Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Radiol Prot ; 37(3): 659-683, 2017 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-28516892

RESUMEN

Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situation in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situation with occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situation in Japan, but we believe such information sharing will be useful in many other countries.


Asunto(s)
Cristalino/efectos de la radiación , Exposición Profesional/normas , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Relación Dosis-Respuesta en la Radiación , Humanos , Japón , Medición de Riesgo
2.
Radiat Prot Dosimetry ; 168(1): 83-91, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25848094

RESUMEN

Dose conformity in thoracic and abdominal ion-beam radiotherapy is degraded by respiratory motion. To improve conformity, an image-guided respiration-gated system can be used in the treatment room. The purpose of this study was to estimate the organ doses and effective doses to patients from an image-guided respiration-gated system. Glass dosemeters were inserted into an adult anthropomorphic phantom and were attached to the surface on the phantom. The phantom was placed on the treatment couch, and the imaging dose from fluoroscopy was evaluated. In addition to the organ doses, the effective doses were also estimated according to the ICRP Publication 103. The irradiation time is over 3-5 min per beam angle. When image acquisition conditions were assumed for thoracic treatment, the effective doses and maximal skin doses were 0.48-0.79 mSv and 5.9-9.9 mGy, respectively. The estimated doses can be the base data for considering radiological protection in the radiotherapy.


Asunto(s)
Radioterapia Guiada por Imagen/métodos , Radioterapia/métodos , Adulto , Antropometría , Calibración , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Fantasmas de Imagen , Fotones , Dosis de Radiación , Radiometría , Valores de Referencia , Respiración , Piel/efectos de la radiación , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA