Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Orthop Sci ; 29(2): 627-631, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36914484

RESUMEN

BACKGROUND: The self-administered foot evaluation questionnaire is a comprehensive measure for assessing the perception of patients regarding their foot-related problems. However, it is currently only available in English and Japanesse. Therefore, this study aimed to cross-culturally adapt the questionnaire to Spanish and assess its psychometric properties. METHODS: The methodology recommended by the International Society for Pharmaco Economics and Outcomes Research for translating and validating patient-reported outcome measures was followed for the Spanish translation. After a pilot study with 10 patients and 10 controls, an observational study was carried out between March and December 2021. The Spanish version of the questionnaire was filled by 100 patients with unilateral foot disorders, and the time spent to complete each questionnaire was recorded. Cronbach's alpha was calculated to analyze the internal consistency of the scale and Pearson's correlation coefficients for the degree of inter-subscale associations. RESULTS: The maximum correlation coefficient for the Physical Functioning, Daily Living, and Social Functioning subscales was 0.768. The inter-subscale correlation coefficients were significant (p < 0.001). Additionally, the value of Cronbach's alpha for the whole scale was 0.894 (95% confidence interval, 0.858-0.924). The values of Cronbach's alpha varied between 0.863 and 0.889 when the value of one of the five subscales was suppressed, which can be considered a measure of good internal consistency. CONCLUSION: The Spanish version of the questionnaire is valid and reliable. The method followed for its transcultural adaptation ensured its conceptual equivalence with the original questionnaire. Health practitioners can use the self-administered foot evaluation questionnaire as a complementary method to assess the interventions performed for ankle and foot disorders among native Spanish speakers; however, further research is necessary to assess its consistency for use by populations from other Spanish-speaking countries.


Asunto(s)
Comparación Transcultural , Extremidad Inferior , Humanos , Proyectos Piloto , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Psicometría/métodos
2.
J Clin Med ; 12(13)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37445403

RESUMEN

Minimally invasive surgery (MIS) is currently used to correct hallux valgus deformities. Most studies reporting on MIS techniques to correct hallux valgus deformities included patients with postoperative complications. These reported complications, with an average rate of 23%, had significant negative effects on the clinical outcomes in this patient population. In the present study, a cohort of 63 women who underwent MIS hallux valgus correction was assessed preoperatively and at a mean follow-up of 1.0, 4.7, and 6.5 years using the American Orthopaedic Foot and Ankle Society (AOFAS) scale and the Manchester Oxford Foot Questionnaire (MOXFQ). The main criterion for inclusion in this cohort was a lack of complications during the entire follow-up period. The results showed significant improvements in both AOFAS and MOXFQ scores between the preoperative and 1-year follow-up assessments. By contrast, clinically small and nonsignificant changes were observed among postoperative follow-up values. The number of enrolled patients needs to be increased in future studies, with different surgeons and techniques included. Nevertheless, our study findings will inform patients about the outcomes they can expect over the years if no complications occur.

3.
J Clin Med ; 11(19)2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-36233550

RESUMEN

There is some controversy regarding the use of one or two hamstring tendons for anterior cruciate ligament reconstruction (ACLR). In this study, two cohorts of 22 male patients underwent an ACLR with hamstring tendon autografts. One cohort was reconstructed through an all-inside technique with the semitendinosus tendon (ST group) and the other with the semitendinosus and gracilis tendons (ST-G group). Anterior tibial translation (ATT), Lysholm, and IKDC scores were assessed preoperatively and five years postoperation. Additionally, isometric knee muscle strength was manually measured in both groups and in another cohort of 22 uninjured control male subjects five years after the operation. There were no significant differences in ATT and Lysholm scores between the operated groups. The IKDC score was lower in the ST-G group than in the ST group­9.57 (CI 14.89−4.25) (p < 0.001). No significant differences between injured and uninjured knees were detected in hamstring to quadriceps ratio strength and quadriceps limb symmetry index of the two operated groups, but the hamstring limb symmetry index was significantly lower in the ST-G group than in the ST and control groups. This study shows that using an ST-G autograft for ACLR yielded less flexor strength and worse results in some patient-reported outcome measures (PROM) than using an ST autograft five years after the operation. The observed results let us suggest that the use of one autograft hamstring tendon for ACLR is clinically preferable to the use of two hamstring tendons.

4.
J Clin Med ; 11(13)2022 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-35806910

RESUMEN

The surgical correction of a hallux valgus (HV) deformity improves radiological parameters and clinical outcomes. However, it is not known how these improvements are related between themselves. In this retrospective study, 73 women were assessed preoperatively and 60 months after HV surgical correction. Several radiological parameters were measured: the hallux valgus angle (HVA), I−II intermetatarsal angle (IMA) and sesamoid position. The functional outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Hallux Metatarsophalangeal-Interphalangeal (HMI) scale, and patient-reported outcomes (PROMs) were recorded with the Manchester−Oxford Foot Questionnaire (MOXFQ). A pre−post-surgery comparison of radiological and clinical values was performed, the correlation among them was studied and the differences pre−post-surgery in the radiological measurements compared with those for the clinical outcomes were studied. The results show that all the radiological parameters, functional outcomes and PROMs improved significantly from their pre-operative values to the follow-up values. Multivariate regression analysis showed a significant relationship (p < 0.001) between the differential pre−post-surgery AOFAS scoring only with two sesamoid position differential pre−post-surgery measures: position of medial sesamoid (PMS) and translation of the first metatarsal head (TMH). However, no significant association was observed between the pre−post-surgery radiological differences and the pre−post-surgery MOXFQ scoring.

5.
Artículo en Inglés | MEDLINE | ID: mdl-34948910

RESUMEN

Little attention has been paid to knee muscle strength after ACL rupture and its effect on prognostic outcomes and treatment decisions. We studied hamstrings (H) and quadriceps (Q) strength correlation with a patient-reported outcome measures score (International Knee Documentation Committee, IKDC), anterior tibial translation (ATT), and time post-injury in 194 anterior cruciate ligament deficient patients (ACLD) who required surgery after a failed rehabilitation program (non-copers). The correlation between knee muscle strength and ATT was also studied in 53 non-injured controls. ACLD patients showed decreased knee muscle strength of both the injured and non-injured limbs. The median (interquartile range) values of the H/Q ratio were 0.61 (0.52-0.81) for patients' injured side and 0.65 (0.57-0.8) for the non-injured side (p = 0.010). The median H/Q ratio for the controls was 0.52 (0.45-0.66) on both knees (p < 0.001, compared with the non-injured side of patients). The H/Q, ATT, and time post-injury were not significantly correlated with the IKDC score. ATT was significantly correlated with the H/Q of the injured and non-injured knees of patients, but not in the knees of the controls. Quadriceps strength and H/Q ratio were significantly correlated with ATT for both limbs of the patients. IKDC score correlated significantly with the quadriceps and hamstrings strengths of the injured limb but not with the H/Q ratio, ATT or time passed after injury.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Lesiones del Ligamento Cruzado Anterior/cirugía , Estudios Transversales , Humanos , Articulación de la Rodilla , Fuerza Muscular , Medición de Resultados Informados por el Paciente
6.
Orthop Traumatol Surg Res ; 107(2): 102790, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33333269

RESUMEN

BACKGROUND: The Tape Locking Screw system (TLS) is a recognised technique used in anterior cruciate ligament reconstruction (ACLR). However, only a few previous studies have reported associated outcomes, all of which had been examined over a short-term period. The aim of this study was to assess the time-dependent changes in the objective and patient-reported outcome measures (PROM) in a group of patients with anterior cruciate ligament deficiency who have been operated on with this technique. HYPOTHESIS: Previously reported satisfactory short-term outcomes following TLS persist for several years after the operation. PATIENTS AND METHODS: This study was a retrospective observational study including 26 patients, who were followed after unilateral ACLR with TLS. Anterior tibial translation (ATT) was measured in both knees using the KT-1000 arthrometer and two PROMs: International Knee Documentation Committee (IKDC) and Lysholm subjective form scores were examined preoperatively, 6 months postoperatively, and annually for 5 years thereafter in all patients. RESULTS: One patient suffered a rupture of the graft, and one patient had a screw loosening. Two patients were lost for follow-up, so 22 patients were the final study group. Median (25-75%) ATT side-to-side differences between the injured and uninjured sides were 4 (3,5-4)mm preoperatively, 0,75 (0-1)mm 1 year postoperatively, and 0,75 (0-1)mm 5 years after the operation (P<0.001). Median (25-75%) IKDC scores were 44.25 (35.6-55.15), 92.55 (87.08-96.6), and 95.4 (90.8-97.7) points preoperatively and 1 year (P<0.001) and 5 years postoperatively, respectively. Median (25-75%) Lysholm scores were 52 (38.75-64.5), 95.5 (94.75-99.25), and 97.5 (95-99) points preoperatively and 1 year (P<0.001) and 5 years postoperatively, respectively. DISCUSSION: ACLR with TLS might already achieve favourable outcomes 1 year postoperatively, when measured objectively (ATT) and with PROMs. These outcomes persist 5 year postoperatively. LEVEL OF EVIDENCE IV: retrospective cohort study.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Lesiones del Ligamento Cruzado Anterior/cirugía , Tornillos Óseos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente , Estudios Retrospectivos , Resultado del Tratamiento
7.
Orthop J Sports Med ; 9(9): 23259671211031652, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35146030

RESUMEN

BACKGROUND: It is not clear whether the mechanical strength of adjustable-loop suspension devices (ALDs) in anterior cruciate ligament (ACL) reconstruction is device dependent and if these constructs are different from those of an interference screw. PURPOSE: To compare the biomechanical differences of 2 types of ALDs versus an interference screw. STUDY DESIGN: Controlled laboratory study. METHODS: ACL reconstruction was performed on porcine femurs and bovine extensor tendons with 3 types of fixation devices: interference screw, UltraButton (UB) ALD, and TightRope (TR) ALD (n = 10 for each). In addition to specimen testing, isolated testing of the 2 ALDs was performed. The loading protocol consisted of 3 stages: preload (static 150 N load for 5 minutes), cyclic load (50-250 N at 1 Hz for 1000 cycles), and load to failure (crosshead speed 50 mm/min). Displacement at different cycles, ultimate failure load, yield load, stiffness, and failure mode were recorded. RESULTS: In specimen testing, displacement of the ALDs at the 1000th cycle was similar (3.42 ± 1.34 mm for TR and 3.39 ± 0.92 mm for UB), but both were significantly lower than that of the interference screw (7.54 ± 3.18 mm) (P < .001 for both). The yield load of the UB (547 ± 173 N) was higher than that of the TR (420 ± 72 N) (P = .033) or the interference screw (386 ± 51 N; P = .013), with no significant difference between the latter 2. In isolated device testing, the ultimate failure load of the TR (862 ± 64 N) was significantly lower than that of the UB (1879 ± 126 N) (P < .001). CONCLUSION: Both ALDs showed significantly less displacement in cyclic loading at ultimate failure than the interference screw. The yield load of the UB was significantly higher than that of the other 2. The ultimate failure occurred at a significantly higher load for UB than it did for TR in isolated device testing. CLINICAL RELEVANCE: Both UB and TR provided stronger fixation than an interference screw. Although difficult to assess, intrinsic differences in the mechanical properties of these ALDs may affect clinical outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA