RESUMEN
BACKGROUND AND AIM: Dialysis patients are a high-risk population and have a reduced immune response to vaccination against SARS-CoV-2. The aim of this study was to assess the humoral response to homologous Gam-COVID-Vac (Sputnik V) and heterologous Sputnik V/mRNA-1273 (Moderna) vaccination in dialysis patients. The vaccination scheme depended on dose availability and the prioritization of risk populations as established by the Argentine Ministry of Health. METHODS: Previous COVID-19 infection was determined in symptomatic patients. Binding IgG antibodies against the spike (S) receptor-binding domain (RBD) of SARS-CoV-2 (anti-S-RBD) concentration was assessed between 3 and 16 weeks after the boost dose. Anti-S-RBD antibodies were quantified using the Abbott Diagnostics SARS-CoV-2 IgG II Quant chemiluminescent microparticle immunoassay (CMIA) on an Architect i2000 SR and an Alinity I analyzer (Abbott Diagnostics, Abbott Park, Illinois, USA). To standardize the results to WHO binding antibody units (BAU), a correction factor for Abbott arbitrary units (AU) was applied where 1 BAU/mL equals 0.142 AU, as previously established by Abbott with the WHO international standard NIBSC 20-136. Following the manufacturer's recommendations, samples were considered reactive for anti-S-RBD when titers were above 50 AU/mL (7.2 BAU/mL). An 80% protective effect (PROT-80) against symptomatic SARS-CoV-2 infection was assumed when anti-S-RBD titers were 506 BAU/ml or higher. Charlson Comorbidity Index (CCI) score was classified as mild = 1-2, moderate = 3-4, and severe ≥ 5. Side effects were evaluated until day 7 by patients´ self-reported questionnaire. RESULTS: One hundred seven participants were enrolled [n = 84 homologous (SpV/SpV), nn 23 heterologous (SpV/Mod)]. Median (IQR) age was 64 (50-75) years old and 79 (73.8%) were male. Additionally, 19 (22.6%) of the SpV/SpV and 4 (17.4%) of the SpV/Mod group had a prior confirmed SARS-CoV-2 infection (p = 0.589). In the overall population, 103 patients reached seroconversion (96.3%). Anti-S-RBD IgG median titers (IQR) were higher in the heterologous [1222 (288-5680) BAU/mL] than in the homologous scheme [447 (100-1551) BAU/mL], p = 0.022. In a linear model adjusted for age, gender, days from first vaccination to boost dose and days from the boost dose to the anti-S-RBD IgG determination, previous SARS-COV-2 infection (B: 2062.2; CI95: 1231.8-2892.6; p < 0.001), and SpV/Mod vaccination scheme (B: 1294.6; CI95: 435.58-2147.6; p = 0.003) were independently associated with anti-S-RBD levels. Finally, a higher frequency of adverse effects was associated with the heterologous scheme, although they were well tolerated by all individuals. CONCLUSIONS: The present study provides evidence that the homologous SpV/SpV and heterologous SpV/Mod schemes showed good efficacy and safety in patients on chronic dialysis. These results could be useful for designing future vaccination strategies, especially aimed at this risk group.
Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Vacuna nCoV-2019 mRNA-1273 , Diálisis Renal , Inmunoglobulina GAsunto(s)
Vacuna nCoV-2019 mRNA-1273 , COVID-19 , Humanos , COVID-19/prevención & control , VacunaciónRESUMEN
OBJECTIVES: To compare the homologous prime-boost vaccination scheme of Gam-COVID-Vac (Sputnik V (SpV)) to its heterologous combination with mRNA-1273 (Moderna (Mod)) vaccine. METHODS: SARS-CoV-2 anti-spike (S)-receptor binding domain (RBD) IgG concentration was assessed three to seven weeks after complete vaccination. Reactogenicity was evaluated by declared side events and medical assistance required until day 7 post boost. RESULTS: Of 190 participants enrolled, 105 received homologous SpV/SpV and the remaining heterologous SpV/Mod vaccination scheme, respectively. Median (interquartile range (IQR)) age was 54 (37-63) years, 132 out of 190 (69.5%) were female, and 46 out of 190 (24.2%) individuals had a prior confirmed COVID-19. Anti-S-RBD IgG median (IQR) titers were significantly higher for SpV/Mod (2511 (1476-3992) binding antibody units (BAU)/mL) than for SpV/SpV (582 (209-1609) BAU/mL; p < 0.001] vaccination scheme. In a linear model adjusted for age, gender, time to the serological assay, and time between doses, SpV/Mod (4.154 (6.585-615.554); p < 0.001] and prior COVID (3.732 (8.641-202.010); p < 0.001) were independently associated with higher anti-S-RBD IgG values. A higher frequency of mild and moderate adverse effects was associated with the heterologous scheme (20 of 85 (23.5%) vs. 13 of 105 (12.4%); p = 0.043 and 27 of 85 (31.8%) vs. 14 of 105 (13.3%); p = 0.002), respectively, although it was well tolerated by all individuals and no medical assistance was required. DISCUSSION: The heterologous SpV/Mod combination against SARS-CoV-2 is well tolerated and significantly increases humoral immune response as compared to the homologous SpV/SpV immunization.
Asunto(s)
Vacuna nCoV-2019 mRNA-1273 , COVID-19 , Vacuna nCoV-2019 mRNA-1273/efectos adversos , Anticuerpos Antivirales , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Análisis de Datos , Femenino , Humanos , Inmunoglobulina G , Masculino , Persona de Mediana Edad , SARS-CoV-2/genéticaRESUMEN
Direct acting antiviral (DAA) therapy against hepatitis C virus (HCV) increases sustained virologic response rates. Nevertheless, drug resistance has occasionally been associated with failure to DAA. However, the information about the prevalence of NS5A and NS5B resistance-associated substitutions (RASs) in Argentina is very scarce. In this study, we determine the prevalence of NS5A and NS5B resistances to treatment in Argentinean DAA treatment-naïve patients chronically infected with genotype 1 (HCV-1). In this retrospective cross-sectional study, 108 HCV-1-infected patients were studied. RASs in NS5A and NS5B were analyzed by Sanger at baseline and phylogenetic analysis was performed. NS5A and NS5B RASs were detected in 25.8% and 6.3% of the analyzed sequences, respectively. The most frequent primary RASs for NS5A were L31M (7.5%) and Y93H (3.2%) and for NS5B was L159F (3.8%). No association between the presence of RASs and the outcome of DAA treatment was found in this study. Additionally, most of the Argentinean samples were randomly distributed among sequences around the world in the phylogenetic analysis. Only one significant Argentinean cluster was observed in both regions but without any particular RASs pattern. Baseline RASs in NS5A and NS5B were frequently observed in HCV-1-infected patients from Buenos Aires, Argentina but not related to treatment outcome. No clusters related to RASs transmission were observed in the phylogenetic analysis. The frequency of RASs detected in this study supports the need for more molecular epidemiology studies on RASs to adjust local treatment guidelines with the incorporation of autochthonous data.
Asunto(s)
Sustitución de Aminoácidos , Antivirales/uso terapéutico , Farmacorresistencia Viral/genética , Hepacivirus/genética , Proteínas no Estructurales Virales/genética , Adulto , Anciano , Anciano de 80 o más Años , Argentina/epidemiología , Estudios Transversales , Femenino , Genotipo , Hepatitis C Crónica/tratamiento farmacológico , Hepatitis C Crónica/epidemiología , Hepatitis C Crónica/virología , Humanos , Masculino , Persona de Mediana Edad , Filogenia , Prevalencia , Estudios RetrospectivosRESUMEN
OBJECTIVE: To evaluate the use of hepatitis C virus (HCV) NS3 sequencing as alternative to the comercially available Versant HCV 2.0 reverse hybridization line-probe assay (LiPA 2.0) to determine HCV genotype 1 (HCV-1) subtypes. PATIENTS AND METHODS: A cohort of 104 patients infected by HCV-1 according to LiPA 2.0 was analyzed in a cross-sectional study conducted in patients seen from January 2012 to June 2016 at an outpatient clinic in Buenos Aires, Argentina. RESULTS: The samples were included within well supported subtype clades: 64 with HCV-1b and 39 with HCV-1a infection. Twenty of the HCV-1a infected patientes were included in a supported sub-clade "1" and 19 individuals were among the basal sub-clade "2". LiPA 2.0 failed to subtype HCV-1 in 20 (19.2%) individuals. Subtype classification determined by NS3 direct sequencing showed that 2/18 (11.1%) of the HCV-1a-infected patients as determined by LiPA 2.0 were in fact infected by HCV-1b. Of the HCV-1b-infected according to LiPA 2.0, 10/66 (15.2%) patients showed HCV-1a infection according to NS3 sequencing. Overall misclassification was 14.3% (κ-index for the concordance with NS3 sequencing = 0.635). One (1%) patient was erroneously genotyped as HCV-1 and was revealed as HCV genotype 4 infection. CONCLUSIONS: Genomic sequencing of the HCV NS3 region represents an adequate alternative since it provides reliable genetic information. It even distinguishes between HCV-1a clades related to resistance-associated substitutions to HCV protease inhibitors, it provides reliable genetic information for genotyping/subgenotyping and simultaneously allows to determine the presence of resistance-associated substitutions to currently recommended DAAs.