2.
BMC Oral Health ; 23(1): 339, 2023 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-37248469

RESUMEN

BACKGROUND: A thorough understanding of root and canal anatomy is crucial for successful root canal treatment outcomes. This systematic review aims to explore the published micro-CT studies investigated the anatomy of root and canal system in permanent mandibular first molars. METHOD: An electronic search was performed on Web of science, PubMed, and Scopus. Micro-CT journal studies investigated the root and canal anatomy of permanent double-rooted mandibular first molars were included. Data on study characteristics, objectives of interest, specifications of the studies, and micro-CT specifications were extracted. Risk of bias assessment (ROB) of the included studies was performed using Anatomical Quality Assessment (AQUA) tool. The extracted data were presented in tables and figures to present and synthesise the results. A meta-analysis was performed for the studies related to the prevalence of Vertucci's canal configurations, middle mesial canal (MMC) configurations, and Fan's isthmus types. RESULTS: Amongst 1358 identified studies, thirty met the inclusion criteria. In terms of the objectives, the selected studies showed high anatomical variability in mandibular first molars. Twenty-two (73%), 25 (83%), and 12 (40%) of the studies reported the population/ethnicity, micro-CT specifications, and ethical approval, respectively. 28 (93%) studies did not disclose the method of sample size estimation. In only 6 (20%) of the studies, the authors had calibrated the assessment approaches. Mostly, a potential ROB was reported in domain 1 (objective(s) and subject characteristics) and domain 3 (methodology characterization). Whilst, low risk was reported in domains 2 (study design), 4 (descriptive anatomy), and 5 (reporting of results). The overall ROB was reported to be ''moderate'' in the vast majority of the studies (27/30). Meta-analysis results showed high levels of heterogeneity among the studies related to MMCs (I2 = 86%) and Fan's isthmus (I2 = 87%). As for the root canal configuration, pooled prevalence showed that Vertucci type IV and type I were the most prevalent in mesial and distal root canals, respectively. CONCLUSION: Based on moderate risk of bias level of evidence, micro-CT studies have shown wide range of qualitative and quantitative data presentations of the roots and canals in mandibular first molars. Protocol and registration. The protocol of this systematic review was prospectively registered in the Open Science Framework database ( https://osf.io ) on 2022-06-20 with the registration number 10.17605/OSF.IO/EZP7K.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Raíz del Diente , Humanos , Microtomografía por Rayos X , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Mandíbula/diagnóstico por imagen , Mandíbula/anatomía & histología
3.
Odontology ; 111(4): 759-776, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36864211

RESUMEN

This systematic review evaluated the effects of nano-sized cement particles on the properties of calcium silicate-based cements (CSCs). Using defined keywords, a literature search was conducted to identify studies that investigated properties of nano-calcium silicate-based cements (NCSCs). A total of 17 studies fulfilled the inclusion criteria. Results indicated that NCSC formulations have favourable physical (setting time, pH and solubility), mechanical (push out bond strength, compressive strength and indentation hardness) and biological (bone regeneration and foreign body reaction) properties compared with commonly used CSCs. However, the characterization and verification for the nano-particle size of NCSCs were deficient in some studies. Furthermore, the nanosizing was not limited to the cement particles and a number of additives were present. In conclusion, the evidence available for the properties of CSC particles in the nano-range is deficient-such properties could be a result of additives which may have enhanced the properties of the material.


Asunto(s)
Compuestos de Calcio , Óxidos , Ensayo de Materiales , Compuestos de Calcio/farmacología , Silicatos/farmacología , Cementos Dentales/farmacología , Cementos Dentales/química , Cementos de Ionómero Vítreo , Combinación de Medicamentos
4.
Clin Oral Investig ; 25(11): 6027-6044, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34623506

RESUMEN

OBJECTIVES: To assess related studies and discuss the clinical implications of endodontic access cavity (AC) designs. MATERIALS AND METHODS: A systematic review of studies comparing the fracture resistance and/or endodontic outcomes between different AC designs was conducted in two electronic search databases (PubMed and Web of Science) following the PRISMA guidelines. Study selection, data extraction, and quality assessment were performed. Meta-analyses were undertaken for fracture resistance and root canal detection, with the level of significance set at 0.05 (P = 0.05). RESULTS: A total of 33 articles were included in this systematic review. The global evaluation of the risk of bias in the included studies was assessed as moderate, and the level of evidence was rated as low. Four types of AC designs were categorized: traditional (TradAC), conservative (ConsAC), ultraconservative (UltraAC), and truss (TrussAC). Their impact on fracture resistance, cleaning/disinfection, procedural errors, root canal detection, treatment time, apical debris extrusion, and root canal filling was discussed. Meta-analysis showed that compared to TradAC, (i) there is a significant higher fracture resistance of teeth with ConsAC, TrussAC, or ConsAC/TrussAC when all marginal ridges are preserved (P < 0.05), (ii) there is no significant effect of the type of AC on the fracture resistance of teeth when one or two marginal ridges are lost (P > 0.05), and (iii) there is a significantly higher risk of undetected canals with ConsAC if not assisted by dental operating microscope and ultrasonic troughing (P < 0.05). CONCLUSIONS: Decreasing the AC extent does not necessarily present mechanical and biological advantages especially when one or more surfaces of the tooth structure are lost. To date, the evidence available does not support the application of TrussAC. UltraAC might be applied in limited occasions. CLINICAL RELEVANCE: Maintaining the extent of AC design as small as practical without jeopardizing the root canal treatment quality remains a pragmatic recommendation. Different criteria can guide the practitioner for the optimal extent of AC outline form which varies from case to case.


Asunto(s)
Preparación de la Cavidad Dental , Fracturas de los Dientes , Atención Odontológica , Cavidad Pulpar , Humanos , Metaanálisis como Asunto , Diente Molar , Preparación del Conducto Radicular , Tratamiento del Conducto Radicular , Revisiones Sistemáticas como Asunto
5.
Aust Endod J ; 45(3): 407-413, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30520194

RESUMEN

This systematic review assessed the effect of different root canal instrumentation systems on endotoxin reduction from the root canal system. The literature search was conducted in two electronic databases (PubMed and Scopus) using specific key words. The search strategy followed the PRISMA guidelines. Qualitative synthesis and quantitative synthesis of the data were performed and data interpretation was done based on the guidelines in the Cochrane Handbook. The risk of bias was assessed using Cochrane criteria. The initial search yielded 600 citations, of which three papers met the criteria for inclusion in this review. Studies showed a significant reduction in endotoxin following rotary and reciprocating instrumentation, with no significant differences between them. The meta-analysis showed no statistical significant difference between reciprocation and rotary files (P > 0.05). In conclusion, the instrumentation techniques compared in this review decrease endotoxin content from root canals, with no significant difference between them.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Endotoxinas , Tratamiento del Conducto Radicular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA