. Scrotal bites are relatively rare, and even fewer cases of abdominal viscus involvement have been described. No case has previously been reported of a dog bite to the scrotum leading to abdominal viscus perforation. CASE PRESENTATION: A 2-year old boy presented with an acute abdomen as the result of a dog bite to his scrotum in the presence of an unrepaired inguinal hernia. Without revisiting a detailed trauma history and exam, this would have been missed, as the dog bite occurred several days prior to presentation and was nearly completely healed. The patient initially had an emergent laparotomy, small bowel resection, and hernia repair. He then suffered from a delayed anastomotic leak requiring repeat laparotomy with creation of an ileostomy. Following a prolonged post-operative course, the patient was discharged home with his ileostomy in place. He returned 3 months later to have his ileostomy reversed and was discharged after an uncomplicated operation in good condition. CONCLUSIONS: This case demonstrates the primacy of an accurate history and physical, specifically with regards to recent trauma, in the presentation of a pediatric patient with an acute abdomen. Acquiring this may involve multiple re-interviews with the family as new facts may come to light. This is especially important in resource limited areas where advanced imaging and laboratory services are not available.


Asunto(s)
Abdomen Agudo/etiología , Mordeduras y Picaduras/complicaciones , Perros , Hernia Inguinal/complicaciones , Escroto/lesiones , Anastomosis Quirúrgica , Fuga Anastomótica , Animales , Preescolar , Hernia Inguinal/cirugía , Humanos , Intestino Delgado/cirugía , Masculino , Radiografía Abdominal
14.
AJR Am J Roentgenol ; 210(4): 866-868, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29446667

RESUMEN

OBJECTIVE: We reviewed the safety of nuclear diuretic renography with furosemide in patients with sulfonamide allergies. The electronic health record was used to uncover any drug effects reported within 30 days of diuretic renograms performed between January 2009 and December 2015. CONCLUSION: Eighty-three of 1103 (7.5%) diuretic renograms were performed on patients with sulfonamide allergies. Two instances of minor rash occurred. No serious reactions occurred. Furosemide is associated with an extremely low risk of minor reactions in patients with sulfonamide allergies.


Asunto(s)
Diuréticos/administración & dosificación , Diuréticos/efectos adversos , Hipersensibilidad a las Drogas , Furosemida/administración & dosificación , Furosemida/efectos adversos , Seguridad del Paciente , Renografía por Radioisótopo , Sulfonamidas/efectos adversos , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
AJR Am J Roentgenol ; 205(4): 873-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26397339

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the utility of radionuclide perfusion lung scanning in the evaluation of primary pulmonary vein stenosis (PVS) in pediatric patients by comparing it with angiography. MATERIALS AND METHODS: We retrospectively identified pediatric patients with primary PVS who underwent both lung scanning and angiography. A cohort of 34 patients was evaluated. The presence of PVS in the right upper, right lower, left upper, and left lower pulmonary veins on angiograms was recorded. Two nuclear medicine physicians evaluated the lung scans for perfusion defects. Agreement between lung scan and angiographic findings was assessed with contingency tables. Sensitivity and specificity of lung scanning for accurate detection of PVS with angiographic findings as the reference standard were assessed by ROC analysis. RESULTS: Angiography depicted PVS in 90 of the total 136 pulmonary veins (66%). Lung scans correctly depicted 65 (72%) of the cases of PVS diagnosed with angiography. The sensitivity and specificity of lung scans were 76.0% and 88.9% for the right upper pulmonary vein, 70.6% and 94.1% for the right lower pulmonary vein, 77.3% and 58.3% for the left upper pulmonary vein, and 65.4% and 87.5% for the left lower pulmonary vein. CONCLUSION: Lung scan findings correlate with angiographic findings in the detection of primary PVS in pediatric patients. Perfusion lung scanning may have a role in angiographically diagnosed PVS by noninvasively showing relative perfusion at the tissue level.


Asunto(s)
Venas Pulmonares/diagnóstico por imagen , Enfermedad Veno-Oclusiva Pulmonar/diagnóstico por imagen , Femenino , Humanos , Lactante , Pulmón/diagnóstico por imagen , Masculino , Radiografía , Cintigrafía , Radiofármacos , Estudios Retrospectivos , Sensibilidad y Especificidad , Agregado de Albúmina Marcado con Tecnecio Tc 99m
17.
Nucl Med Mol Imaging ; 49(3): 217-22, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26279695

RESUMEN

A Schmorl's node is a common incidental finding encountered during radiologic imaging. Despite the vertebral body being a common site of metastatic disease, a lytic lesion adjacent to an endplate with typical imaging features can often confidently be called a Schmorl's node. This is a case report of a patient with a single well-defined FDG-avid papillary thyroid carcinoma metastasis to the spine that had imaging findings characteristic of a Schmorl's node on CT and MRI. This case is important to consider as it demonstrates that the imaging characteristics of metastatic disease and Schmorl's nodes can overlap.

18.
Radiology ; 276(1): 250-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25734555

RESUMEN

The style and tone of the writing in Radiology has changed over the years since its first publication in 1923. Many of the tonal changes have occurred transiently and likely in relation to political and professional issues in play at a particular time. Others represent more consistent trends in the evolution of the professional writing style. In this report, we analyze the tone of the editorial content from 1923 to 2013 in a historical context as well as progressive changes in readability parameters involving both editorial and technical content.


Asunto(s)
Publicaciones Periódicas como Asunto , Edición/estadística & datos numéricos , Radiología , Historia del Siglo XX , Historia del Siglo XXI , América del Norte , Publicaciones Periódicas como Asunto/historia , Edición/historia , Radiología/historia , Lectura , Escritura
19.
Clin Cancer Res ; 21(5): 1028-35, 2015 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25549723

RESUMEN

PURPOSE: To determine whether the selective BRAF inhibitor, dabrafenib, can stimulate radioiodine uptake in BRAF V600E-mutated unresectable or metastatic iodine-refractory papillary thyroid cancer (PTC). EXPERIMENTAL DESIGN: Ten patients with BRAF V600E-mutant iodine-refractory PTC were enrolled. Absence of radioiodine uptake on iodine-131 whole body scan obtained within 14 months of study entry was required. Each patient received dabrafenib (150 mg twice daily) for 25 days before thyrotropin α-stimulated iodine-131 whole body scan (4 mCi/148 MBq). Patients whose scan showed new sites of radioiodine uptake remained on dabrafenib for 17 more days, and then were treated with 150 mCi (5.5 GBq) iodine-131. The primary endpoint of the study was the percentage of patients with new radioiodine uptake after treatment with dabrafenib. RESULTS: Six of 10 patients (60%) demonstrated new radioiodine uptake on whole body scan after treatment with dabrafenib. All 6 were treated with 5.5 GBq iodine-131. Two patients had partial responses and 4 patients had stable disease on standard radiographic restaging at 3 months. Thyroglobulin decreased in 4 of 6 treated patients. One patient developed squamous cell carcinoma of the skin. There were no other significant adverse events attributed to dabrafenib. CONCLUSIONS: Dabrafenib can stimulate radioiodine uptake in patients with metastatic BRAF V600E-mutant iodine-refractory PTC, representing a potential new therapeutic approach for these patients.


Asunto(s)
Carcinoma/genética , Carcinoma/patología , Diferenciación Celular/genética , Mutación , Proteínas Proto-Oncogénicas B-raf/genética , Tolerancia a Radiación/genética , Neoplasias de la Tiroides/genética , Neoplasias de la Tiroides/patología , Anciano , Anciano de 80 o más Años , Carcinoma/diagnóstico , Carcinoma/metabolismo , Carcinoma/terapia , Carcinoma Papilar , Quimioradioterapia Adyuvante , Femenino , Humanos , Imidazoles/administración & dosificación , Imidazoles/efectos adversos , Imidazoles/uso terapéutico , Radioisótopos de Yodo/administración & dosificación , Radioisótopos de Yodo/efectos adversos , Radioisótopos de Yodo/uso terapéutico , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Oximas/administración & dosificación , Oximas/efectos adversos , Oximas/uso terapéutico , Tiroglobulina/metabolismo , Cáncer Papilar Tiroideo , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/terapia , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Imagen de Cuerpo Entero
20.
Laryngoscope ; 125(4): 877-82, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25388656

RESUMEN

OBJECTIVES/HYPOTHESIS: Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. STUDY DESIGN: Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. METHODS: A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. RESULTS: Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. CONCLUSIONS: SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Ganglios Linfáticos/patología , Masculino , Persona de Mediana Edad , Invasividad Neoplásica/patología , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Biopsia del Ganglio Linfático Centinela/métodos , Neoplasias Cutáneas/patología , Neoplasias Cutáneas/cirugía , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA