Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Comput Tomogr ; 14(6): 490-494, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32576456

RESUMEN

BACKGROUND: Pericoronary adipose tissue (PCAT) attenuation has been identified as a marker for cardiovascular risk. The effect of contrast enhancement on fat attenuation is unknown. We aim to compare precontrast coronary scans to postcontrast CCTA for quantification of pericoronary fat volume and attenuation. METHODS: Thin slice pre- and post-contrast studies obtained at 120 kVp, heart rate <60, with no plaque or artifact in the right coronary artery (RCA) were selected. Analysis was limited to pixels -30 Hounsfield units (HU) to -190 HU and from 10 mm to 50 mm distal to the RCA origin at a radial distance equal to the vessel diameter. A subgroup with no plaque across all coronaries was also analyzed. RESULTS: Of 119 study pairs, the average RCA diameter was highly correlated at 3.85 mm (postcontrast) and 3.84 mm (precontrast), r = 0.97, p < 0.0001. The mean attenuation of pre- and postcontrast images was also highly correlated at -87.02 ±â€¯7.15 HU and -82.74 ±â€¯6.54 HU, respectively (r = 0.65, p < 0.0001). Pericoronary fat volume in the -190 to -30 HU range was 396 mm³ lower in the post contrast versus pre-contrast, consistent with higher attenuation (less negative) voxels postcontrast (p < 0.0001). Inter- and intra-reader agreement ranged 95-100% and 90% for precontrast and 85-90% for postcontrast studies, respectively. Subgroup analysis revealed precontrast attenuation -85.59 ±â€¯7.53 HU and postcontrast -82.21 ±â€¯7.15 HU were highly correlated r = 0.67, p < 0.0001. CONCLUSION: Pericoronary fat enhances with iodinated contrast, potentially explaining some of its risk-predictive capabilities. Fat attenuation and volume can be reliably measured from precontrast calcium scans, with volume quantification showing particularly strong correlation. Excellent inter- and intra-reader agreement is also demonstrated.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector , Pericardio/diagnóstico por imagen , Tejido Adiposo/fisiopatología , Adiposidad , Adulto , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Pericardio/fisiopatología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA