1.
Ann Emerg Med ; 38(3): 262-7, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11524645

RESUMEN

STUDY OBJECTIVE: We determined whether automated external defibrillators (AEDs) can meet the American Heart Association performance criteria to detect and shock unstable cardiac rhythms (ventricular fibrillation [VF], ventricular tachycardia [VT]) in the setting of an out-of-hospital cardiac arrest. METHODS: AED performance was reviewed for cardiac arrests occurring between January 1, 1995, and December 31, 1997. After every cardiac arrest, data regarding each rhythm analyzed and subsequent response (shock or no shock) were downloaded from the AED memory module. The study paramedic and study physician independently reviewed each case and interpreted cardiac rhythms from downloaded AED data. The emergency medical services medical director resolved all discrepancies in a blinded manner. All cases of out-of-hospital cardiac arrest in which an AED was turned on and a rhythm analyzed were included. The primary objective was the correct identification and defibrillation of VF or VT. Sensitivity, specificity, and predictive values with 95% confidence intervals (CIs) were calculated. Sources of error in AED rhythm management are also described. RESULTS: A total of 3,448 AED rhythms were available for interpretation. Sensitivity and specificity for appropriate AED management of a shockable (VF or VT) rhythm were 81.0% (95% CI 77.9% to 83.8%) and 99.9% (95% CI 99.7% to 100%), respectively. Positive and negative predictive values were 99.6% (95% CI 98.7% to 99.9%) and 95.5% (95% CI 94.7% to 96.2%), respectively. There were 132 errors associated with AED management. Two errors resulted in delivery of an inappropriate shock. In the remaining 130 errors, a shockable rhythm was not shocked. Fifty-five (42.3%) errors were AED dependent, 70 (53.9%) were operator dependent, and 5 (3.9%) were unclassified. CONCLUSION: The AED had high specificity and moderately high sensitivity in detecting and shocking unstable cardiac rhythms in the out-of-hospital setting. Few cardiac rhythms were mismanaged by the AED. Elimination of operator-dependent errors could increase AED sensitivity.


Asunto(s)
Cardioversión Eléctrica/instrumentación , Servicios Médicos de Urgencia , Análisis de Falla de Equipo , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Boston , Reanimación Cardiopulmonar , Paro Cardíaco/diagnóstico , Paro Cardíaco/mortalidad , Paro Cardíaco/terapia , Humanos , Sensibilidad y Especificidad , Análisis de Supervivencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad
2.
Am J Emerg Med ; 3(4): 316-9, 1985 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-4005001

RESUMEN

Microwave heating of intravenous (IV) fluids is a viable alternative to heating by conventional means, such as by blood warmer(s) or an on-site warming oven, for administration to hypothermic patients and trauma victims. Three 1-l bags each of lactated Ringer's solution, normal saline solution, 1/2 normal saline solution, and 5% dextrose in water were packaged in parenteral containers and heated in a microwave oven from room temperature (21 degrees C) to 40-42 degrees C in 3 minutes. Little difference between temperatures of the four solutions was detected at each of five intervals up to two hours after heating for 3 minutes. Samples were taken before and after heating to assess any potential alterations in sodium, potassium, chloride, calcium, glucose, and lactate levels; differences were within the range of variation of the methods used. Though the plasticizer in the polyvinyl chloride containers is stable to microwave heating, data on other components is incomplete.


Asunto(s)
Fluidoterapia/métodos , Microondas , Soluciones , Temperatura Corporal , Calor , Humanos , Hipotermia/terapia , Factores de Tiempo