Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BJOG ; 128(11): 1732-1743, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34165867

RESUMEN

OBJECTIVES: To evaluate uterine tamponade devices' effectiveness for atonic refractory postpartum haemorrhage (PPH) after vaginal birth and the effect of including them in institutional protocols. SEARCH STRATEGY: PubMed, EMBASE, CINAHL, LILACS, POPLINE, from inception to January 2021. STUDY SELECTION: Randomised and non-randomised comparative studies. OUTCOMES: Composite outcome including surgical interventions (artery ligations, compressive sutures or hysterectomy) or maternal death, and hysterectomy. RESULTS: All included studies were at high risk of bias. The certainty of the evidence was rated as very low to low. One randomised study measured the effect of the condom-catheter balloon compared with standard care and found unclear results for the composite outcome (relative risk [RR] 2.33, 95% CI 0.76-7.14) and hysterectomy (RR 4.14, 95% CI 0.48-35.93). Three comparative studies assessed the effect of including uterine balloon tamponade in institutional protocols. A stepped wedge cluster randomised controlled trial suggested an increase in the composite outcome (RR 4.08, 95% CI 1.07-15.58) and unclear results for hysterectomy (RR 4.38, 95% CI 0.47-41.09) with the use of the condom-catheter or surgical glove balloon. One non-randomised study showed unclear effects on the composite outcome (RR 0.33, 95% CI 0.11-1.03) and hysterectomy (RR 0.49, 95% CI 0.04-5.38) after the inclusion of the Bakri balloon. The second non-randomised study found unclear effects on the composite outcome (RR 0.95, 95% CI 0.32-2.81) and hysterectomy (RR 1.84, 95% CI 0.44-7.69) after the inclusion of Ebb or Bakri balloon. CONCLUSIONS: The effect of uterine tamponade devices for the management of atonic refractory PPH after vaginal delivery is unclear, as is the role of the type of device and the setting. TWEETABLE ABSTRACT: Unclear effects of uterine tamponade devices and their inclusion in institutional protocols for atonic refractory PPH after vaginal delivery.


Asunto(s)
Parto Obstétrico/efectos adversos , Técnicas Hemostáticas/instrumentación , Hemorragia Posparto/terapia , Taponamiento Uterino con Balón/instrumentación , Adulto , Parto Obstétrico/métodos , Femenino , Técnicas Hemostáticas/mortalidad , Humanos , Histerectomía/mortalidad , Histerectomía/estadística & datos numéricos , Ligadura/instrumentación , Mortalidad Materna , Hemorragia Posparto/mortalidad , Embarazo , Resultado del Tratamiento , Arteria Uterina/cirugía , Embolización de la Arteria Uterina/instrumentación , Embolización de la Arteria Uterina/mortalidad , Taponamiento Uterino con Balón/mortalidad , Vagina
2.
BJOG ; 123(3): 427-36, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26259689

RESUMEN

OBJECTIVE: To generate a global reference for caesarean section (CS) rates at health facilities. DESIGN: Cross-sectional study. SETTING: Health facilities from 43 countries. POPULATION/SAMPLE: Thirty eight thousand three hundred and twenty-four women giving birth from 22 countries for model building and 10,045,875 women giving birth from 43 countries for model testing. METHODS: We hypothesised that mathematical models could determine the relationship between clinical-obstetric characteristics and CS. These models generated probabilities of CS that could be compared with the observed CS rates. We devised a three-step approach to generate the global benchmark of CS rates at health facilities: creation of a multi-country reference population, building mathematical models, and testing these models. MAIN OUTCOME MEASURES: Area under the ROC curves, diagnostic odds ratio, expected CS rate, observed CS rate. RESULTS: According to the different versions of the model, areas under the ROC curves suggested a good discriminatory capacity of C-Model, with summary estimates ranging from 0.832 to 0.844. The C-Model was able to generate expected CS rates adjusted for the case-mix of the obstetric population. We have also prepared an e-calculator to facilitate use of C-Model (www.who.int/reproductivehealth/publications/maternal_perinatal_health/c-model/en/). CONCLUSIONS: This article describes the development of a global reference for CS rates. Based on maternal characteristics, this tool was able to generate an individualised expected CS rate for health facilities or groups of health facilities. With C-Model, obstetric teams, health system managers, health facilities, health insurance companies, and governments can produce a customised reference CS rate for assessing use (and overuse) of CS. TWEETABLE ABSTRACT: The C-Model provides a customized benchmark for caesarean section rates in health facilities and systems.


Asunto(s)
Cesárea/estadística & datos numéricos , Modelos Estadísticos , Adulto , Estudios Transversales , Femenino , Humanos , Internacionalidad , Embarazo , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA