Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
BMC Med Educ ; 24(1): 979, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39252033

RESUMEN

BACKGROUND: Learning to interpret electrocardiograms (ECGs) is a crucial objective in medical education. Despite its importance, errors in ECGs interpretation are common, and the optimal teaching methods have not yet been clearly established. OBJECTIVES: To evaluate students' confidence in ECGs analysis and their opinion on current teaching methods, and to assess the effectiveness of a new ECG educational approach. METHODS: First, we conducted a survey on ECG learning among fourth to sixth-year medical students. Second, a 5-week multicenter comparative study was conducted with fourth-year medical students during their cardiology internship. Two different teaching methods were used, assigned by center. The first group participated in 5-minutes workshops 4 times a week using a "reversed classroom" method, supervised by a cardiologist, where students took turns selecting, presenting and discussing ECGs. The control group attended a single 2-hour face-to-face ECG course. All participants completed a 30-minute ECGs analysis test at baseline and after 5 weeks. RESULTS: Out of 401 survey respondents, the confidence levels in ECG interpretation were 3/5 (IQR 2-3) for routine situations and 2/5 (IQR 1-3) for emergency situations. Satisfaction with ECG teaching was low (2/5, IQR 1-3) and 96.3% of respondents favored more extensive ECG training. In the comparative study, 52 students from 3 medical schools were enrolled (control group: n = 27; workshop group: n = 25). Both groups showed significant improvement in exam scores from baseline to 5-week (33/100 ± 12/100 to 44/100 ± 12/100, p < 0.0001 for the control group and 36/100 ± 13/100 to 62/100 ± 12/100, p < 0.0001 for the workshop group). The improvement was significantly greater in the workshop group compared to the control group (+ 26 ± 11 vs. + 11 ± 6, p < 0.001). CONCLUSIONS: Among French medical students who initially reported low confidence and insufficient skills in ECG interpretation, the workshop approach using a "reversed classroom" method was found to be more effective than conventional lecture-based teaching during cardiology internship.


Asunto(s)
Competencia Clínica , Electrocardiografía , Estudiantes de Medicina , Humanos , Competencia Clínica/normas , Educación de Pregrado en Medicina/métodos , Cardiología/educación , Femenino , Masculino , Encuestas y Cuestionarios , Evaluación Educacional , Internado y Residencia
2.
J Arrhythm ; 40(4): 982-990, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39139869

RESUMEN

Background: Diagnosis of Brugada syndrome (BrS) may be established by exposing a Type 1 Brugada pattern using a sodium channel blocker. Data on the outcomes of different patient populations with drug-induced Type 1 Brugada pattern are limited. The present study reports on the characteristics and outcome of subjects with ajmaline induced Type 1 Brugada pattern. Methods: A multicenter retrospective study including all consecutive cases of ajmaline-induced Type 1 Brugada pattern from seven centers. Results: A total of 260 patients (69.9% males, mean age 43.4 ± 13.5) were included. Additional characteristics included history of syncope (n = 56, 21.5%), family history of BrS (n = 58, 22.3%) or sudden cardiac death (n = 47, 18.1%) and ventricular fibrillation (n = 3, 1.2%). Patients were divided into those meeting current diagnostic criteria for drug-induced BrS (DIBrS) and compared to the drug-induced Brugada pattern (DIBrECG). Females were significantly overrepresented in the DIBrS group (n = 50, 40% vs. n = 29, 21.5%, p = .001). A significantly higher prevalence of type 2/3 Brugada ECG at baseline was found in the DIBrECG group (n = 108, 80.8% vs. n = 75, 60% in the DIBrS, p = .026). During a median follow up of three (IQR 1.50-5.32) years, a single event of significant arrhythmia occurred in the DIBrS group. Conclusion: Less than half of subjects with ajmaline-induced Brugada pattern met current criteria for BrS. These individuals had very low rate of adverse outcomes during a follow up of 3 years, irrespective of the indication for the test or eligibility for the BrS diagnosis.

4.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38875490

RESUMEN

AIMS: Superior vena cava (SVC) isolation during atrial fibrillation catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: One hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (±posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phrenic nerve palsy at the end of the procedure and at hospital discharge. Transient high-degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Vena Cava Superior , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Vena Cava Superior/cirugía , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Prospectivos , Venas Pulmonares/cirugía , Catéteres Cardíacos , Diseño de Equipo , Nervio Frénico/lesiones
5.
Heart Rhythm ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38810921

RESUMEN

BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.

6.
J Interv Card Electrophysiol ; 67(5): 1241-1246, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38561572

RESUMEN

BACKGROUND: Permanent pacing is often required following valve intervention (either surgical or percutaneous); however, tricuspid interventions pose specific challenges to conventional pacing. Therefore, leadless pacemaker (LP) implantation may be the preferred strategy when permanent pacing is required after tricuspid valve intervention. PURPOSE: To report periprocedural outcomes and follow-up of patients undergoing implantation of a LP system following tricuspid valve interventions. METHODS: Patients with previous tricuspid valve intervention at the time of attempted implantation of a LP (MicraTM, Medtronic, Minneapolis, MN, USA) were included. RESULTS: Between 2019 and 2022, 40 patients underwent LP implantations following tricuspid interventions in 5 large tertiary centers. The mean age was 68.9 ± 13.7 years, and 48% patients were male. The indication for pacing was as following: AVB in 27 (68%) patients, AF with slow ventricular response in 10 (25%) patients, and refractory rapid atrial fibrillation (AF) referred to AV junction ablation in 3 (7%) patients. Most of the patients received Micra VR (78%). The procedure was successful in all patients. The mean procedural time is 58 ± 32 min, and the median fluoroscopy time is 7.5 min. Electrical parameters were within normal range (threshold: 1.35 ± 1.2 V@0.24 ms, impedance: 772 ± 245 Ohm, R-wave: 6.9 ± 5.4 mV). No acute complications were observed. During a mean follow-up of 10 months, electrical parameters remained stable, and 4 deaths were occurred (not related to the procedure). CONCLUSION: A LP is a safe and efficient option following tricuspid valve interventions.


Asunto(s)
Estudios de Factibilidad , Marcapaso Artificial , Válvula Tricúspide , Humanos , Masculino , Femenino , Anciano , Válvula Tricúspide/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Estudios Retrospectivos
9.
JMIR Form Res ; 7: e47876, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37874630

RESUMEN

BACKGROUND: As strength sports gain popularity, there is a growing need to explore the impact of sustained strength training on cardiac biventricular structure and function, an area that has received less attention compared to the well-established physiological cardiac adaptation to endurance training. OBJECTIVE: This study aims to implement a 20-week high-intensity strength training program to enhance maximal muscle strength and evaluate its impact on cardiac biventricular adaptation in healthy, untrained men. METHODS: A total of 27 healthy and untrained young men (mean age 22.8, SD 3.2 years) participated in a strength training program designed to increase muscle strength. The training program involved concentric, eccentric, and isometric exercise phases, conducted over a consecutive 20-week time frame with a frequency of 3 weekly training sessions. Participants were evaluated before and after 12 and 20 weeks of training through body composition analysis (bioelectrical impedance), a 12-lead resting electrocardiogram, 3D transthoracic echocardiography, cardiopulmonary exercise testing, and muscle isokinetic dynamometry. The progression of strength training loads was guided by 1-repetition maximum (RM) testing during the training program. RESULTS: Of the initial cohort, 22 participants completed the study protocol. No injuries were reported. The BMI (mean 69.8, SD 10.8 kg/m² vs mean 72, SD 11 kg/m²; P=.72) and the fat mass (mean 15.3%, SD 7.5% vs mean 16.5%, SD 7%; P=.87) remained unchanged after training. The strength training program led to significant gains in 1-RM exercise testing as early as 4 weeks into training for leg extension (mean 69.6, SD 17.7 kg vs mean 96.5, SD 31 kg; P<.001), leg curl (mean 43.2, SD 9.7 kg vs mean 52.8, SD 13.4 kg; P<.001), inclined press (mean 174.1, SD 41.1 kg vs mean 229.2, SD 50.4 kg; P<.001), butterfly (mean 26.3, SD 6.2 kg vs mean 32.5, SD 6.6 kg; P<.001), and curl biceps on desk (mean 22.9, SD 5.2 kg vs mean 29.6, SD 5.2 kg; P<.001). After 20 weeks, the 1-RM leg curl, bench press, pullover, butterfly, leg extension, curl biceps on desk, and inclined press showed significant mean percentage gains of +40%, +41.1%, +50.3%, +63.5%, +80.1%, +105%, and +106%, respectively (P<.001). Additionally, the isokinetic evaluation confirmed increases in maximal strength for the biceps (+9.2 Nm), triceps (+11.6 Nm), quadriceps (+46.8 Nm), and hamstrings (+25.3 Nm). In this paper, only the training and muscular aspects are presented; the cardiac analysis will be addressed separately. CONCLUSIONS: This study demonstrated that a short-term high-intensity strength training program was successful in achieving significant gains in muscle strength among previously untrained young men. We intend to use this protocol to gain a better understanding of the impact of high-intensity strength training on cardiac physiological remodeling, thereby providing new insights into the cardiac global response in strength athletes. TRIAL REGISTRATION: ClinicalTrials.gov NCT04187170; https://clinicaltrials.gov/study/NCT04187170.

10.
Respir Med Res ; 84: 101025, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37734232

RESUMEN

BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.


Asunto(s)
Marcapaso Artificial , Síndromes de la Apnea del Sueño , Anciano , Humanos , Sueño , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia , Polisomnografía , Algoritmos
11.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37558371

RESUMEN

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Transposición de los Grandes Vasos , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Estudios de Cohortes , Resultado del Tratamiento , Estudios Retrospectivos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/terapia
12.
Front Cardiovasc Med ; 10: 1161017, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180807

RESUMEN

Objectives: The objectives of this study were to examine left atrial (LA) function and compliance using two-dimensional (2D) strain analysis in adult patients with corrected Tetralogy of Fallot (c-ToF) and to investigate the relationships between LA function and patient characteristics, especially history of life-threatening arrhythmia (h-LTA). Methods: Fifty-one c-ToF patients (34 males; age, 39 ± 15 years; h-LTA, n = 13) were included in this retrospective monocenter study. In addition to a 2D standard echocardiography examination, 2D strain analysis was performed to assess left ventricular (LV) and LA functions, including peak-positive LA strain (LAS-reservoir function) and LA compliance [defined as the ratio LAS/(E/Ea)]. Results: Patients with h-LTA were older and exhibited a longer QRS duration. LV ejection fraction, LAS and LA compliance were significantly lower in the group of patients with h-LTA. Indexed LA and RA volumes, RV end-diastolic area was significantly higher and RV fractional area change significantly lower in the h-LTA group. LA compliance was the best echocardiographic predictor for h-LTA (AUC: 0.839; p < 0.001). Moderate inverted correlations were found between LA compliance and age and QRS duration. Among the echocardiographic parameters, LA compliance was moderately inversely correlated with RV end-diastolic area (r = -0.40, p = 0.01). Conclusion: We documented abnormal LAS and LA compliance values in adult c-ToF patients. Further study is needed to determine how best to incorporate LA strain, particularly LA compliance, into multiparametric predictive models for LTA in c-ToF patients.

14.
Arch Cardiovasc Dis ; 116(5): 265-271, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37179224

RESUMEN

BACKGROUND: Conduction system pacing (CSP) is an emerging and promising approach for physiological ventricular pacing. While data from randomized controlled trials are scarce, use of His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP) has increased in France. AIM: To perform a national snapshot survey for cardiac electrophysiologists to evaluate adoption of CSP in France. METHODS: An online survey, distributed to every senior cardiac electrophysiologist in France, was conducted in November 2022. RESULTS: A total of 120 electrophysiologists completed the survey. Eighty-three (69%) respondents reported experience in undertaking CSP procedures and 27 (23%) were planning to start performing CSP in the coming 2 years. The implantation techniques and criteria used for successful implantation differed significantly among operators. The most frequent indications for HBP and LBBAP were high-degree atrioventricular block with left ventricular ejection fraction (LVEF) < 40% (24 and 82%, respectively) or with LVEF ≥ 40% (27 and 74%, respectively), and after failure of a coronary sinus left ventricular lead (27 and 71%, respectively). The limitations respondents most frequently perceived when performing HBP were bad sensing/pacing parameters (45%), increased procedure duration (41%) and risk of lead dislodgement (30%). The most frequently perceived limitations to performing LBBAP were absence of guidelines or consensus (31%), lack of medical training (23%) and increased procedure duration (23%). CONCLUSIONS: Our national survey-based study supports wide adoption of CSP in France. CSP is currently used as a second-line approach for both antibradycardia and resynchronization indications, with important variations regarding implantation techniques and criteria for measuring success.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Humanos , Volumen Sistólico , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Función Ventricular Izquierda , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento
16.
Front Cardiovasc Med ; 10: 1099544, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37082453

RESUMEN

Objectives: We sought to assess the resumption of sport, exercise performances, and quality of life (QoL) in adults and children after surgical repair of anomalous coronary arteries originating from the opposite sinus (ACAOS). Materials and methods: Patients who underwent surgical repair for ACAOS between 2002 and 2022 were retrospectively identified. Information about sports activity and exercise performance based on metabolic equivalents of task (METs) calculated at the last exercise stress test, were collected. QoL was assessed using age-appropriate questionnaires (Paediatric QoL Inventory, cardiac module version 3.0 for patients <18 years; SF-36 QoL Inventory for adults). Patients' METS and patients' QoL-scores were compared to reference population using the Wilcoxon test. Results: 45 patients were enrolled (males 71%, adults 49%, anomalous right coronary 84%). Median age at surgery was 15 years; median follow-up after surgery was 2.3 years [4 months-12 years]. All post-operative exercise stress tests were normal, METs and VO2 max patients' values did not differ from healthy children or adults (Exercise intensity: 12.5 ± 4.7 vs. 13.4 ± 2 METS, p = 0.3; VO2 max: 43.6 ± 16.6 vs. 46.9 ± 7 ml/kg/min, p = 0.37). For adults, QoL-scores were similar between ACAOS patients and controls. For children, there was no significant difference between the study patients' scores and those of the reference population, except for physical appearance proxy-report (p = 0.02). Conclusion: In our study, the practice of sports, exercise stress testing and QoL were not adversely affected after ACAOS repair.

18.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36607529

RESUMEN

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Asunto(s)
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudios Transversales , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Electrocardiografía , Estimulación Cardíaca Artificial , Resultado del Tratamiento
19.
Front Cardiovasc Med ; 9: 998883, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36386348

RESUMEN

Background: Myocardial inflammation has been consistently associated with genetic arrhythmogenic cardiomyopathy (ACM) and it has been hypothesized that episodes mimicking acute myocarditis (AM) could represent early inflammatory phases of the disease. Objective: We evaluated the temporal association between recurrent acute myocarditis (RAM) episodes and the later diagnosis of a genetic ACM. Materials and methods: Between January 2012 and December 2021, patients with RAM and no previous cardiomyopathy were included (Recurrent Acute Myocarditis Registry, NCT04589156). A follow-up visit including clinical evaluation, resting and stress electrocardiogram, cardiac magnetic resonance imaging, and genetic testing was carried out. Endpoints of the study was the incidence of both ACM diagnosis criteria and ACM genetic mutation at the end of follow-up. Results: Twenty-one patients with RAM were included and follow-up was completed in 19/21 patients (90%). At the end of follow-up, 3.3 ± 2.9 years after the last AM episode, 14/21 (67%) patients with an ACM phenotype (biventricular: 10/14, 71%; left ventricular: 4/14, 29%) underwent genetic testing. A pathogenic or likely pathogenic mutation was found in 8/14 patients (57%), 5/8 in the Desmoplakin gene, 2/8 in the Plakophillin-2 gene, and 1/8 in the Titin gene. Family history of cardiomyopathy or early sudden cardiac death had a positive predictive value of 88% for the presence of an underlying genetic mutation in patients with RAM. Conclusion: RAM is a rare entity associated with the latter diagnosis of an ACM genetic mutation in more than a third of the cases. In those patients, RAM episodes represent early inflammatory phases of the disease. Including RAM episodes in ACM diagnosis criteria might allow early diagnosis and potential therapeutic interventions.

20.
Europace ; 24(12): 1952-1959, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36002951

RESUMEN

AIMS: Despite recent improvements, inappropriate shocks emitted by implanted subcutaneous implantable cardioverter defibrillators (S-ICDs) remain a challenge in 'real-life' practice. We aimed to study the pre-implant factors associated with inappropriate shocks for the latest generation of S-ICDs. METHODS AND RESULTS: Three-hundred patients implanted with the third-generation S-ICD system for primary or secondary prevention between January 2017 and March 2020 were included in this multicentre retrospective observational study. A follow-up of at least 6 months and pre-implant screening procedure data were mandatory for inclusion. During a mean follow-up of 22.8 (±11.4) months, 37 patients (12.3%) received appropriate S-ICD shock therapy, whereas 26 patients (8.7%) experienced inappropriate shocks (incidence 4.9 per 100 patient years). The total number of inappropriate shock episodes was 48, with nine patients experiencing multiple episodes. The causes of inappropriate shocks included supraventricular arrhythmias (34.6%) and cardiac (30.7%) or extra-cardiac noise (38.4%) oversensing. Using multivariate analysis, we explored the independent factors associated with inappropriate shocks. These were the availability of less than three sensing vectors during pre-implant screening [hazard ratio (HR), 0.33; 95% confidence interval (CI), 0.11-0.93; P = 0.035], low QRS/T wave ratio in Lead I (for a threshold <3; HR, 4.79; 95% CI, 2.00-11.49; P < 0.001), history of supraventricular tachycardia (HR, 8.67; 95% CI, 2.80-26.7; P < 0.001), and being overweight (body mass index > 25; HR, 2.66; 95% CI, 1.10-6.45; P = 0.03). CONCLUSION: Automatic pre-implant screening data are a useful quantitative predictor of inappropriate shocks. Electrocardiogram features should be taken into consideration along with other clinical factors to identify patients at high risk of inappropriate shocks.


Asunto(s)
Desfibriladores Implantables , Taquicardia Supraventricular , Humanos , Desfibriladores Implantables/efectos adversos , Taquicardia Supraventricular/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Estudios Retrospectivos , Electrocardiografía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA