Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Afr J Lab Med ; 13(1): 2339, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39228898

RESUMEN

Background: HIV testing remains an entry point into HIV care and treatment services. In 2007, Nigeria adopted and implemented a two-test rapid HIV testing algorithm of three HIV rapid test kits, following the sequence: Alere Determine (first test), UnigoldTM (second test), and STAT-PAK® as the tie-breaker. Sub-analysis of the 2018 Nigeria HIV/AIDS Indicator and Impact Survey data showed significant discordance between the first and second tests, necessitating an evaluation of the algorithm. This manuscript highlights lessons learnt from that evaluation. Intervention: A two-phased evaluation method was employed, including abstraction and analysis of retrospective HIV testing data from January 2017 to December 2019 from 24 selected sites supported by the United States President's Emergency Plan for AIDS Relief programme. A prospective evaluation of HIV testing was done among 2895 consecutively enrolled and consented adults, aged 15-64 years, accessing HIV testing services from three selected sites per state across the six geopolitical zones of Nigeria between July 2020 and September 2020. The prospective evaluation was performed both in the field and at the National Reference Laboratory under controlled laboratory conditions. Stakeholder engagements, strategic selection and training of study personnel, and integrated supportive supervision were employed to assure the quality of evaluation procedures and outcomes. Lessons learnt: The algorithm showed higher sensitivity and specificity in the National Reference Laboratory compared with the field. The approaches to quality assurance were integral to the high-quality study outcomes. Recommendations: We recommend comparison of testing algorithms under evaluation against a gold standard. What this study adds: This study provides context-specific considerations in using World Health Organization recommendations to evaluate the Nigerian national HIV rapid testing algorithm.

2.
J Clin Virol Plus ; 3(1): 100139, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36683611

RESUMEN

Objectives: Determining an accurate estimate of SARS-CoV-2 seroprevalence has been challenging in African countries where malaria and other pathogens are endemic. We compared the performance of one single-antigen assay and three multi-antigen SARS-CoV-2 IgG assays in a Nigerian population endemic for malaria. Methods: De-identified plasma specimens from SARS-CoV-2 RT-PCR positive, dried blood spot (DBS) SARS-CoV-2 RT-PCR positive, and pre-pandemic negatives were used to evaluate the performance of the four SARS-CoV-2 assays (Tetracore, SARS2MBA, RightSign, xMAP). Results: Results showed higher sensitivity with the multi-antigen (81% (Tetracore), 96% (SARS2MBA), 85% (xMAP)) versus the single-antigen (RightSign (64%)) SARS-CoV-2 assay. The overall specificities were 98% (Tetracore), 100% (SARS2MBA and RightSign), and 99% (xMAP). When stratified based on <15 days to ≥15 days post-RT-PCR confirmation, the sensitivities increased from 75% to 88.2% for Tetracore; from 93% to 100% for the SARS2MBA; from 58% to 73% for RightSign; and from 83% to 88% for xMAP. With DBS, there was no positive increase after 15-28 days for the three assays (Tetracore, SARS2MBA, and xMAP). Conclusion: Multi-antigen assays performed well in Nigeria, even with samples with known malaria reactivity, and might provide more accurate measures of COVID-19 seroprevalence and vaccine efficacy.

3.
PLOS Glob Public Health ; 2(11): e0001077, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962660

RESUMEN

Human Immunodeficiency Virus (HIV) diagnosis remains the gateway to HIV care and treatment. However, due to changes in HIV prevalence and testing coverage across different geopolitical zones, it is crucial to evaluate the national HIV testing algorithm as false positivity due to low prevalence could be detrimental to both the client and the service delivery. Therefore, we evaluated the performance of the national HIV rapid testing algorithm using specimens collected from multiple HIV testing services (HTS) sites and compared the results from different HIV prevalence levels across the six geopolitical zones of Nigeria. The evaluation employed a dual approach, retrospective, and prospective. The retrospective evaluation focused on a desktop review of program data (n = 492,880) collated from patients attending routine HTS from six geopolitical zones of Nigeria between January 2017 and December 2019. The prospective component utilized samples (n = 2,895) collected from the field at the HTS and tested using the current national serial HIV rapid testing algorithm. These samples were transported to the National Reference Laboratory (NRL), Abuja, and were re-tested using the national HIV rapid testing algorithm and HIV-1/2 supplementary assays (Geenius to confirm positives and resolve discordance and multiplex assay). The retrospective component of the study revealed that the overall proportion of HIV positives, based on the selected areas, was 5.7% (28,319/492,880) within the study period, and the discordant rate between tests 1 and 2 was 1.1%. The prospective component of the study indicated no significant differences between the test performed at the field using the national HIV rapid testing algorithm and the re-testing performed at the NRL. The comparison between the test performed at the field using the national HIV rapid testing algorithm and Geenius HIV-1/2 supplementary assay showed an agreement rate of 95.2%, while that of the NRL was 99.3%. In addition, the comparison of the field results with HIV multiplex assay indicated a sensitivity of 96.6%, the specificity of 98.2%, PPV of 97.0%, and Kappa Statistic of 0.95, and that of the NRL with HIV multiplex assay was 99.2%, 99.4%, 99.0%, and 0.99, respectively. Results show that the Nigeria national serial HIV rapid testing algorithm performed very well across the target settings. However, the algorithm's performance in the field was lower than the performance outcomes under a controlled environment in the NRL. There is a need to target testers in the field for routine continuous quality improvement implementation, including refresher trainings as necessary.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA