Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 14539, 2023 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-37666878

RESUMEN

The YFiler Platinum Casework PCR Amplification Kit is a 6-dye multiplex assay that simultaneously amplifies a set of 38 male-specific, Y-chromosome Short Tandem Repeat (YSTR) markers (DYS576, DYS389I, DYS635, DYS389II, DYS627, DYS549, DYS593, DYS645, DYS460, DYS458, DYS19, YGATAH4, DYS448, DYS391, DYS557, DYS522, DYS456, DYS390, DYS438, DYS392, DYS518, DYS444, DYS533, DYS570, DYS437, DYS385, DYS449, DYS643, DYS596, DYS393, DYS439, DYS481, DYF387S1, DYS527, DYS447), three insertion/deletion polymorphic markers (Yindels: rs771783753, rs759551978, rs199815934), and an internal quality control (IQC) system. When compared to the YFiler Platinum PCR Amplification kit for database samples, YFiler Platinum Casework kit was developed to include an improved Primer Mix incorporating a brighter TED dye, an updated internal quality control system, better resolution of large DNA fragments in Applied Biosystems POP-4 Polymer, and reduced female DNA cross-reactivity. Here, we report the results of the developmental validation study which followed the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, population concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Asunto(s)
Platino (Metal) , Proteínas Tirosina Quinasas Receptoras , Humanos , Femenino , Masculino , Reproducibilidad de los Resultados , Fosforilación , Reacción en Cadena de la Polimerasa
2.
Forensic Sci Int Genet ; 53: 102494, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33740707

RESUMEN

The VeriFiler™ Plus PCR Amplification Kit is a 6-dye multiplex assay that simultaneously amplifies a set of 23 autosomal markers (D3S1358, vWA, D16S539, CSF1PO, D6S1043, D8S1179, D21S11, D18S51, D5S818, D2S441, D19S433, FGA, D10S1248, D22S1045, D1S1656, D13S317, D7S820, Penta E, Penta D, TH01, D12S391, D2S1338, and TPOX), a quality indicator system, and two sex-identification markers. Combined, the markers satisfy the requirements of the Chinese National autosomal DNA database as well as expanded CODIS (Combined DNA Index System). The VeriFiler Plus kit was developed with an improved Master Mix which incorporates the brighter TED™ dye, and accommodates a higher sample loading volume thus allowing for increased sensitivity and enabling maximum information recovery from challenging casework samples including touch, degraded, and inhibited samples. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Animales , Degradación Necrótica del ADN , Dermatoglifia del ADN , Femenino , Genética Forense/instrumentación , Genética de Población , Humanos , Masculino , Repeticiones de Microsatélite , Reproducibilidad de los Resultados , Especificidad de la Especie
3.
Forensic Sci Int Genet ; 42: 190-197, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31374458

RESUMEN

The Huaxia™ Platinum Kit for short tandem repeat (STR) amplification was designed to meet the needs of the rapidly growing Chinese forensic database. This PCR multiplex allows simultaneous amplification of the following autosomal loci: D3S1358, vWA, D16S539, CSF1PO, TPOX, D8S1179, D21S11, D18S51, Penta E, D2S441, D19S433, TH01, FGA, D22S1045, D5S818, D13S317, D7S820, D6S1043, D10S1248, D1S1656, D12S391, D2S1338, Penta D and the gender-identification markers Yindel, and AMEL. The Huaxia™ Platinum Kit enables direct amplification from blood and buccal samples stored on treated and untreated paper, and features an optimized PCR protocol that yields time to results in less than 45 min. Developmental validation testing followed SWGDAM guidelines and demonstrated that this assay produces reproducible and accurate results. Studies on 798 individuals in 4 major Chinese ethnic groups produced highly concordant results with other commercially available STR genotyping kits. The validation results demonstrate that the Huaxia™ Platinum Kit is a robust and reliable identification system for forensic DNA databasing applications.


Asunto(s)
Etnicidad/genética , Genética de Población , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa Multiplex/métodos , Animales , Pueblo Asiatico/genética , Análisis Químico de la Sangre , China , Dermatoglifia del ADN , Frecuencia de los Genes , Humanos , Mucosa Bucal/química , Especificidad de la Especie , Manejo de Especímenes
4.
Int J Legal Med ; 132(6): 1555-1573, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29523969

RESUMEN

The GlobalFiler™ PCR Amplification Kit is a single multiplex assay that amplifies a set of 24 markers, which encompass the European Standard Set and CODIS (Combined DNA Index System) recommended composite set of loci. In addition to more loci and a 6-dye chemistry format, the Master Mix has been formulated to allow higher sample loading volume for trace DNA samples. The GlobalFiler™ Kit has been optimized to deliver high performance on casework samples, while also delivering fast thermal cycling, with an amplification time of approximately 80 min. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Asunto(s)
Dermatoglifia del ADN , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Animales , Huesos/química , Degradación Necrótica del ADN , Frecuencia de los Genes , Humanos , Grupos Raciales/genética , Reproducibilidad de los Resultados , Especificidad de la Especie
5.
Forensic Sci Int Genet ; 24: 164-175, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27459350

RESUMEN

Y-chromosomal loci have proven useful in solving investigations where low levels of male DNA are present in a high female DNA background. An intrinsic limitation of Y-STRs compared with autosomal STRs is a reduced power of discrimination due to a lack of recombination throughout most of the Y-chromosome. Thus, in an effort to increase the power of discrimination we have developed a new 6-dye, 27-plex Y-STR system that includes the 17 loci from the Yfiler(®) and Yfiler(®) Direct kits (DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS635 (Y GATA C4), and Y GATA H4) plus three highly polymorphic Y-STR loci (DYS460, DYS481, and DYS533), and seven rapidly mutating Y-STR loci (DYF387S1a/b, DYS449, DYS518, DYS570, DYS576, DYS627) which allow for improved discrimination of related individuals. The Yfiler(®) Plus PCR Amplification Kit is a dual application assay designed to amplify DNA from extracted casework and database samples from storage cards and swab lysates via direct amplification. Compared to the Yfiler PCR Amplification Kit, the new multiplex shows increased discrimination of male lineages and also improved performance in inhibited samples, improved balance in male DNA samples mixed with female DNA at ratios >1:1000, and faster time to results. The Yfiler Plus Kit shows very high concordance to the Yfiler Kit but discordance with the PowerPlex(®) Y23 Kit at the DYS481 locus was observed in 2 out of 30 samples tested. This developmental validation work follows the SWGDAM guidelines and demonstrates that the assay is robust and suitable for use on forensic casework and database samples.


Asunto(s)
Cromosomas Humanos Y , Dermatoglifia del ADN , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/instrumentación , Animales , Femenino , Genotipo , Humanos , Masculino , Grupos Raciales/genética , Especificidad de la Especie
6.
Forensic Sci Int Genet ; 21: 145-57, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26774100

RESUMEN

The quantification of human genomic DNA is a necessary first step in the DNA casework sample analysis workflow. DNA quantification determines optimal sample input amounts for subsequent STR (short tandem repeat) genotyping procedures, as well as being a useful screening tool to identify samples most likely to provide probative genotypic evidence. To better mesh with the capabilities of newest-generation STR analysis assays, the Quantifiler(®) HP and Quantifiler(®) Trio DNA Quantification Kits were designed for greater detection sensitivity and more robust performance with samples that contain PCR inhibitors or degraded DNA. The new DNA quantification kits use multiplex TaqMan(®) assay-based fluorescent probe technology to simultaneously quantify up to three human genomic targets, allowing samples to be assessed for total human DNA, male contributor (i.e., Y-chromosome) DNA, as well as a determination of DNA degradation state. The Quantifiler HP and Trio Kits use multiple-copy loci to allow for significantly improved sensitivity compared to earlier-generation kits that employ single-copy target loci. The kits' improved performance provides better predictive ability for results with downstream, newest-generation STR assays, and their shortened time-to-result allows more efficient integration into the forensic casework analysis workflow.


Asunto(s)
Dermatoglifia del ADN/instrumentación , Dermatoglifia del ADN/métodos , Técnicas de Genotipaje/instrumentación , Técnicas de Genotipaje/métodos , Juego de Reactivos para Diagnóstico , Animales , ADN/análisis , ADN/sangre , ADN/genética , Femenino , Genética Forense/instrumentación , Genética Forense/métodos , Humanos , Masculino , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los Resultados , Especificidad de la Especie
7.
Forensic Sci Int Genet ; 19: 148-155, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26226223

RESUMEN

In order to increase the power of discrimination, reduce the possibility of adventitious matches, and expand global data sharing, the CODIS Core Loci Working Group made a recommendation to expand the CODIS core loci from the "required" 13 loci to 20 plus three additional "highly recommended" loci. The GlobalFiler(®) Express Kit was designed to incorporate all 20 required and 3 highly recommended loci along with a novel male-specific Y insertion/deletion marker. The GlobalFiler(®) Express Kit allows simultaneous amplification of the following loci: D3S1358, vWA, D16S539, CSF1PO, TPOX, Yindel, AMEL, D8S1179, D21S11, D18S51, DYS391, D2S441, D19S433, TH01, FGA, D22S1045, D5S818, D13S317, D7S820, SE33, D10S1248, D1S1656, D12S391, and D2S1338. The kit enables direct amplification from blood and buccal samples stored on paper or swab and the chemistry features an optimized PCR protocol that yields time to results in less than an hour. Developmental validation testing followed SWGDAM guidelines and demonstrated the quality and robustness of the GlobalFiler(®) Express Kit over a number of variables. The validation results demonstrate that the 24-locus multiplex kit is a robust and reliable identification assay as required for forensic DNA typing and databasing.


Asunto(s)
Colorantes/química , Reacción en Cadena de la Polimerasa/instrumentación , Animales , Humanos , Límite de Detección , Nucleótidos/análisis , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los Resultados , Especificidad de la Especie
8.
Forensic Sci Int Genet ; 7(1): 41-51, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22742953

RESUMEN

The AmpFℓSTR(®) NGM SElect™ PCR Amplification Kit is a new 17-plex STR genotyping kit designed for use primarily in forensic casework analysis. The kit was designed to be a counterpart to the AmpFℓSTR(®) NGM™ Kit for laboratories wishing to add the SE33 locus to the new European Standard Set of STR loci. The NGM SElect Kit shares the same primer sets for 16 common loci with the NGM Kit (D10S1248, D3S1358, vWA, D16S539, D2S1338, amelogenin, D8S1179, D21S11, D18S51, D19S433, TH01, FGA, D22S1045, D2S441, D1S1656 and D12S391), with additional primers for the SE33 locus. Developmental validation studies followed the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for STR kit manufacturers and tested several critical areas of kit performance including a sensitivity series, DNA mixtures and inhibited samples. The studies demonstrated that the NGM SElect Kit provides equivalent overall performance to the NGM Kit, but with even greater discriminatory power due to the inclusion of the highly informative SE33 locus.


Asunto(s)
Mapeo Cromosómico , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/instrumentación , ADN/genética , Femenino , Genética de Población , Genotipo , Humanos , Masculino
9.
Forensic Sci Int Genet ; 6(3): 310-6, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21757416

RESUMEN

SE33 is one of the most informative markers in forensic use due to its high power of discrimination. During the course of developing the AmpFℓSTR(®) NGM SElect™ PCR Amplification Kit several SE33 primer designs were screened with one primer pair yielding a high frequency of discordant alleles when compared to the AmpFℓSTR(®) SEfiler Plus™ PCR Amplification Kit. This discordance was mostly specific to samples of African descent with an estimated frequency of 5.1% and was a result of a mobility shift of approximately +0.84nt. The sequence analysis of the affected alleles revealed that the only difference from the wild type sequence was a single nucleotide polymorphism (SNP) outside of the SE33 repeat but within the amplicon of this particular set of experimental primers. In total, we identified three different SNPs all within 9nt of each other, each of which could cause the mobility shift individually. Further characterization of this region via site directed mutagenesis and thermostability measurements strongly suggests that this polymorphic region contains a secondary structure that, when disrupted due to the presence of a variant SNP, results in a mobility shift relative to the wild type sequence. To overcome this problem, the SE33 primers used in the final configuration of the NGM SElect™ Kit avoided the amplification of this polymorphic region yielding in turn results highly concordant with the SEfiler Plus™ Kit.


Asunto(s)
Cartilla de ADN , Electroforesis , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/métodos , Alelos , Población Negra/genética , Dermatoglifia del ADN , Femenino , Genotipo , Humanos , Secuencias Invertidas Repetidas , Masculino , Mutagénesis Sitio-Dirigida , Reacción en Cadena de la Polimerasa/instrumentación , Polimorfismo de Nucleótido Simple , Análisis de Secuencia de ADN , Termodinámica , Población Blanca/genética
10.
J Forensic Sci ; 53(4): 838-52, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18540972

RESUMEN

DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.


Asunto(s)
Degradación Necrótica del ADN , Dermatoglifia del ADN/instrumentación , Reacción en Cadena de la Polimerasa , Amelogenina/genética , Animales , Quelantes , ADN/efectos de los fármacos , Cartilla de ADN , Hemina , Humanos , Sustancias Húmicas , Especificidad de la Especie , Secuencias Repetidas en Tándem
11.
J Forensic Sci ; 52(4): 870-3, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17553078

RESUMEN

The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.


Asunto(s)
Dermatoglifia del ADN/métodos , ADN/genética , Genética Forense/métodos , Repeticiones de Microsatélite/genética , Reacción en Cadena de la Polimerasa/métodos , ADN/química , Dermatoglifia del ADN/normas , Genética Forense/normas , Humanos , Masculino , Reacción en Cadena de la Polimerasa/normas , Análisis de Secuencia de ADN
12.
J Forensic Sci ; 51(5): 1069-73, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17018083

RESUMEN

Stutter products generated during DNA amplification by the polymerase chain reaction (PCR) may complicate mixture interpretation. The PCR amplification of the DYS392 locus typically results in three distinct detectable PCR products: the true allele product (N), a stutter product three bases smaller (N-3), and a reproducible low-level product, three bases larger (N+3). Sequence analysis of the N+3 product demonstrated that its sequence is one TAT repeat longer than the true allele product. Our experiments demonstrated that the quantity of both N-3 and N+3 stutter increased as the allele number increased. The percent stutter also increased as the magnesium concentration was increased in the reaction, as well as when the amount of input DNA was decreased. As both stutter products behave in a similar and reproducible fashion, the same rules that apply to the interpretation of N-3 stutter products in short tandem repeat analysis, can be applied to N+3 stutters. The characterization of the DYS392 N+3 product is the first detailed published study of a stutter product larger than the true allele.


Asunto(s)
Cromosomas Humanos Y , Repeticiones de Trinucleótidos , Cartilla de ADN , Medicina Legal , Humanos , Cloruro de Magnesio , Masculino , Reacción en Cadena de la Polimerasa
14.
J Forensic Sci ; 51(2): 344-8, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16566768

RESUMEN

During an extensive multipopulation study with Y-short tandem repeat (STR) loci, amplified using the AmpFlSTR Yfiler PCR amplification kit, amplification of a 71 bp fragment was observed in 2.32% of the male samples analyzed (N = 3141). By direct sequencing of this fragment, it was determined that the primer binding sequences were identical to those of the DYS456 locus. A T to G single-nucleotide polymorphism (SNP) enabled amplification of the 71 bp fragment. The SNP is located within an X-Y homologous region at Xq21.31 and was observed with the highest frequency within the African American and Sub-Saharan African populations in our study. Presence of SNP on the X chromosome did not interfere with the reliability of typing the DYS456 locus and the other Y-STR loci typeable using the AmpFlSTR Yfiler PCR amplification kit. Full profiles in a mixture of male:female at 1:4000 were obtained using the current configuration of the AmpFlSTR Yfiler kit even in the presence of female DNA containing the G variant.


Asunto(s)
Cromosomas Humanos X , Dermatoglifia del ADN , Polimorfismo de Nucleótido Simple , Secuencias Repetidas en Tándem , Cromosomas Humanos Y , Cartilla de ADN , Femenino , Frecuencia de los Genes , Humanos , Masculino , Mutación , Reacción en Cadena de la Polimerasa , Grupos Raciales/genética , Análisis de Secuencia de ADN
15.
J Forensic Sci ; 51(1): 64-75, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16423225

RESUMEN

In the past 5 years, there has been a substantial increase in the use of Y-short tandem repeat loci (Y-STRs) in forensic laboratories, especially in cases where typing autosomal STRs has met with limited success. The AmpFlSTR Yfiler PCR amplification kit simultaneously amplifies 17 Y-STR loci including the loci in the "European minimal haplotype" (DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, and DYS393), the Scientific Working Group on DNA Analysis Methods (SWGDAM) recommended Y-STR loci (DYS438 and DYS439), and the highly polymorphic loci DYS437, DYS448, DYS456, DYS458, Y GATA H4, and DYS635 (formerly known as Y GATA C4). The Yfiler kit was validated according to the FBI/National Standards and SWGDAM guidelines. Our results showed that full profiles are attainable with low levels of male DNA (below 125 pg) and that under optimized conditions, no detectable cross-reactive products were obtained on human female DNA, bacteria, and commonly encountered animal species. Additionally, we demonstrated the ability to detect male specific profiles in admixed male and female blood samples at a ratio of 1:1000.


Asunto(s)
Cromosomas Humanos Y , Dermatoglifia del ADN/métodos , Secuencias Repetidas en Tándem , Animales , Gatos/genética , Dermatoglifia del ADN/normas , Cartilla de ADN , Perros/genética , Genética de Población , Humanos , Masculino , Pan troglodytes/genética , Reacción en Cadena de la Polimerasa , Grupos Raciales/genética , Reproducibilidad de los Resultados , Especificidad de la Especie
16.
Immunogenetics ; 54(5): 293-300, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12185532

RESUMEN

We have identified three novel, rarely expressed human genes that encode new members of the lipid transfer/lipopolysaccharide binding protein (LT/LBP) gene family based on sequence homology. BPI and other members of the LT/LBP family are structurally related proteins capable of binding phospholipids and lipopolysaccharides. Real-time PCR studies indicate that BPIL1 and BPIL3 are highly expressed in hypertrophic tonsils. In situ hybridization analysis of BPIL2 shows prominent expression in skin specimens from psoriasis patients. BPIL1 and BPIL3 map to Chromosome 20q11; thus, these novel genes form a cluster with BPI and two other members of the LT/LBP gene family on the long arm of human Chr 20. BPIL2maps to Chr 22q13. The exon/intron organization of all three genes is highly conserved with that of BPI, suggesting evolution from a common ancestor.


Asunto(s)
Proteínas Portadoras/genética , Cromosomas Humanos Par 20/genética , Cromosomas Humanos Par 22/genética , Familia de Multigenes , Secuencia de Aminoácidos , Proteínas Portadoras/biosíntesis , Proteínas Portadoras/química , Proteínas Portadoras/fisiología , Mapeo Cromosómico , Clonación Molecular , Sistemas de Computación , ADN Complementario/genética , Evolución Molecular , Perfilación de la Expresión Génica , Humanos , Modelos Moleculares , Datos de Secuencia Molecular , Especificidad de Órganos , Reacción en Cadena de la Polimerasa/métodos , Conformación Proteica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA