Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Acoust Soc Am ; 141(4): 2623, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28464653

RESUMEN

Circular Synthetic Aperture Sonar (CSAS) processing computes coherently Synthetic Aperture Sonar (SAS) data acquired along a circular trajectory. This approach has a number of advantages, in particular it maximises the aperture length of a SAS system, producing very high resolution sonar images. CSAS image reconstruction using back-projection algorithms, however, introduces a dissymmetry in the impulse response, as the imaged point moves away from the centre of the acquisition circle. This paper proposes a sampling scheme for the CSAS image reconstruction which allows every point, within the full field of view of the system, to be considered as the centre of a virtual CSAS acquisition scheme. As a direct consequence of using the proposed resampling scheme, the point spread function (PSF) is uniform for the full CSAS image. Closed form solutions for the CSAS PSF are derived analytically, both in the image and the Fourier domain. The thorough knowledge of the PSF leads naturally to the proposed adapted atom waves basis for CSAS image decomposition. The atom wave deconvolution is successfully applied to simulated data, increasing the image resolution by reducing the PSF energy leakage.

2.
J Clin Neurophysiol ; 23(3): 245-53, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16751725

RESUMEN

SUMMARY: Independent component analysis (ICA) has recently been applied to epileptic seizure in the EEG. In this paper, the authors show how the fundamental axioms required for ICA to be valid are broken. Four common cases of childhood seizure are presented and assessed for stationarity and an eigenvalue analysis is applied. In all cases, for the stationary sections of data the eigenvalue analysis yields results that imply the signals are coming from a source-rich environment, thus yielding ICA inappropriate when applied to the four common types of childhood seizure. The results suggest that it is not appropriate to apply ICA or source localization from independent components in these four common cases of epilepsy, because the spurious independent components determined by ICA could lead to a spurious localization of the epilepsy. If surgery were to follow, it could result in the incorrect treatment of a healthy localized region of the brain.


Asunto(s)
Electroencefalografía , Epilepsia , Análisis de Componente Principal , Epilepsia/clasificación , Epilepsia/diagnóstico , Epilepsia/fisiopatología , Humanos , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA