Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Sci Robot ; 9(87): eadh0298, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38354258

RESUMEN

Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician's skill and the device's ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device's surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.


Asunto(s)
Robótica , Humanos , Animales , Porcinos , Movimiento (Física) , Fenómenos Magnéticos
2.
Nat Commun ; 11(1): 5957, 2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33235190

RESUMEN

Metals and polymers are dissimilar materials in terms of their physicochemical properties, but complementary in terms of functionality. As a result, metal-organic structures can introduce a wealth of novel applications in small-scale robotics. However, current fabrication techniques are unable to process three-dimensional metallic and polymeric components. Here, we show that hybrid microstructures can be interlocked by combining 3D lithography, mold casting, and electrodeposition. Our method can be used to achieve complex multi-material microdevices with unprecedented resolution and topological complexity. We show that metallic components can be combined with structures made of different classes of polymers. Properties of both metals and polymers can be exploited in parallel, resulting in structures with high magnetic responsiveness, elevated drug loading capacity, on-demand shape transformation, and elastic behavior. We showcase the advantages of our approach by demonstrating new microrobotic locomotion modes and controlled agglomeration of swarms.

3.
Osteoarthritis Cartilage ; 28(9): 1235-1244, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32278071

RESUMEN

OBJECTIVE: Evaluate articular cartilage by magnetic resonance imaging (MRI) T2∗ mapping within the distal femur and proximal tibia in adolescents with juvenile osteochondritis dissecans (JOCD). DESIGN: JOCD imaging studies acquired between August 2011 and February 2019 with clinical and T2∗ mapping MRI knee images were retrospectively collected and analyzed for 31 participants (9F/22M, 15.0 ± 3.8 years old) with JOCD lesions in the medial femoral condyle (MFC). In total, N = 32 knees with JOCD lesions and N = 14 control knees were assessed. Mean T2∗ values in four articular cartilage regions-of-interest (MFC, lateral femoral condyle (LFC), medial tibia (MT), and lateral tibia (LT)) and lesion volume were measured and analyzed using Wilcoxon-rank-sum tests and Spearman correlation coefficients (R). RESULTS: Mean ± standard error T2∗ differences observed between the lesion-sided MFC and the LFC in JOCD-affected knees (28.5 ± 0.9 95% confidence interval [26.8, 30.3] vs 26.3 ± 0.7 [24.8, 27.7] ms, P = 0.088) and between the affected- and control-knee MFC (28.5 ± 0.9 [26.8, 30.3] vs 28.5 ± 0.6 [27.1, 29.9] ms, P = 0.719) were nonsignificant. T2∗ was significantly increased in the lesion-sided MT vs the LT for the JOCD-affected knees (21.5 ± 0.7 [20.1, 22.9] vs 18.0 ± 0.7 [16.5, 19.5] ms, P = 0.002), but this same difference was also observed between the MT and LT in control knees (21.0 ± 0.6 [19.7, 22.3] vs 18.1 ± 1.1 [15.8, 20.4] ms, P = 0.037). There was no significant T2∗ difference between the affected- and control-knee MT (21.5 ± 0.7 [20.1, 22.9] vs 21.0 ± 0.6 [19.7, 22.3] ms, P = 0.905). T2∗ within the lesion-sided MFC was not correlated with patient age (R = 0.20, P = 0.28) or lesion volume (R = 0.06, P = 0.75). T2∗ values were slightly increased near lesions in later-stage JOCD subjects but without statistical significance. CONCLUSIONS: T2∗ relaxations times were not significantly different from control sites in the articular cartilage overlying JOCD lesions in the MFC or adjacent MT cartilage in early-stage JOCD.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Osteocondritis Disecante/diagnóstico por imagen , Adolescente , Edad de Inicio , Niño , Femenino , Fémur/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Adulto Joven
4.
Anaesthesia ; 75(7): 881-886, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31900928

RESUMEN

Robotic endoscope-automated via laryngeal imaging for tracheal intubation (REALITI) has been developed to enable automated tracheal intubation. This proof-of-concept study using a convenience sample of participants, comprised of trained anaesthetists and lay participants with no medical training, assessed the performance of a robotic device for the insertion of a tracheal tube into a manikin. A prototype robotic endoscope device was inserted into the trachea of an airway manikin by seven anaesthetists and seven participants with no medical training. Each individual performed six device insertions into the trachea in manual mode and six in automated mode. The anaesthetists succeeded with 40/42 (95%) manual insertions (median (IQR [range]) 17 (12-26 [4-132]) s) and 40/42 (95%) automated insertions (15 (13-18 [7-25]) s). The non-trained participants succeeded in 41/42 (98%) manual insertions (median (IQR [range]) 18 (13-21 [8-133]) s) and 42/42 (100%) automated insertions (16 (13-23 [10-58])] s). The duration of insertion did not differ between groups. An effect of increasing experience was observed in both groups in manual mode. A Likert scale for 'ease of use' (0 = very difficult to 10 = very easy) showed similar results within the two groups; the mean (SD) was 5.9 (2.1) for the anaesthetists and 6.9 (1.3) for the non-trained participants. We have successfully performed the first automated tracheal device insertion in a manikin with comparable results in a convenience sample of anaesthetists and lay participants with no medical training.


Asunto(s)
Intubación Intratraqueal/instrumentación , Laringoscopios , Robótica/instrumentación , Adulto , Competencia Clínica , Femenino , Humanos , Intubación Intratraqueal/métodos , Masculino , Maniquíes , Prueba de Estudio Conceptual , Robótica/métodos , Factores de Tiempo , Interfaz Usuario-Computador , Grabación en Video/métodos , Adulto Joven
5.
Sci Adv ; 5(4): eaav4803, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-31032412

RESUMEN

Nanoparticles (NPs) have emerged as an advantageous drug delivery platform for the treatment of various ailments including cancer and cardiovascular and inflammatory diseases. However, their efficacy in shuttling materials to diseased tissue is hampered by a number of physiological barriers. One hurdle is transport out of the blood vessels, compounded by difficulties in subsequent penetration into the target tissue. Here, we report the use of two distinct micropropellers powered by rotating magnetic fields to increase diffusion-limited NP transport by enhancing local fluid convection. In the first approach, we used a single synthetic magnetic microrobot called an artificial bacterial flagellum (ABF), and in the second approach, we used swarms of magnetotactic bacteria (MTB) to create a directable "living ferrofluid" by exploiting ferrohydrodynamics. Both approaches enhance NP transport in a microfluidic model of blood extravasation and tissue penetration that consists of microchannels bordered by a collagen matrix.


Asunto(s)
Nanopartículas/química , Bacterias/metabolismo , Transporte Biológico , Convección , Portadores de Fármacos/química , Portadores de Fármacos/metabolismo , Sistemas de Liberación de Medicamentos , Flagelos/metabolismo , Humanos , Nanopartículas/metabolismo
6.
Sci Adv ; 5(1): eaau1532, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30746446

RESUMEN

Bacteria can exploit mechanics to display remarkable plasticity in response to locally changing physical and chemical conditions. Compliant structures play a notable role in their taxis behavior, specifically for navigation inside complex and structured environments. Bioinspired mechanisms with rationally designed architectures capable of large, nonlinear deformation present opportunities for introducing autonomy into engineered small-scale devices. This work analyzes the effect of hydrodynamic forces and rheology of local surroundings on swimming at low Reynolds number, identifies the challenges and benefits of using elastohydrodynamic coupling in locomotion, and further develops a suite of machinery for building untethered microrobots with self-regulated mobility. We demonstrate that coupling the structural and magnetic properties of artificial microswimmers with the dynamic properties of the fluid leads to adaptive locomotion in the absence of on-board sensors.

7.
Nanoscale ; 8(25): 12723-8, 2016 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-27297037

RESUMEN

Wirelessly guided magnetic nanomachines are promising vectors for targeted drug delivery, which have the potential to minimize the interaction between anticancer agents and healthy tissues. In this work, we propose a smart multifunctional drug delivery nanomachine for targeted drug delivery that incorporates a stimuli-responsive building block. The nanomachine consists of a magnetic nickel (Ni) nanotube that contains a pH-responsive chitosan hydrogel in its inner cavity. The chitosan inside the nanotube serves as a matrix that can selectively release drugs in acidic environments, such as the extracellular space of most tumors. Approximately a 2.5 times higher drug release from Ni nanotubes at pH = 6 is achieved compared to that at pH = 7.4. The outside of the Ni tube is coated with gold. A fluorescein isothiocyanate (FITC) labeled thiol-ssDNA, a biological marker, was conjugated on its surface by thiol-gold click chemistry, which enables traceability. The Ni nanotube allows the propulsion of the device by means of external magnetic fields. As the proposed nanoarchitecture integrates different functional building blocks, our drug delivery nanoplatform can be employed for carrying molecular drug conjugates and for performing targeted combinatorial therapies, which can provide an alternative and supplementary solution to current drug delivery technologies.


Asunto(s)
Antineoplásicos/administración & dosificación , Sistemas de Liberación de Medicamentos , Nanopartículas del Metal , Línea Celular Tumoral , Quitosano , Liberación de Fármacos , Fluoresceína , Oro , Humanos , Hidrogeles , Concentración de Iones de Hidrógeno , Isotiocianatos , Neoplasias/tratamiento farmacológico , Níquel
8.
Nanoscale ; 8(3): 1344-51, 2016 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-26399166

RESUMEN

The effects of constrained sample dimensions on the mechanical behavior of crystalline materials have been extensively investigated. However, there is no clear understanding of these effects in nano-sized amorphous samples. Herein, nanoindentation together with finite element simulations are used to compare the properties of crystalline and glassy CoNi(Re)P electrodeposited nanowires (ϕ ≈ 100 nm) with films (3 µm thick) of analogous composition and structure. The results reveal that amorphous nanowires exhibit a larger hardness, lower Young's modulus and higher plasticity index than glassy films. Conversely, the very large hardness and higher Young's modulus of crystalline nanowires are accompanied by a decrease in plasticity with respect to the homologous crystalline films. Remarkably, proper interpretation of the mechanical properties of the nanowires requires taking the curved geometry of the indented surface and sink-in effects into account. These findings are of high relevance for optimizing the performance of new, mechanically-robust, nanoscale materials for increasingly complex miniaturized devices.

9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 7970-3, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26738141

RESUMEN

This paper presents a magnetically guided catheter for minimally invasive surgery (MIS) with a magnetic force sensing tip. The force sensing element utilizes a magnetic Hall sensor and a miniature permanent magnet mounted on a flexible encapsulation acting as the sensing membrane. It is capable of high sensitivity and robust force measurements suitable for in-vivo applications. A second larger magnet placed on the catheter allows the catheter to be guided by applying magnetic fields. Precise orientation control can be achieved with an external magnetic manipulation system. The proposed device can be used in many applications of minimally invasive surgery (MIS) to detect forces applied on tissue during procedures or to characterize different types of tissue for diagnosis.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos , Catéteres , Magnetismo , Fenómenos Mecánicos
10.
Bioinspir Biomim ; 9(4): 046014, 2014 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-25405833

RESUMEN

Artificial bacterial flagella (ABFs) are magnetically actuated swimming microrobots inspired by Escherichia coli bacteria, which use a helical tail for propulsion. The ABFs presented are fabricated from a magnetic polymer composite (MPC) containing iron-oxide nanoparticles embedded in an SU-8 polymer that is shaped into a helix by direct laser writing. The paper discusses the swim performance of MPC ABFs fabricated with varying helicity angles. The locomotion model presented contains the fluidic drag of the microrobot, which is calculated based on the resistive force theory. The robot's magnetization is approximated by an analytical model for a soft-magnetic ellipsoid. The helicity angle influences the fluidic and magnetic properties of the robot, and it is shown that weakly magnetized robots prefer a small helicity angle to achieve corkscrew-type motion.


Asunto(s)
Biomimética/instrumentación , Flagelos/fisiología , Nanopartículas de Magnetita/química , Sistemas Microelectromecánicos/instrumentación , Polímeros/química , Robótica/instrumentación , Natación/fisiología , Fenómenos Fisiológicos Bacterianos , Simulación por Computador , Diseño Asistido por Computadora , Módulo de Elasticidad/fisiología , Diseño de Equipo , Análisis de Falla de Equipo , Imanes , Miniaturización , Modelos Biológicos , Navíos/instrumentación
11.
Nanoscale ; 6(9): 4683-90, 2014 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-24651381

RESUMEN

Researchers have been investigating various methodologies for fabricating well-defined, homogenous composites consisting of nanoparticles (NPs) dispersed in a matrix. The main challenges are to prevent particle agglomerations during fabrication and to obtain nanoparticles whose size distribution could be tuned on demand. One of the methods that can provide these features is electrodeposition. We report for the first time the fabrication of a thin magnetic multilayer nanocomposite film by electrodeposition from one bath containing both a monomer and metal salts. Cobalt and cobalt-nickel NPs were deposited on conductive polymer polypyrrole thin films using different electrodeposition potentials and times. Multilayer nanocomposite films were fabricated by subsequent electrodeposition of polymer and nanoparticle layers. Scanning electron microscopy analysis showed that a wide range of NPs (70-230 nm) could be synthesized by manipulating growth potentials and times. The cobalt-nickel NPs were found to contain hexagonal close-packed (hcp) and face-centered cubic (fcc) phases based on X-ray diffraction and selected area electron diffraction. Magnetic measurements proved that both the single and the multi-layered nanocomposites were magnetic at room temperature.

12.
Nanoscale ; 4(10): 3083-8, 2012 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-22422198

RESUMEN

Porous nanostructures of polypyrrole (Ppy) were fabricated using colloidal lithography and electrochemical techniques for potential applications in drug delivery. A sequential fabrication method was developed and optimized to maximize the coverage of the Ppy nanostructures and to obtain a homogeneous layer over the substrate. This was realized by masking with electrophoretically-assembled polystyrene (PS) nanospheres and then electroplating. Drug/biomolecule adsorption and the release characteristics for the porous nanostructures of Ppy were investigated using rhodamine B (Rh-B). Rh-B is an easily detectable small hydrophobic molecule that is used as a model for many drugs or biological substances. The porous Ppy nanostructures with an enhanced surface area exhibited higher Rh-B loading capacity than bulk planar films of Ppy. Moreover, tunability of surface morphology for further applications (e.g., sensing, cell adhesion) was demonstrated.


Asunto(s)
Coloides/química , Portadores de Fármacos/química , Nanoestructuras/química , Polímeros/química , Pirroles/química , Adsorción , Poliestirenos/química , Porosidad , Rodaminas/química
13.
Nanotechnology ; 23(6): 065604, 2012 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-22248487

RESUMEN

We demonstrate a one-step approach for selecting the number of walls formed during carbon nanotube (CNT) growth by catalytic decomposition of CH(4) over Fe-Mo/MgO catalysts. Scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HRTEM), thermal gravimetric analysis (TGA) and Raman spectroscopy analyses indicate that high purity single-walled, double-walled and triple-walled carbon nanotubes can be synthesized by tuning the Fe:Mo atomic ratio of catalysts. The results reveal that the concentration of Mo in the catalyst plays an important role in the size of catalyst particles and in the deposition rate of carbon atoms during CNT growth. Thus, the wall numbers of CNTs can be controlled precisely.

14.
Ultrasonics ; 52(3): 447-55, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22112792

RESUMEN

Passive localization of an object from its emission can be based on time difference of arrival or phase shift measurements for different receiver groups in sensor arrays. The accuracy of the localization primarily depends on accurate time and/or phase measurements. The frequency of the emission and the number and arrangement of the receivers mainly effect the resolution of the emitter localization. In this paper optimal receiver positions for passive localization methods are proposed, resulting in a maximal resolution for the emitter location estimate. The optimization is done by analyzing the uncertainty of the emitted signal, including its frequency. The technique has been developed specifically for ultrasound signals obtained from omnidirectional transducers, although the results apply for other application using passive localization techniques.


Asunto(s)
Ultrasonido/métodos , Transductores
15.
Nanoscale ; 3(10): 4301-6, 2011 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-21901216

RESUMEN

Mechanical properties of self-scrolling binormal nanohelices with a rectangular cross-section are investigated under uniaxial tensile and compressive loads using nanorobotic manipulation and Cosserat curve theory. Stretching experiments demonstrate that small-pitch nanohelices have an exceptionally large linear elasticity region and excellent mechanical stability, which are attributed to their structural flexibility based on an analytical model. In comparison between helices with a circular, square and rectangular cross-section, modeling results indicate that, while the binormal helical structure is stretched with a large strain, the stress on the material remains low. This is of particular significance for such applications as elastic components in micro-/nanoelectromechanical systems (MEMS/NEMS). The mechanical instability of a self-scrolling nanohelix under compressive load is also investigated, and the low critical load for buckling suggests that the self-scrolling nanohelices are more suitable for extension springs in MEMS/NEMS.


Asunto(s)
Nanoestructuras/química , Cromo/química , Elasticidad , Germanio/química , Nanotecnología , Silicio/química , Resistencia a la Tracción
16.
Nanotechnology ; 22(27): 275713, 2011 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-21606563

RESUMEN

We report on the growth and fabrication of Ni-filled multi-walled carbon nanotubes (Ni-MWNTs) with an average diameter of 115 nm and variable length of 400 nm-1 µm. The Ni-MWNTs were grown using template-assisted electrodeposition and low pressure chemical vapor deposition (LPCVD) techniques. Anodized alumina oxide (AAO) templates were fabricated on Si using a current controlled process. This was followed by the electrodeposition of Ni nanowires (NWs) using galvanostatic pulsed current (PC) electrodeposition. Ni NWs served as the catalyst to grow Ni-MWNTs in an atmosphere of H2/C2H2 at a temperature of 700 °C. Time dependent depositions were carried out to understand the diffusion and growth mechanism of Ni-MWNTs. Characterization was carried out using scanning electron microscopy (SEM), focused ion beam (FIB) milling, transmission electron microscopy (TEM), Raman spectroscopy and energy dispersive x-ray spectroscopy (EDX). TEM analysis revealed that the Ni nanowires possess a fcc structure. To understand the effects of the electrodeposition parameters, and also the effects of the high temperatures encountered during MWNT growth on the magnetic properties of the Ni-MWNTs, vibrating sample magnetometer (VSM) measurements were performed. The template-based fabrication method is repeatable, efficient, enables batch fabrication and provides good control on the dimensions of the Ni-MWNTs.

17.
Artículo en Inglés | MEDLINE | ID: mdl-21097007

RESUMEN

We present a luminescence oxygen sensor incorporated in a wireless intraocular microrobot for minimally-invasive diagnosis. This microrobot can be accurately controlled in the intraocular cavity by applying magnetic fields. The microrobot consists of a magnetic body susceptible to magnetic fields and a sensor coating. This coating embodies Pt(II) octaethylporphine (PtOEP) dyes as the luminescence material and polystyrene as a supporting matrix, and it can be wirelessly excited and read out by optical means. The sensor works based on quenching of luminescence in the presence of oxygen. The excitation and emission spectrum, response time, and oxygen sensitivity of the sensor were characterized using a spectrometer. A custom device was designed and built to use this sensor for intraocular measurements with the microrobot. Due to the intrinsic nature of luminescence lifetimes, a frequency-domain lifetime measurement approach was employed. An alternative sensor implementation using poly(styrene-co-maleic anhydride) (PS-MA) and PtOEP was successfully demonstrated with nanospheres to increase sensor performance.


Asunto(s)
Oxígeno/química , Algoritmos , Humanos , Luminiscencia , Magnetismo , Anhídridos Maleicos/química , Microscopía Electrónica de Rastreo/métodos , Miniaturización , Nanosferas , Nanotecnología/métodos , Fenómenos Fisiológicos Oculares , Óptica y Fotónica , Poliestirenos/química , Robótica , Factores de Tiempo
18.
J Microsc ; 237(2): 122-35, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20096043

RESUMEN

A variety of different methods exist for gathering three-dimensional information for micro- and nanoscale objects. Tilting of samples in a scanning electron microscope provides a non-destructive way of generating these data. Traditionally, the reconstruction of this image data is performed by stereo photogrammetric methods that compare features from two or three frames. We propose the application of techniques from the structure-from-motion community as being efficient, high-precision alternatives to stereo methods, which allows for automated utilization of a large number of sampled images. We propose the use of nanobelts to generate localized rotational motions. Using this method alleviates the demand of high-precision actuators, allows 360 degrees rotations, and provides a useful tool for micro- and nanomanipulation.

19.
Ultrasonics ; 50(2): 247-57, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19837446

RESUMEN

Acoustic radiation forces have often been used for the manipulation of large amounts of micrometer sized suspended particles. The nature of acoustic standing wave fields is such that they are present throughout the whole fluidic volume; this means they are well suited to such operations, with all suspended particles reacting at the same time upon exposure. Here, this simultaneous positioning capability is exploited to pre-align particles along the centerline of channels, so that they can successively be removed by means of an external tool for further analysis. This permits a certain degree of automation in single particle manipulation processes to be achieved as initial identification of particles' location is no longer necessary, rather predetermined. Two research fields in which applications are found have been identified. First, the manipulation of copolymer beads and cells using a microgripper is presented. Then, sample preparation for crystallographic analysis by positioning crystals into a loop using acoustic manipulation and a laminar flow will be presented.

20.
Nanotechnology ; 20(49): 495704, 2009 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-19904022

RESUMEN

We report on the energetic and structural stability of configuration-tunable, bi-directional linear bearings based on cap-less, partial segments engineered within individual multi-walled carbon nanotubes (MWNTs). Using computational models, we show that an externally applied excitation force can be used to select an operating bearing configuration with a desired stiffness and operating frequency. Our models also demonstrate the possibility of simultaneous, independent operation of multiple bearings within a single NT segment, paving the way towards ultra-high device densities with molecular-scale footprints.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA