Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Braz J Med Biol Res ; 52(7): e8585, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31314854

RESUMEN

Atelectasis and inadequate oxygenation in lung donors is a common problem during the retrieval of these organs. Nevertheless, the use of high positive end-expiratory pressure (PEEP) is not habitual during procedures of lung retrieval. Twenty-one Sprague-Dawley male consanguineous rats were used in the study. The animals were divided into 3 groups according to the level of PEEP used: low (2 cmH2O), moderate (5 cmH2O), and high (10 cmH2O). Animals were ventilated with a tidal volume of 6 mL/kg. Before lung removal, the lungs were inspected for the presence of atelectasis. When atelectasis was detected, alveolar recruitment maneuvers were performed. Blood gasometric analysis was performed immediately. Finally, the lungs were retrieved, weighed, and submitted to histological analysis. The animals submitted to higher PEEP showed higher levels of oxygenation with the same tidal volumes PO2=262.14 (PEEP 2), 382.4 (PEEP 5), and 477.0 (PEEP 10). The occurrence of atelectasis was rare in animals with a PEEP of 10 cmH2O, which therefore required less frequent recruitment maneuvers (need for recruitment: PEEP 2=100%, PEEP 5 =100%, and PEEP 10=14.3%). There was no change in hemodynamic stability, occurrence of pulmonary edema, or other histological injuries with the use of high PEEP. The use of high PEEP (10 cmH2O) was feasible and probably a beneficial strategy for the prevention of atelectasis and the optimization of oxygenation during lung retrieval. Clinical studies should be performed to confirm this hypothesis.


Asunto(s)
Trasplante de Pulmón/métodos , Respiración con Presión Positiva/métodos , Atelectasia Pulmonar/rehabilitación , Intercambio Gaseoso Pulmonar/fisiología , Volumen de Ventilación Pulmonar/fisiología , Animales , Masculino , Modelos Animales , Atelectasia Pulmonar/fisiopatología , Ratas , Ratas Sprague-Dawley
2.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;52(7): e8585, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1011588

RESUMEN

Atelectasis and inadequate oxygenation in lung donors is a common problem during the retrieval of these organs. Nevertheless, the use of high positive end-expiratory pressure (PEEP) is not habitual during procedures of lung retrieval. Twenty-one Sprague-Dawley male consanguineous rats were used in the study. The animals were divided into 3 groups according to the level of PEEP used: low (2 cmH2O), moderate (5 cmH2O), and high (10 cmH2O). Animals were ventilated with a tidal volume of 6 mL/kg. Before lung removal, the lungs were inspected for the presence of atelectasis. When atelectasis was detected, alveolar recruitment maneuvers were performed. Blood gasometric analysis was performed immediately. Finally, the lungs were retrieved, weighed, and submitted to histological analysis. The animals submitted to higher PEEP showed higher levels of oxygenation with the same tidal volumes PO2=262.14 (PEEP 2), 382.4 (PEEP 5), and 477.0 (PEEP 10). The occurrence of atelectasis was rare in animals with a PEEP of 10 cmH2O, which therefore required less frequent recruitment maneuvers (need for recruitment: PEEP 2=100%, PEEP 5 =100%, and PEEP 10=14.3%). There was no change in hemodynamic stability, occurrence of pulmonary edema, or other histological injuries with the use of high PEEP. The use of high PEEP (10 cmH2O) was feasible and probably a beneficial strategy for the prevention of atelectasis and the optimization of oxygenation during lung retrieval. Clinical studies should be performed to confirm this hypothesis.


Asunto(s)
Animales , Masculino , Ratas , Atelectasia Pulmonar/rehabilitación , Intercambio Gaseoso Pulmonar/fisiología , Volumen de Ventilación Pulmonar/fisiología , Respiración con Presión Positiva/métodos , Trasplante de Pulmón/métodos , Atelectasia Pulmonar/fisiopatología , Ratas Sprague-Dawley , Modelos Animales
3.
Acta Crystallogr B ; 61(Pt 1): 11-6, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15659852

RESUMEN

Single microcrystals of the new compound samarium dimanganese germanium oxide, SmMn2GeO7, were grown using the flux method in a double spherical mirror furnace (DSMF). The micrometric crystals were observed and chemically analysed with scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDX). The structural characterization and chemical analysis of these crystals were also carried out using transmission electron microscopy (TEM) and high-resolution transmission electron microscopy (HRTEM), together with electron-energy-loss spectroscopy (EELS). We found that the new quaternary compound crystallizes in the orthorhombic system with the point group mmm (D2h), space group Immm (No. 71) and cell parameters a=8.30 (10), b=8.18 (10), c=8.22 (10) A and V=558.76 A3.


Asunto(s)
Germanio/química , Manganeso/química , Microscopía Electrónica/métodos , Oxígeno/química , Samario/química , Cristalografía/métodos , Modelos Moleculares , Estructura Molecular
5.
Rev. Fac. Cienc. Méd. (Córdoba) ; Rev. Fac. Cienc. Méd. (Córdoba);26(3): 331-5, 1968 Jul-Dec.
Artículo en Español | LILACS-Express | BINACIS | ID: biblio-1170770
6.
Rev. Fac. Cienc. Méd. (Córdoba) ; 26(3): 331-5, 1968 Jul-Dec.
Artículo en Español | BINACIS | ID: bin-41261
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA