Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Exp Dent ; 16(8): e961-e966, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39281790

RESUMEN

Background: The use of enzymatic chemical agents are papain-based materials used in the selective removal of decayed dentin tissue, assisting in conservative techniques and reducing the chances of accidental pulp exposure. Material and Methods: A research protocol was subjected to and approved by an Ethics Committee. Using a reporting guide for laboratory studies (CRIS). Healthy human teeth comprised the produced dentin discs subjected to polishing and washing in an ultrasonic bath. Next, the discs received material application according to the experimental groups: water-soluble gel for two minutes, 37% phosphoric acid for 15 seconds in dentin and 30 seconds in enamel, Papacárie Duo (PD) for 30 seconds and two minutes, and Brix 3000 (BX) for two minutes and 30 seconds. The measurement of material pH used solutions at concentrations of 0.1 ml and 2.7 ml prepared for each enzymatic agent. Then, a bench pH meter (n=10) and pH indicator strips determined pH values. The discs underwent the Knoop hardness test (n=10). The sample calculation was performed using the GPower software with α = 0.05, effect 0.63 and power of 95%. Descriptive statistical analysis was carried out for pH, one way ANOVA supplemented by Tukey for knoop hardness and Spearman correlation for pH measurement techniques. Results: The enamel hardness findings indicated that, after material application, ECAs do not statistically differ from water-soluble gel (p<0.05). The dentinal hardness analysis presented a statistical difference in phosphoric acid from the other groups (p<0.05). In the pH test, BX values were lower (4.37 ± 0.01) than PD (4.85 ± 0.06). The groups statistically differed (p<0.05). Conclusions: ECAs for removing decayed dentin tissue did not significantly alter the hardness of enamel and dentin, removal of the smear layer is time-dependent and presents acidity. Key words:Dental caries, Hardness, Dental materials, Papain.

2.
J Mech Behav Biomed Mater ; 118: 104433, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33684707

RESUMEN

OBJECTIVE: To perform a systematic review of the literature focused to evaluate in vitro function of prefabricated fiber posts with and without customization by additional auxillary fiber posts and composite resin on the fracture strength of wide or enlarged canals and the failure pattern. METHODS: Six databases were used as primary search sources (PubMed, Scopus, LILACS, SciELO, Science Direct, and Web of Science) and three databases (Open Grey, Open Thesis, and OATD) were used to partially capture the "grey literature". The research included laboratory studies that used human upper anterior teeth aiming to assess the fracture strength and failure pattern of different glass fiber post customizations by additional auxiliary fiber posts or composite resin. The search had no restriction of year, language, and publication status. The risk of bias of the studies was assessed from the criteria established in systematic reviews of laboratory studies. Standardized mean differences were calculated by comparing the mean fracture strengths of customized and non-customized posts. Pooled estimates were calculated by Glass' delta method using the random-effects model. Subtotal estimates were presented according to each type of relining procedure and an overall estimate was described considering all studies combined. RESULTS: The search provided 2291 results, from which six met the eligibility criteria and were included in the qualitative assessment of the review. Only three studies presented a moderate risk of bias. The meta-analysis results showed that the use of auxiliary posts produced higher mean fracture strengths than non-customized posts (SMD = 2.21; 95%CI: 0.74; 3.68), and it was more effective than the use of composite resin to reline the posts. CONCLUSION: Based on laboratories studies, even though has not been observed any difference to a statistically significant level on fracture strength and failure pattern of the customized and non-customized post, future studies should follow a standardized approach to implementation and reporting of data.


Asunto(s)
Técnica de Perno Muñón , Fracturas de los Dientes , Humanos , Resinas Compuestas , Análisis del Estrés Dental , Resistencia Flexional , Vidrio , Cementos de Resina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA