Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
ACS Appl Mater Interfaces ; 15(16): 19989-19996, 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37040527

RESUMEN

We present the concept of a versatile drug-loaded composite hydrogel that can be activated using an argon-based cold atmospheric plasma (CAP) jet to deliver both a drug and CAP-generated molecules, concomitantly, in a tissue target. To demonstrate this concept, we utilized the antibiotic gentamicin that is encapsulated in sodium polyacrylate (PAA) particles, which are dispersed within a poly(vinyl alcohol) (PVA) hydrogel matrix. The final product is a gentamicin-PAA-PVA composite hydrogel suitable for an on-demand triggered release using CAP. We show that by activating using CAP, we can effectively release gentamicin from the hydrogel and also eradicate the bacteria effectively, both in the planktonic state and within a biofilm. Besides gentamicin, we also successfully demonstrate the applicability of the CAP-activated composite hydrogel loaded with other antimicrobial agents such as cetrimide and silver. This concept of a composite hydrogel is potentially adaptable to a range of therapeutics (such as antimicrobials, anticancer agents, and nanoparticles) and activatable using any dielectric barrier discharge CAP device.


Asunto(s)
Hidrogeles , Gases em Plasma , Hidrogeles/farmacología , Antibacterianos/farmacología , Alcohol Polivinílico , Gentamicinas/farmacología
2.
J Laryngol Otol ; 137(8): 866-872, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36217672

RESUMEN

BACKGROUND: This study primarily assessed ENT surgical trainees' preferences for the qualities of disposable and reusable fibre-optic nasendoscopes. Secondary aims included eliciting trainees' views on ENT surgery and climate change, and creating a single-centre per-use cost analysis for disposable and reusable fibre-optic nasendoscopes. METHODS: A cross-sectional study was formulated. An online survey consisting of multiple-choice and Likert-scale questions was distributed nationally. Cost analysis was performed using 2021-2022 data from the host institution. RESULTS: Twenty-four trainees responded. Data on disposable fibre-optic nasendoscopes showed no difference in overall satisfaction (p = 0.244). Reusable fibre-optic nasendoscopes had a lower cost per use compared with disposable nasendoscopes at 5 years (4.7 per cent reduction) and 10 years (7.1 per cent reduction). Of the trainees, 79.2 per cent were supportive of climate-friendly initiatives within ENT surgery, and 25 per cent felt supported by their departments. CONCLUSION: Trainees' satisfaction with disposable and reusable fibre-optic nasendoscopes is similar. Cost analysis favours reusable fibre-optic nasendoscopes in the long term at the host institution. Empowering departments and trainees to pursue climate-friendly initiatives should be encouraged.


Asunto(s)
Equipos Desechables , Equipo Reutilizado , Humanos , Estudios Transversales , Costos y Análisis de Costo , Reino Unido
3.
J Laryngol Otol ; 137(6): 622-628, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35912870

RESUMEN

OBJECTIVE: This study aimed to assess the effectiveness of an ENT simulation course for equipping foundation doctors with core ENT skills in preparation for an ENT senior house officer post. METHOD: A total of 41 foundation doctors in the East of England participated in our two-part simulation course. Pre- and post-course surveys, consisting of Likert scales and a Dundee Ready Educational Environment Measure, were sent to assess confidence in core ENT skills and acceptability of course format. RESULTS: Post-simulation, confidence improved in all core ENT skills taught (p < 0.001), along with confidence and preparedness to work as an ENT senior house officer (p < 0.001). Overall course median Dundee Ready Educational Environment Measure score was 48, and 100 per cent of participants would recommend this course to colleagues. CONCLUSION: Simulation improves foundation doctors' confidence in core ENT skills and increases preparedness for working as an ENT senior house officer. Guidance on core ENT skills requirements should be made available to improve uniformity amongst ENT simulation courses.


Asunto(s)
Otolaringología , Humanos , Otolaringología/educación , Competencia Clínica , Cuerpo Médico de Hospitales/educación , Curriculum , Inglaterra , Encuestas y Cuestionarios , Enseñanza
4.
Biosens Bioelectron ; 197: 113775, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34781179

RESUMEN

Catheter-associated urinary tract infections resulting from urease-positive microorganisms are more likely to cause a urinary catheter blockage owing to the urease activity of the microbes. Catheter blockage can be dangerous and increases the risk of severe infections, such as sepsis. Ureases, a virulence factor in Proteus mirabilis, cause an increase in urine pH - leading to blockage. An optimised biosensor "lozenge" is presented here, which is able to detect impending catheter blockage. This lozenge has been optimised to allow easy manufacture and commercialisation. It functions as a sensor in a physiologically representative model of a catheterised urinary tract, providing 6.7 h warning prior to catheter blockage. The lozenge is stable in healthy human urine and can be sterilized for clinical use by ethylene oxide. Clinically, the lozenge will provide a visible indication of impending catheter blockage, enabling quicker clinical intervention and thus reducing the morbidity and mortality associated with blockage.


Asunto(s)
Técnicas Biosensibles , Infecciones por Proteus , Infecciones Urinarias , Biopelículas , Humanos , Proteus mirabilis , Catéteres Urinarios/efectos adversos , Infecciones Urinarias/diagnóstico
5.
Mutagenesis ; 36(5): 380-387, 2021 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-34459491

RESUMEN

The main bactericidal components of cold atmospheric plasma (CAP) are thought to be reactive oxygen and nitrogen species (RONS) and UV-radiation, both of which have the capacity to cause DNA damage and mutations. Here, the mutagenic effects of CAP on Escherichia coli were assessed in comparison to X- and UV-irradiation. DNA damage and mutagenesis were screened for using a diffusion-based DNA fragmentation assay and modified Ames test, respectively. Mutant colonies obtained from the latter were quantitated and sequenced. CAP was found to elicit a similar mutation spectrum to X-irradiation, which did not resemble that for UV implying that CAP-produced RONS are more likely the mutagenic component of CAP. CAP treatment was also shown to promote resistance to the antibiotic ciprofloxacin. Our data suggest that CAP treatment has mutagenic effects that may have important phenotypic consequences.


Asunto(s)
Escherichia coli/efectos de los fármacos , Escherichia coli/genética , Mutágenos/farmacología , Mutación/efectos de los fármacos , Gases em Plasma/farmacología , Daño del ADN/efectos de los fármacos , Fragmentación del ADN , Relación Dosis-Respuesta a Droga , Farmacorresistencia Bacteriana , Mutagénesis/efectos de los fármacos , Rayos Ultravioleta , Rayos X
6.
Sci Rep ; 11(1): 3726, 2021 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-33580163

RESUMEN

Infection and blockage of indwelling urinary catheters is significant owing to its high incidence rate and severe medical consequences. Bacterial enzymes are employed as targets for small molecular intervention in human bacterial infections. Urease is a metalloenzyme known to play a crucial role in the pathogenesis and virulence of catheter-associated Proteus mirabilis infection. Targeting urease as a therapeutic candidate facilitates the disarming of bacterial virulence without affecting bacterial fitness, thereby limiting the selective pressure placed on the invading population and lowering the rate at which it will acquire resistance. We describe the design, synthesis, and in vitro evaluation of the small molecular enzyme inhibitor 2-mercaptoacetamide (2-MA), which can prevent encrustation and blockage of urinary catheters in a physiologically representative in vitro model of the catheterized urinary tract. 2-MA is a structural analogue of urea, showing promising competitive activity against urease. In silico docking experiments demonstrated 2-MA's competitive inhibition, whilst further quantum level modelling suggests two possible binding mechanisms.


Asunto(s)
Amidinas/uso terapéutico , Infecciones por Proteus/tratamiento farmacológico , Proteus mirabilis/enzimología , Ureasa/antagonistas & inhibidores , Cateterismo Urinario/efectos adversos , Infecciones Urinarias/tratamiento farmacológico , Amidinas/farmacología , Células HaCaT , Humanos , Simulación del Acoplamiento Molecular , Terapia Molecular Dirigida , Pruebas de Toxicidad , Infecciones Urinarias/microbiología
7.
Chem Commun (Camb) ; 55(100): 15129-15132, 2019 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-31788680

RESUMEN

Here, a reaction-based indicator displacement hydrogel assay (RIA) was developed for the detection of hydrogen peroxide (H2O2) via the oxidative release of the optical reporter Alizarin Red S (ARS). In the presence of H2O2, the RIA system displayed potent biofilm inhibition for Methicillin-resistant Staphylococcus aureus (MRSA), as shown through an in vitro assay quantifying antimicrobial efficacy. This work demonstrated the potential of H2O2-responsive hydrogels containing a covalently bound diol-based drug for controlled drug release.


Asunto(s)
Antraquinonas/química , Antibacterianos/farmacología , Biopelículas/efectos de los fármacos , Peróxido de Hidrógeno/química , Staphylococcus aureus Resistente a Meticilina/fisiología , Antraquinonas/farmacología , Antibacterianos/química , Escherichia coli/efectos de los fármacos , Hidrogeles/química , Hidrogeles/farmacología , Pruebas de Sensibilidad Microbiana , Pseudomonas aeruginosa/efectos de los fármacos , Solubilidad
8.
J Biomed Mater Res B Appl Biomater ; 107(1): 129-137, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29520965

RESUMEN

It is becoming increasingly accepted that to understand and model the bacterial colonization and infection of abiotic surfaces requires the use of a biofilm model. There are many bacterial colonizations by at least two primary species, however this is difficult to model in vitro. This study reports the development of a simple mixed-species biofilm model using strains of two clinically significant bacteria: Staphylococcus aureus and Pseudomonas aeruginosa grown on nanoporous polycarbonate membranes on nutrient agar support. Scanning electron microscopy revealed the complex biofilm characteristics of two bacteria blending in extensive extracellular matrices. Using a prototype wound dressing which detects cytolytic virulence factors, the virulence secretion of 30 single and 40 mixed-species biofilms was tested. P. aeruginosa was seen to out-compete S. aureus, resulting in a biofilm with P. aeruginosa dominating. In situ growth of mixed-species biofilm under prototype dressings showed a real-time correlation between the viable biofilm population and their associated virulence factors, as seen by dressing fluorescent assay. This paper aims to provide a protocol for scientists working in the field of device related infection to create mixed-species biofilms and demonstrate that such biofilms are persistently more virulent in real infections. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 107B: 129-137, 2019.


Asunto(s)
Bacterias , Infecciones Bacterianas/metabolismo , Fenómenos Fisiológicos Bacterianos , Biopelículas/crecimiento & desarrollo , Contaminación de Equipos , Membranas Artificiales , Modelos Biológicos , Bacterias/crecimiento & desarrollo , Bacterias/patogenicidad , Porosidad , Factores de Virulencia/metabolismo
9.
ACS Sens ; 3(3): 612-617, 2018 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-29443508

RESUMEN

Formation of crystalline biofilms following infection by Proteus mirabilis can lead to encrustation and blockage of long-term indwelling catheters, with serious clinical consequences. We describe a simple sensor, placed within the catheter drainage bag, to alert of impending blockage via a urinary color change. The pH-responsive sensor is a dual-layered polymeric "lozenge", able to release the self-quenching dye 5(6)-carboxyfluorescein in response to the alkaline urine generated by the expression of bacterial urease. Sensor performance was evaluated within a laboratory model of the catheterized urinary tract, infected with both urease positive and negative bacterial strains under conditions of established infection, achieving an average "early warning" of catheter blockage of 14.5 h. Signaling only occurred following infection with urease positive bacteria. Translation of these sensors into a clinical environment would allow appropriate intervention before the occurrence of catheter blockage, a problem for which there is currently no effective control method.


Asunto(s)
Colorantes Fluorescentes/química , Infecciones por Proteus/diagnóstico por imagen , Proteus mirabilis/aislamiento & purificación , Catéteres Urinarios/microbiología , Humanos , Concentración de Iones de Hidrógeno
10.
Clin Radiol ; 54(3): 179-81, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10201868

RESUMEN

The imaging appearances of three patients with a giant sigmoid diverticulum are described. The prominent feature was a large gaseous lucency noted in the lower abdomen on plain radiographs. Computed tomography (CT) was undertaken in two cases and in these a large gas filled collection was identified containing a small quantity of fluid. In the third case the collection was aspirated, contrast medium injected and a communication with the large bowel demonstrated. The condition is uncommon and needs to be distinguished from sigmoid and caecal volvulus.


Asunto(s)
Divertículo del Colon/diagnóstico por imagen , Enfermedades del Sigmoide/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA