Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
3.
Cardiovasc Intervent Radiol ; 24(5): 329-31, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11815839

RESUMEN

Spontaneous dissection of the superior mesenteric artery (SMA) is a rare occurrence, especially when not associated with aortic dissection [1]. Currently, only 28 cases appear to have been reported. Due to the scarcity of cases in the literature, the natural history of isolated, spontaneous SMA dissection is unclear. CT has been reported to be useful for the initial diagnosis of SMA dissection [2-5]. We present two recent cases of spontaneous SMA dissection in which enhanced spiral CT was instrumental in following the disease process and guiding clinical decision making.


Asunto(s)
Disección Aórtica/diagnóstico por imagen , Arteria Mesentérica Superior/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Disección Aórtica/patología , Humanos , Masculino , Arteria Mesentérica Superior/patología , Persona de Mediana Edad , Rotura Espontánea
4.
J Vasc Interv Radiol ; 11(9): 1143-52, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11041470

RESUMEN

PURPOSE: To compare the frequency and extent of pulmonary embolism (PE) occurring during pulse-spray pharmacomechanical thrombolysis (PSPMT) of clotted hemodialysis grafts with use of either urokinase (UK) or heparinized saline (HS). Postintervention primary patency and complication rates were compared for each method of thrombolysis. METHODS AND MATERIALS: Twenty-seven patients were enrolled in this prospective, randomized, double-blind study evaluating PE with two PSPMT agents. The doses of heparin were similar between groups. The only variable was that one group of patients received UK and the other received HS. In two cases, the venous anastomosis could not be crossed. Eleven patients were treated with UK and 14 with HS. Nuclear medicine perfusion lung scans were performed before treatment and after graft declotting procedures. Lung perfusion was quantified to 10% of a pulmonary segment (0 = normal perfusion, 1 = segmental perfusion defect), with nine segments counted for each lung. RESULTS: Baseline nuclear medicine perfusion lung scan results were abnormal (> or = 20% segmental perfusion defect) in 19 patients (70.4%). New PE (one or more pulmonary segments) occurred in two patients treated with UK (18.2%) and nine patients treated with HS (64.3%; P = .04). All cases of PE were asymptomatic. Quantitative global pulmonary perfusion analyses revealed that treatment with UK improved flow to 0.2 +/- 2.0 pulmonary segments, whereas treatment with HS decreased perfusion to 1.0 +/- 1.7 segments (P = .16, NS). Although postintervention primary patency rates were similar according to life-table analysis (P = .76, NS), complication rates were higher with use of HS (n = 4, 28.6%) than with use of UK (n = 2, 18.2%) (P = .6, NS). CONCLUSIONS: All PE were asymptomatic during PSPMT, but treatment with UK reduced the rate of PE and tended to result in smaller defects in lung scan results. Most patients undergoing hemodialysis have abnormal baseline perfusion scan results, but PSPMT with UK improved many of them. The postintervention primary patency rates were similar between groups, but complications were more frequent after treatment with HS.


Asunto(s)
Prótesis Vascular/efectos adversos , Fibrinolíticos/efectos adversos , Oclusión de Injerto Vascular/tratamiento farmacológico , Heparina/efectos adversos , Embolia Pulmonar/etiología , Diálisis Renal/instrumentación , Terapia Trombolítica/efectos adversos , Activador de Plasminógeno de Tipo Uroquinasa/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Derivación Arteriovenosa Quirúrgica/efectos adversos , Método Doble Ciego , Femenino , Humanos , Tablas de Vida , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Embolia Pulmonar/inducido químicamente , Embolia Pulmonar/prevención & control , Radiografía Intervencional , Resultado del Tratamiento , Grado de Desobstrucción Vascular
5.
AJR Am J Roentgenol ; 175(2): 529-32, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10915708

RESUMEN

OBJECTIVE: The purpose of this study was to assess the efficacy of repeated pulsed spray pharmacomechanical thrombolysis for salvage of early rethrombosis of hemodialysis grafts and to identify factors that predict successful outcome. MATERIALS AND METHODS: Thirty-four patients with initial successful thrombolysis were referred for repeated thrombolysis because of early rethrombosis. Repeated thrombolysis occurred within 1 month of initial thrombolysis. Technical success and patency rates were calculated. Causes of graft thrombosis and procedural modifications were analyzed. RESULTS: The 39 rethrombosed grafts were successfully treated using pharmacomechanical thrombolysis, and patients underwent subsequent hemodialysis. The underlying flow-limiting stenoses were treated with balloon angioplasty using a larger balloon (41%), a same-size angioplasty balloon (18%), stent placement (15%), or increased anticoagulation (5%). A new stenosis location was discovered in 18%. Mean primary patency was 80.9 days (2.6 months) and secondary patency was 235.4 days (7.8 months). With life table analysis, 1-, 3-, 6-, and 12-month primary patency rates were 72%, 31%, 23%, and 15%, and secondary patency rates were 77%, 62%, 51%, and 31%, respectively. Graft patency rates in our study were compared with our institutional historic graft patency rates, with no significant difference noted (p = 0.76). No major procedural complications occurred. CONCLUSION: Adequate technical success and patency rates for pharmacomechanical thrombolysis occur even for hemodialysis grafts that rethrombose within 1 month. After thrombolysis, aggressive search for and treatment of additional stenoses are warranted.


Asunto(s)
Prótesis Vascular/efectos adversos , Diálisis Renal , Terapia Trombolítica/métodos , Trombosis/tratamiento farmacológico , Trombosis/etiología , Humanos , Recurrencia , Inducción de Remisión , Estudios Retrospectivos , Factores de Tiempo , Grado de Desobstrucción Vascular
6.
J Vasc Interv Radiol ; 11(6): 10 p following 805, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10877410

RESUMEN

PURPOSE: To evaluate the usefulness of information provided by three-dimensional ultrasound (3D US) and to determine whether 3D US decreased the number of passes required to obtain portal vein (PV) access during creation of transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS: Intermittent 3D US volume acquisitions were obtained during creation of TIPS in 20 patients. Useful information provided by 3D US was tabulated. The number of passes required to achieve PV access was recorded and results were compared retrospectively to 25 patients who underwent TIPS without 3D US. RESULTS: 3D US documented that the operator's opinion of which hepatic vein had been selected was incorrect in nine patients (45%), detected unfavorable PV anatomy that required modification of equipment or technique in seven patients (35%), permitted estimation of the trajectory required to access the targeted PV in all patients (100%), assisted in selecting the optimal point along the hepatic vein for origination of the needle pass in 11 patients (55%), allowed avoidance of a large hepatocellular carcinoma in one patient (5%), and confirmed that access into the main PV was intrahepatic in four patients (20%). The mean number of needle passes decreased from 10.4 in the historic control group to 4.6 in the 3D US group (P = .0001). CONCLUSION: 3D US provided imaging information that detected technical errors and altered anatomy, and provided positional and directional information to significantly improve needle pass efficiency.


Asunto(s)
Monitoreo Intraoperatorio/métodos , Vena Porta/diagnóstico por imagen , Derivación Portosistémica Intrahepática Transyugular/métodos , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Várices Esofágicas y Gástricas/diagnóstico por imagen , Várices Esofágicas y Gástricas/cirugía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Vena Porta/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados
8.
J Vasc Interv Radiol ; 11(5): 611-21, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10834493

RESUMEN

PURPOSE: To evaluate the usefulness of information provided by three-dimensional ultrasound (3D US) and to determine whether 3D US decreased the number of passes required to obtain portal vein (PV) access during creation of transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS: Intermittent 3D US volume acquisitions were obtained during creation of TIPS in 20 patients. Useful information provided by 3D US was tabulated. The number of passes required to achieve PV access was recorded and results were compared retrospectively to 25 patients who underwent TIPS without 3D US. RESULTS: 3D US documented that the operator's opinion of which hepatic vein had been selected was incorrect in nine patients (45%), detected unfavorable PV anatomy that required modification of equipment or technique in seven patients (35%), permitted estimation of the trajectory required to access the targeted PV in all patients (100%), assisted in selecting the optimal point along the hepatic vein for origination of the needle pass in 11 patients (55%), allowed avoidance of a large hepatocellular carcinoma in one patient (5%), and confirmed that access into the main PV was intrahepatic in four patients (20%). The mean number of needle passes decreased from 10.4 in the historic control group to 4.6 in the 3D US group (P = .0001). CONCLUSION: 3D US provided imaging information that detected technical errors and altered anatomy, and provided positional and directional information to significantly improve needle pass efficiency.


Asunto(s)
Imagenología Tridimensional , Vena Porta/diagnóstico por imagen , Derivación Portosistémica Intrahepática Transyugular , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Várices Esofágicas y Gástricas/cirugía , Femenino , Fluoroscopía , Venas Hepáticas/diagnóstico por imagen , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Vena Porta/anatomía & histología , Estadísticas no Paramétricas
11.
J Vasc Interv Radiol ; 8(6): 1029-37, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9399474

RESUMEN

PURPOSE: A comparison of tilting, caval coverage, asymmetry, and insertion problems with the over-the-wire stainless-steel and titanium versions of the Greenfield filter. MATERIALS AND METHODS: The study compared 104 stainless-steel and 141 titanium Greenfield inferior vena cava (IVC) filter insertions. The angle the sheath and deployed filter made relative to the cava, as well as filter strut distribution, were determined from spot films. The proportionate caval coverage was computed from the cavogram (anteroposterior projection). Mean filter tilts, subgrouped by insertion site, and caval coverage were compared with the Student t test, whereas strut patterns were analyzed with a contingency table. RESULTS: The filter caval and sheath caval angles correlated. The filter caval angles varied with insertion site, but were lowest with a right jugular approach. Caval coverage was identical with both designs. The stainless-steel version resulted in a more uniform distribution of struts in comparison with the titanium version. The incidence of insertion problems was not significantly different between the filter types. CONCLUSIONS: While IVC filter tilting was not improved with the newer design, the pattern of struts was more uniformly symmetric with the stainless-steel device. The right jugular insertion site was associated with the lowest filter caval angles and the most symmetric pattern of struts.


Asunto(s)
Filtros de Vena Cava , Vena Cava Inferior , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Acero Inoxidable , Titanio
14.
J Vasc Interv Radiol ; 7(6): 907-15, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8951759

RESUMEN

PURPOSE: To determine whether acute cervical spine injury represents a risk factor for complications from prophylactic placement of current generation Greenfield inferior vena cava (IVC) filters. MATERIALS AND METHODS: A retrospective chart review performed during a 7-year period identified 11 patients with acute cervical spinal cord injuries who underwent prophylactic Greenfield IVC filter insertion. Specific complications evaluated included symptomatic pulmonary embolism (PE), migration, filter base diameter changes, caval perforation, and thrombosis. The amount of migration and changes in filter base dimension were compared statistically with a control population of IVC filter patients (n = 16) without cervical spine injuries. RESULTS: Filter migration (> 10 mm) was the most common complication (46%). Migration usually is caudally directed (64%), may occur early (36% moved > 10 mm within a 30-day period), and is often asymptomatic. The prevalence of filter migration greater than 30 mm was 27%. The average amount of migration for the subpopulation under study was greater than that seen with the control population (P < .05). No statistically significant change in filter base size occurred. The study population also had rates of PE (9%-18%), caval perforation (9%), and IVC thrombus formation (18%) that were higher than the rates in historical controls. The majority of patients with these complications received vigorous pulmonary toilet (46%), including "quad coughs" or cardiopulmonary resuscitation (18%). CONCLUSIONS: Acute cervical spinal cord injury and the associated supportive care may be associated with an increased risk for caudal IVC filter migration, IVC perforation, caval thrombosis, and PE.


Asunto(s)
Migración de Cuerpo Extraño/epidemiología , Embolia Pulmonar/epidemiología , Traumatismos de la Médula Espinal/complicaciones , Trombosis/epidemiología , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior/lesiones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Masculino , Prevalencia , Embolia Pulmonar/prevención & control , Estudios Retrospectivos , Factores de Riesgo , Traumatismos de la Médula Espinal/epidemiología
16.
Radiology ; 199(3): 653-7, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8637982

RESUMEN

PURPOSE: To determine the value of a hemodialysis graft surveillance program in reducing the incidence of graft thrombosis and prolonging graft patency by means of early detection and percutaneous transluminal angioplasty (PTA) of graft-related stenoses. MATERIALS AND METHODS: For 4-1/2 years, routine graft examination and measurement of several dialysis parameters were used to identify 106 cases of suspected graft dysfunction in 57 patients (56 men, one woman; aged 27-76 years). Graft-related stenoses detected with angiography were treated with PTA. RESULTS: Abnormal physical examination findings were the most common sole indication of graft dysfunction. Of the 106 cases referred for angiographic evaluation, 97 (92%) had at least one lesion. PTA was successful in 88 of 90 treated cases. The primary patency rates at 1 year were 16% for arteriovenous fistulas (AVFs) and 23% for polytetrafluoroethylene (PTFE) grafts. Early detection of stenoses by means of surveillance and repeated PTA enabled 1-year primary assisted patency rates of 67% for AVFs and 68% for PTFE grafts. The incidence of graft thrombosis fell from 48% in 1988 to 17% in 1994 (P < .001). CONCLUSION: The hemodialysis graft surveillance program resulted in a statistically significant reduction in the incidence of graft thrombosis. Although primary patency rates after PTA were low, repeated PTA of detected stenoses allowed good primary assisted patency rates.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/efectos adversos , Oclusión de Injerto Vascular/diagnóstico por imagen , Vigilancia de la Población , Diálisis Renal , Trombosis/epidemiología , Adulto , Anciano , Angiografía de Substracción Digital , Angioplastia Coronaria con Balón , Prótesis Vascular , Femenino , Antebrazo/irrigación sanguínea , Oclusión de Injerto Vascular/terapia , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Trombosis/prevención & control
17.
J Vasc Interv Radiol ; 7(2): 241-5, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-9007804

RESUMEN

PURPOSE: To assess the efficacy and safety of percutaneous catheter drainage combined with alcohol sclerosis in the treatment of postoperative lymphoceles. PATIENTS AND METHODS: Thirteen patients with 14 postoperative symptomatic lymphoceles were treated. Drainage catheters were inserted under ultrasound (n = 13) or computed tomographic (n = 1) guidance. Lymphocele sclerosis was performed by instilling 10-100 mL of absolute alcohol into the lymphocele cavity and aspirating the alcohol after 30 minutes. Sclerosis sessions were carried out one to three times per day, usually three times per week. Catheter sinograms were obtained and prophylactic antibiotics administered. Imaging was repeated if symptoms or signs of recurrence developed. RESULTS: Successful drainage and sclerosis were achieved in all 13 patients. One patient with a recurrence was successfully treated with repeated drainage and alcohol ablation. No adverse effects of alcohol instillation were seen. The mean duration of catheterization was 36 days (range, 17-65 days; median, 30 days). CONCLUSION: Percutaneous drainage combined with alcohol ablation is a safe and effective treatment of postoperative lymphoceles.


Asunto(s)
Drenaje/métodos , Etanol/uso terapéutico , Linfocele/terapia , Complicaciones Posoperatorias/terapia , Escleroterapia/métodos , Adulto , Cateterismo , Femenino , Humanos , Linfocele/diagnóstico por imagen , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Radiografía , Ultrasonografía
18.
Radiology ; 196(3): 697-701, 1995 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7644631

RESUMEN

PURPOSE: To determine the cause of symptoms and efficacy of transcatheter therapy in a series of patients with dialysis grafts and hand pain referred for arteriography. MATERIALS AND METHODS: Thirteen patients with 14 hemodialysis grafts underwent arteriography for possible hand ischemia. The sites of proximal graft anastomosis were the distal radial artery (n = 6) and the mid- to distal brachial artery (n = 6). Transcatheter therapy was performed via the graft or by antegrade brachical puncture. RESULTS: The cause of symptoms was ischemia from obstructive arterial disease in seven cases (three with superimposed steal), graft steal alone in three, ischemic monomelic neuropathy in two, and carpal tunnel syndrome in two. Five arterial stenoses were treated with angioplasty, with improvement or resolution of symptoms in four patients. CONCLUSION: In this group, symptoms were usually the result of inflow or outflow arterial disease, alone or in combination with graft steal. Transcatheter therapy (angioplasty or embolization) is effective in selected cases.


Asunto(s)
Prótesis Vascular/efectos adversos , Catéteres de Permanencia/efectos adversos , Mano/irrigación sanguínea , Isquemia/diagnóstico por imagen , Isquemia/etiología , Diálisis Renal/instrumentación , Adulto , Anciano , Anastomosis Quirúrgica , Angioplastia de Balón , Arteriopatías Oclusivas/complicaciones , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/terapia , Arteria Braquial/diagnóstico por imagen , Arteria Braquial/cirugía , Síndrome del Túnel Carpiano/complicaciones , Embolización Terapéutica , Femenino , Estudios de Seguimiento , Mano/inervación , Humanos , Isquemia/terapia , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso Periférico/complicaciones , Punciones , Arteria Radial/diagnóstico por imagen , Arteria Radial/cirugía , Radiografía , Flujo Sanguíneo Regional , Estudios Retrospectivos
19.
AJR Am J Roentgenol ; 164(6): 1495-500; discussion 1501-3, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7754901

RESUMEN

OBJECTIVE: Pulse-spray pharmacomechanical thrombolysis is an evolving method for the treatment of vascular occlusions in which a highly concentrated fibrinolytic agent is injected as a high-pressure spray directly into thrombus. The purpose of this retrospective study was to analyze our long-term experience with this technique for the treatment of clotted hemodialysis grafts and to compare the efficacy and safety of the original and current methods. SUBJECTS AND METHODS: Over 6 years, 284 cases of dialysis graft thrombosis were considered suitable for treatment with pulse-spray thrombolysis. The original technique involved the injection of highly concentrated urokinase directly into a clot through two crisscross catheters with multiple side holes. The current technique includes early fragmentation of residual clot with a balloon catheter, intrathrombic injection of heparin, mechanical treatment of a lysis-resistant clot at the arterial anastomosis, and routine administration of aspirin. After thrombolysis, underlying obstructions were treated with balloon angioplasty, atherectomy, or stents. The technical success, immediate clinical success, and frequency of complications for the entire population were analyzed. In addition, the results for 36 cases treated with the original technique were compared with the results for 37 recent cases treated with the current technique. RESULTS: Of 284 cases considered suitable for treatment, thrombolysis was not done in eight cases because the venous anastomosis could not be crossed. Thrombolysis was discontinued in two cases because of extravasation of contrast material. The technical success for all grafts considered for treatment was 96%; 92% of treated grafts remained patent for at least 24 hr. Major complications occurred in 1% of cases, and minor complications occurred in 9% of cases. The clinical efficacies of the original and current techniques were 86% and 92%, respectively. The mean thrombolytic agent infusion time was reduced from 44 +/- 20 min to 23 +/- 13 min (p < .001). The overall procedure time for the recently treated subgroup was 67 +/- 26 min. There was no significant difference in the frequencies of major and minor complications between the treatment subgroups. CONCLUSION: Pulse-spray pharmacomechanical thrombolysis is a reliable, rapid, and safe method for recanalization of occluded dialysis grafts. The current technique has been proven as safe and effective as the original technique but offers the advantage of a significant reduction in the time required for the infusion of thrombolytic agent.


Asunto(s)
Angioplastia de Balón , Prótesis Vascular , Oclusión de Injerto Vascular/terapia , Diálisis Renal , Terapia Trombolítica/métodos , Trombosis/terapia , Anastomosis Quirúrgica , Aspirina/administración & dosificación , Cateterismo , Oclusión de Injerto Vascular/tratamiento farmacológico , Heparina/uso terapéutico , Humanos , Radiografía Intervencional , Estudios Retrospectivos , Terapia Trombolítica/efectos adversos , Trombosis/tratamiento farmacológico , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación , Activador de Plasminógeno de Tipo Uroquinasa/uso terapéutico
20.
Adv Ren Replace Ther ; 2(1): 52-9, 1995 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-7614337

RESUMEN

Prolonging the life of vascular access sites is one of the most pressing problems facing the nephrology team in the ongoing care of chronic hemodialysis patients. Thus, the ability to salvage a failing vascular access is important in any circumstance, but salvage is particularly critical in medically complicated situations. The following case presents just such a situation, one in which available access sites were limited and in which salvaging the function of a local access site obviated the need for major surgical intervention for more than 4 years. This example shows the efficacy of nonsurgical thrombolysis and the place of vascular radiology in the long-term preservation of access patency and follow-up care.


Asunto(s)
Angiografía , Angioplastia , Catéteres de Permanencia/efectos adversos , Diálisis Renal/instrumentación , Terapia Trombolítica , Anciano , Humanos , Masculino , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA