1.
Artif Organs ; 23(9): 876-80, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10491037

RESUMEN

Leading international institutions are designing and developing various types of ventricular assist devices (VAD) and total artificial hearts (TAH). Some of the commercially available pulsatile VADs are not readily implantable into the thoracic cavity of smaller size patients because of size limitation. The majority of the TAH dimensions requires the removal of the patients' native heart. A miniaturized artificial heart, the auxiliary total artificial heart (ATAH), is being developed in these authors' laboratories. This device is an electromechanically driven ATAH using a brushless direct current (DC) motor fixed in a center metallic piece. This pusher plate-type ATAH control is based on Frank-Starling's law. The beating frequency is regulated through the change of the left preload, assisting the native heart in obtaining adequate blood flow. With the miniaturization of this pump, the average sized patient can have the surgical implantation procedure in the right thoracic cavity without removing the native heart. The left and right stroke volumes are 35 and 32 ml, respectively. In vitro tests were conducted, and the performance curves demonstrate that the ATAH produces 5 L/min of cardiac output at 180 bpm (10 mmHg of left inlet mean pressure and 100 mm Hg of left outlet mean pressure). Taking into account that this ATAH is working along with the native heart, this output is more than satisfactory for such a device.


Asunto(s)
Corazón Artificial , Presión Sanguínea , Gasto Cardíaco , Suministros de Energía Eléctrica , Electricidad , Corazón/fisiología , Frecuencia Cardíaca , Corazón Auxiliar , Humanos , Ensayo de Materiales , Miniaturización , Diseño de Prótesis , Volumen Sistólico , Función Ventricular Izquierda
2.
Artif Organs ; 21(7): 680-5, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9212938

RESUMEN

The spiral pump (SP) uses centrifugal and axial pumping principles simultaneously, through a conical shaped impeller with threads in its surface. Flow visualization studies were performed in critical areas of the SP. A closed circuit loop was filled with glycerin-water solution (40%). Amberlite particles (80 mesh) were illuminated by a planar helium-neon laser light (7 mW). The particle velocities were recorded with Kodak (TMAX-400) black and white film, and the flow behavior was studied with a micro video camera and color video printer. The flow visualization studies showed no turbulence or stagnant areas in the inlet and outlet ports of the SP. When using the impeller with one lead, at the top of the threads some recirculation appeared when the total pressure head increased. Two new impellers were made. One of them had the same conical shape with a thread having 2 leads. The second had a thread with 2 leads, but it also had a bigger cone angle. These modifications improved the pump hydrodynamic performance, decreasing the recirculation in pumping conditions that require pressures over 200 mm Hg.


Asunto(s)
Corazón Auxiliar/normas , Centrifugación , Glicerol/química , Helio , Flujometría por Láser-Doppler , Neón , Tamaño de la Partícula , Control de Calidad , Resinas Sintéticas/metabolismo , Grabación en Video , Agua/química
3.
Artif Organs ; 20(6): 605-12, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8817964

RESUMEN

Two well-known centrifugal and axial pumping principles are used simultaneously in a new blood pump design. Inside the pump housing is a spiral impeller, a conically shaped structure with threads on the surface. The worm gears provide an axial motion of the blood column through the threads of the central cone. The rotational motion of the conical shape generates the centrifugal pumping effect and improves the efficiency of the pump without increasing hemolysis. The hydrodynamic performance of the pump was examined with a 40% glycerin-water solution at several rotation speeds. The gap between the housing and the top of the thread is a very important factor: when the gap increases, the hydrodynamic performance decreases. To determine the optimum gap, several in vitro hemolysis tests were performed with different gaps using bovine blood in a closed circuit loop under two conditions. The first simulated condition was a left ventricular assist device (LVAD) with a flow rate of 5 L/min against a pressure head of 100 mm Hg, and the second was a cardiopulmonary bypass (CPB) simulation with a flow rate of 5 L/min against 350 mm Hg of pressure. The best hemolysis results were seen at a gap of 1.5 mm with the normalized index of hemolysis (NIH) of 0.0063 +/- 0.0020 g/100 L and 0.0251 +/- 0.0124 g/100 L (mean +/- SD; n = 4) for LVAD and CPB conditions, respectively.


Asunto(s)
Corazón Auxiliar/normas , Animales , Bovinos , Diseño de Equipo/tendencias , Glicerol , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/tendencias , Hemoglobinas/análisis , Hemólisis , Técnicas In Vitro , Reología , Trombosis/prevención & control , Agua