1.
J Hand Surg Am ; 48(12): 1274.e1-1274.e6, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-35718584

RESUMEN

PURPOSE: There appears to be controversy regarding differing patient and physician perceptions of adverse effects (AEs) in the treatment of Dupuytren disease with collagenase clostridium histolyticum (CCH). The aim of this study was to compare the number, type, and severity of AEs perceived and reported by patients and by their physician METHODS: To assess AEs following CCH injection in a standardized way, patients were given a list of predefined complications and asked to rate their severity on a 4-point Likert scale ranging from 1 (serious) to 4 (insignificant). RESULTS: Eighty-five patients were included. Patients reported fewer AEs than their physician (mean, 1.48 vs 2.18). There was no agreement between physician- and patient-reported AEs except for skin lacerations, which showed fair agreement (κ = 0.257). CONCLUSIONS: Patients and physicians differ in their evaluation of AEs due to CCH treatment in Dupuytren disease. A fair level of agreement was observed for skin lacerations. CLINICAL RELEVANCE: Greater consensus is needed when defining AEs associated with CCH in the treatment of Dupuytren disease.


Asunto(s)
Contractura de Dupuytren , Laceraciones , Humanos , Contractura de Dupuytren/tratamiento farmacológico , Estudios Prospectivos , Resultado del Tratamiento , Laceraciones/etiología , Inyecciones Intralesiones , Clostridium histolyticum , Colagenasa Microbiana/efectos adversos
2.
Eur J Orthop Surg Traumatol ; 28(3): 463-469, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29082427

RESUMEN

PURPOSE: The objective was to assess aseptic complications and functional outcome using a primary total hip arthroplasty with modular neck. METHODS: Prospective cohort of 317 consecutive patients. The mean age was 61.1 (range, 41-84) years. The H-Max-M model (Lima, Italy) system was used in all patients. The functional assessment was made by the Harris Hip Score, Short Form-36 (SF-36), Western Ontario and McMaster Universities Osteoarthritis Index and visual analogue scale for pain. Radiological outcomes were also assessed, and adverse events and complications were noted. RESULTS: The mean follow-up was 6.1 (range, 2-8) years. Functional outcome significantly improved in most patients. There were 3 deep infections (0.9%) and 17 aseptic complications (5.3%) including 1 intraoperative acetabular fracture, 3 later periprosthetic femoral fractures, 1 broken ceramic insert, 1 acetabular loosening, 3 femoral loosening and 1 broken titanium modular neck in a obese patient. No pseudotumors or elevated serum levels of metal ions were found among the patients with radiolucent lines or aseptic loosening. CONCLUSIONS: The findings in the present study showed that the H-MAX-M stem provided satisfactory functional outcome in most patients with a low rate of complications attributable to the modular neck design. We consider that using this novel modular neck-stem coupling design can be an alternative to the conventional monoblock stems in patients without overweight.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Diseño de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Seguridad del Paciente , Fracturas Periprotésicas/etiología , Estudios Prospectivos , Falla de Prótesis/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Resultado del Tratamiento