Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 24(7): 955.e1-4, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20832000

RESUMEN

Abdominal aortic dissection (AAD) is a rare pathology and potentially causes rupture or other serious complications. This case report details our experience in endovascular aneurysm repair for AAD in a patient who had a history of coronary bypass surgery. Circumferential dissection of terminal aorta showed stenosis of true lumen as well as blood flow present in the pseudolumen. Using Zenith AAA endovascular device, the entry site was closed and the pseudolumen was thrombosed successfully. In the present report, published data on AAD were reviewed and endovascular aneurysm repair as a treatment option has been discussed as well.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Puente de Arteria Coronaria , Procedimientos Endovasculares/instrumentación , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Stents , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
2.
Gen Thorac Cardiovasc Surg ; 57(4): 203-7, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19367453

RESUMEN

This case report details our experience with endovascular stent-graft repair for an abdominal aortic aneurysm (AAA) in a patient who was previously treated by left ventricular remodeling for dilated cardiomyopathy. Renal dysfunction with an elevated creatinine level (1.59 mg/dl) was managed by reducing the dose of contrast medium utilizing intravascular ultrasonography. Using a Zenith AAA endovascular device, the aneurysmal sac was successfully excluded and was thrombosed. Endovascular stenting is a good treatment option for abdominal aneurysm repair in patients with poor heart function and renal impairment.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Stents , Aneurisma de la Aorta Abdominal/diagnóstico , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/cirugía , Medios de Contraste/administración & dosificación , Diagnóstico por Imagen , Humanos , Fallo Renal Crónico/complicaciones , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA