Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Orthop Relat Res ; (346): 255-61, 1998 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9577434

RESUMEN

The efficacy of benzalkonium chloride was evaluated as an irrigating solution for the eradication of Staphylococcus aureus from a contaminated orthopaedic wound. Thirty Sprague Dawley rats were randomized into two groups. A stainless steel wire was placed in a lumbar spinous process, and the wound was inoculated with 10(7) or 10(6) colony forming units of Staphylococcus aureus. The wound was irrigated with 1 L of normal saline or 0.1% benzalkonium chloride solution. The animals were sacrificed, and cultures were obtained. Rats inoculated with 10(7) colony forming units of Staphylococcus aureus and irrigated with benzalkonium chloride had a significant decrease in the total number of positive cultures, deep wound cultures, and stainless steel wire cultures. Rats inoculated with 10(6) colony forming units of Staphylococcus aureus and irrigated with benzalkonium chloride also had a significant decrease in the total number of positive cultures, deep wound cultures, and stainless steel wire cultures. In a parallel noninoculation study, histologic evaluation of tissues did not show toxicity in the rats irrigated with benzalkonium chloride. This study shows that benzalkonium chloride is more effective than normal saline as an irrigating agent for eradicating Staphylococcus aureus from a contaminated orthopaedic wound.


Asunto(s)
Antiinfecciosos Locales/uso terapéutico , Compuestos de Benzalconio/uso terapéutico , Infecciones Estafilocócicas/tratamiento farmacológico , Infección de la Herida Quirúrgica/tratamiento farmacológico , Animales , Ratas , Ratas Sprague-Dawley , Infección de la Herida Quirúrgica/patología , Irrigación Terapéutica
2.
Am J Orthop (Belle Mead NJ) ; 26(9): 617-20, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9316724

RESUMEN

Microbiologic samples for culture were obtained from 21 patients during elective removal of fracture-fixation hardware. The hardware was being removed for pain, displacement, nonunion or malunion correction, or patient preference. None of the patients had evidence of infection as determined by medical history, physical examination, white blood count, and sedimentation rate performed on the day of hardware removal. Two sets of culture samples were obtained from each patient: swabs of the wound and of the hardware were obtained and processed by the hospital laboratory. Eleven hardware cultures and nine wound cultures were positive for microbiologic growth. None of the patients was treated with antibiotics, and none developed any problems with wound infection or healing nor any evidence of osteomyelitis. We concluded that positive cultures obtained during hardware removal in the absence of clinical signs of infection are not meaningful.


Asunto(s)
Recuento de Colonia Microbiana , Contaminación de Equipos , Fijación Interna de Fracturas/instrumentación , Adolescente , Adulto , Anciano , Técnicas Bacteriológicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reoperación , Infección de la Herida Quirúrgica/diagnóstico , Infección de la Herida Quirúrgica/microbiología
3.
Clin Orthop Relat Res ; (329): 255-62, 1996 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8769460

RESUMEN

This investigation seeks to determine whether surfactants or detergents can be used to clean and disinfect orthopaedic wounds with implanted hardware. Thus, a stepwise investigation of biocompatible surfactants and detergents was performed to identify an irrigation agent for disinfecting orthopaedic wounds. Bacterial adhesions assays, irrigation studies, and bactericidal assays determined that benzalkonium chloride showed the greatest efficacy. Testing involved stainless steel screws colonized with a preformed biofilm of Staphylococcus epidermidis, Staphylococcus aureus, or Pseudomonas aeruginosa, which were immersed in benzalkonium chloride solutions for various time intervals under static conditions. After 10 minutes, benzalkonium chloride achieved a minimum 4 log kill (10,000-fold) for all 3 strains of bacteria. Additional studies demonstrated that the high mechanical energy of jet irrigation improved the disinfecting properties of this agent. With jet lavage, both 1:1000 and 1:5000 concentrations of benzalkonium chloride achieved a minimum 2 log kill (100-fold) for all 3 bacteria. The results or this study suggest that at tissue compatible concentrations, benzalkonium chloride has significant disinfection properties for in vitro colonized orthopaedic devices, and these properties may be enhanced via jet lavage.


Asunto(s)
Antiinfecciosos Locales/uso terapéutico , Compuestos de Benzalconio/uso terapéutico , Desinfección , Prótesis e Implantes/microbiología , Biopelículas , Humanos , Pruebas de Sensibilidad Microbiana , Ácido Oléico , Ácidos Oléicos/uso terapéutico , Staphylococcus epidermidis , Tensoactivos , Irrigación Terapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA