RESUMEN
The dimensional accuracy, surface hardness and reproduction of surface detail of stone casts produced from alginate impressions treated with 4.65% sodium hypochlorite, were investigated. To test dimensional accuracy, a Reflex Microscope was used to compare casts from 10 untreated impressions with casts from 10 impressions immersed in the solution for 30 mins. Surface detail and hardness were investigated on casts produced from impressions of a master stainless steel plate with 10 micro-indentations of increasing size. Surface detail of the casts were assessed by observation and surface hardness by a Vickers Hardness Machine. The dimensional accuracy test showed no significant differences between the experimental and control groups. Surface detail was unaffected after immersion of up to 10 mins. Surface hardness decreased linearly with respect to immersion time, when this was greater than 5 mins.
Asunto(s)
Alginatos , Sulfato de Calcio/química , Desinfectantes Dentales/química , Materiales de Impresión Dental , Modelos Dentales , Dureza , Ensayo de Materiales , Reproducibilidad de los Resultados , Hipoclorito de Sodio/química , Propiedades de SuperficieRESUMEN
This article describes the process of making and using a surgical guide stent. It is intended to enable the surgeon to maintain the same horizontal and vertical axes of cylindrical endosseous implants during the surgical phase of implant placement as those determined at the treatment planning stage. Furthermore, the stent can be used with the entire series of surgical drills, thereby minimizing the chance of inadvertently enlarging the implant site as a result of freehand use of the handpiece.