Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39266422

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) outflow graft obstruction can result in severe clinical deterioration. Underlying mechanisms may vary depending on the location. Outflow graft tamponade due to external compression can be under recognized. Management of this complication varies across institutions and a uniform approach has yet to be elucidated. OBJECTIVES: Report a single center experience with outflow graft tamponade in patients with LVAD with the purpose of developing an optimal algorithm for the diagnosis and treatment of LVAD-related outflow graft tamponade. METHODS AND RESULTS: Retrospective chart review between July 2011 and July 2020. A total of 351 LVADs were implanted at our center, with outflow graft tamponade identified in 26 patients with LVAD. Fourteen (53.8%) had HeartMate II™, 8 (30.8%) had HeartMate3™ and 4 (15.4%) had HeartWare™. Individuals presented with heart failure symptoms, an audible precordial murmur and LVAD alarms after a median duration of 862 days of support (IQR 327 - 1455). Of the 26 patients, 15 (57.7%) underwent mini thoracotomy with outflow graft relief, 4 had percutaneous balloon dilatation and stenting, 2 were bridged directly to transplant and 1 had a pump exchange. No intervention was made on the remaining due to mild symptoms (n = 4). CONCLUSIONS: Conclusions: Outflow graft tamponade is a form outflow graft obstruction with a variable presentation that can result in significant hemodynamic compromise. It is amenable to both surgical and percutaneous interventions that restore LVAD function.

4.
JACC Heart Fail ; 12(5): 893-901, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38276935

RESUMEN

BACKGROUND: Myocardial recovery occurs in patients with advanced heart failure on left ventricular assist device (LVAD) support, but there is the premise that it is rare with uncertain results. OBJECTIVES: The goal of this study was to investigate the incidence and consequence of LVAD explant after myocardial recovery. METHODS: Using the United Network for Organ Sharing registry, LVAD implants in the United States between 2005 and 2020 were tracked until death, transplantation, or explant for myocardial recovery. The cohort undergoing explant was followed up for heart failure relapse (defined as relisting followed by delisting due to death, being too ill, or transplantation; or second durable LVAD implant). RESULTS: Of 15,728 LVAD implants, 126 patients underwent explant for recovery, which only occurred in 55 (38%) of 145 implanting centers. The crude cumulative incidence was 0.7% at 2 years, whereas the incidence reached 4.7% among designated centers in the selected young nonischemic cohort. Of 126 explanted patients, 76 (60%) were subsequently delisted for sustained recovery. Heart failure relapsing had a relatively higher hazard in the early phase, with a 30-day incidence of 6% (7 of 126) but tapered following with the freedom rate of 72.5% at 4 years. CONCLUSIONS: In the United States, LVAD explant for myocardial recovery was underutilized, leading to a very low incidence at the national level despite a realistic rate being achieved in designated centers for selected patients. With follow-up extending up to 4 years after explant, more than one-half were successfully removed and stayed off the waitlist, and approximately 70% were free from heart failure relapse events.


Asunto(s)
Remoción de Dispositivos , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Masculino , Femenino , Persona de Mediana Edad , Incidencia , Estados Unidos/epidemiología , Remoción de Dispositivos/estadística & datos numéricos , Adulto , Recuperación de la Función , Sistema de Registros , Recurrencia , Anciano , Estudios Retrospectivos
6.
J Heart Lung Transplant ; 43(4): 529-538, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37951322

RESUMEN

BACKGROUND: Previous retrospective studies suggest a good diagnostic performance of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/computed tomography (CT) in left ventricular assist device (LVAD) infections. Our aim was to prospectively evaluate the role of PET/CT in the characterization and impact on clinical management of LVAD infections. METHODS: A total of 40 patients (aged 58 [53-62] years) with suspected LVAD infection and 5 controls (aged 69 [64-71] years) underwent 18F-FDG-PET/CT. Four LVAD components were evaluated: exit site and subcutaneous driveline (peripheral), pump pocket, and outflow graft. The location with maximal uptake was considered the presumed site of infection. Infection was confirmed by positive culture (exit site or blood) and/or surgical findings. RESULTS: Visual uptake was present in 40 patients (100%) in the infection group vs 4 (80%) control subjects. For each individual component, the presence of uptake was more frequent in the infection than in the control group. The location of maximal uptake was most frequently the pump pocket (48%) in the infection group and the peripheral components (75%) in the control group. Maximum standard uptake values (SUVmax) were higher in the infection than in the control group: SUVmax (average all components): 6.9 (5.1-8.5) vs 3.8 (3.7-4.3), p = 0.002; SUVmax (location of maximal uptake): 10.6 ± 4.0 vs 5.4 ± 1.9, p = 0.01. Pump pocket infections were more frequent in patients with bacteremia than without bacteremia (79% vs 31%, p = 0.011). Pseudomonas (32%) and methicillin-susceptible Staphylococcus aureus (29%) were the most frequent pathogens and were associated with pump pocket infections, while Staphylococcus epidermis (11%) was associated with peripheral infections. PET/CT affected the clinical management of 83% of patients with infection, resulting in surgical debridement (8%), pump exchange (13%), and upgrade in the transplant listing status (10%), leading to 8% of urgent transplants. CONCLUSIONS: 18F-FDG-PET/CT enables the diagnosis and characterization of the extent of LVAD infections, which can significantly affect the clinical management of these patients.


Asunto(s)
Bacteriemia , Corazón Auxiliar , Infecciones Relacionadas con Prótesis , Humanos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Corazón Auxiliar/efectos adversos , Tomografía Computarizada por Rayos X , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/etiología , Bacteriemia/diagnóstico , Bacteriemia/etiología
7.
J Thorac Cardiovasc Surg ; 167(1): 205-214.e5, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-35618532

RESUMEN

OBJECTIVES: Although the SynCardia total artificial heart (SynCardia Systems, LLC) was approved for use as a bridge to transplantation in 2004 in the United States, most centers do not adopt the total artificial heart as a standard bridging strategy for patients with biventricular failure. This study was designed to characterize the current use and outcomes of patients placed on total artificial heart support. METHODS: The United Network of Organ Sharing Standard Transplant Research File was queried to identify total artificial heart implantation in the United States between 2005 and 2018. Multivariable Cox regression models were used for risk prediction. RESULTS: A total of 471 patients (mean age, 49 years; standard deviation, 13 years; 88% were male) underwent total artificial heart implantation. Of 161 transplant centers, 11 centers had cumulative volume of 10 or more implants. The 6-month cumulative incidence of mortality on the total artificial heart was 24.6%. The 6-month cumulative incidence of transplant was 49.0%. The 1-year mortality post-transplantation was 20.0%. Cumulative center volume less than 10 implants was predictive of both mortality on the total artificial heart (hazard ratio, 2.2, 95% confidence interval, 1.5-3.1, P < .001) and post-transplant mortality after a total artificial heart bridge (hazard ratio, 1.5, 95% confidence interval, 1.0-2.2, P = .039). CONCLUSIONS: Total artificial heart use is low, but the total artificial heart can be an option for biventricular bridge to transplant with acceptable bridge to transplant and post-transplant survival, especially in higher-volume centers. The observation of inferior outcomes in lower-volume centers raises questions as to whether targeted training, center certifications, and minimum volume requirements could improve outcomes for patients requiring the total artificial heart.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Artificial , Humanos , Masculino , Estados Unidos , Persona de Mediana Edad , Femenino , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/cirugía , Incidencia , Estudios Retrospectivos
8.
Surg Endosc ; 37(11): 8655-8662, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37495848

RESUMEN

INTRODUCTION: Patients suffering from advanced heart failure may undergo left ventricular assist device (LVAD) placement as a bridge to cardiac transplantation. However, those with a BMI above 35 kg/m2 are generally not considered eligible for transplant due to their elevated cardiac risk. We review our experience with bariatric surgery in this high-risk population to assess its safety and efficacy in reducing BMI to permit cardiac transplantation. METHODS: We retrospectively reviewed all patients on durable LVAD support who underwent sleeve gastrectomy (SG) at Mount Sinai Hospital between August 2018 and December 2022. Electronic medical records were reviewed to analyze patient demographics, surgical details, and outcomes regarding weight loss and heart transplantation. RESULTS: We identified twelve LVAD patients who underwent SG. Three were performed laparoscopically and 9 via robotic approach. Four patients (33.3%) underwent an orthotopic heart transplant (OHTx). Half of these patients were female. For patients who underwent OHTx, mean age at LVAD placement was 41.0 (R30.6-52.2), at SG was 43.9 (R32.7-55.0) and at OHTx was 45.3 years (R33.3-56.8). Mean BMI increased from 38.8 at LVAD placement to 42.5 prior to SG. Mean time from SG to OHTx was 17.9 months (R6-7-27.5) during which BMI decreased to mean 32.8 at the time of OHTx. At most recent follow-up, mean BMI was 31.9. All patients were anticoagulated prior to surgery; one required return to the operating room on post-operative day 1 after SG for bleeding and one was re-admitted on post-operative day 7 for hematochezia treated conservatively. CONCLUSION: SG is a safe and effective operation in patients with severe obesity and heart failure requiring an LVAD. 66.7% of our cohort achieved target BMI < 35 and 33.3% underwent heart transplantation. Longer term follow-up is needed to clarify full bridge-to-transplant rate and long-term survival outcomes.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Obesidad Mórbida , Humanos , Femenino , Masculino , Obesidad Mórbida/complicaciones , Obesidad Mórbida/cirugía , Estudios Retrospectivos , Obesidad , Insuficiencia Cardíaca/cirugía , Gastrectomía , Pérdida de Peso , Resultado del Tratamiento
9.
Artículo en Inglés | MEDLINE | ID: mdl-37318685

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is now the most common form of heart failure (HF). This syndrome is associated with an elevated morbi-mortality, and effective therapies are urgently needed. Sodium-glucose co-transporter 2 inhibitors (SGLT2i) are the first pharmacological class that has demonstrated to reduce hospitalization and cardiovascular mortality in large clinical trials in HFpEF. Furthermore, the dual SGLT 1/2 inhibitor sotagliflozin has shown a reduction in cardiovascular outcomes in diabetic HF patients, regardless of ejection fraction Sotagliflozin on Cardiovascular Events in Patients with Type 2 Diabetes Post Worsening Heart Failure (SOLOIST-WHF) Trial, and prevents the development of HF in patients with diabetes and chronic kidney disease Sotagliflozin on Cardiovascular and Renal Events in Patients with Type 2 Diabetes and Moderate Renal Impairment Who Are at Cardiovascular Risk (SCORED) trial. The major objective of the Sotagliflozin in Heart Failure With Preserved Ejection Fraction Patients (SOTA-P-CARDIA) trial (NCT05562063) is to investigate whether the observed cardiorenal benefits of sotagliflozin in HF patients with diabetes can be extended to a non-diabetic population. The SOTA-P-CARDIA is a prospective, randomized, double-blinded, placebo-controlled study that will randomize non-diabetic patients with the universal definition of HFpEF (ejection fraction > 50% assessed the day of randomization). Qualifying patients will be randomized, in blocks of 4, to receive either sotagliflozin or placebo for a period of 6 months. The primary outcome is changes in left ventricular mass by cardiac magnetic resonance from randomization to end of the study between the groups. Secondary end points include changes in peak VO2; myocardial mechanics, interstitial myocardial fibrosis, and volume of epicardial adipose tissue; distance in the 6-min walk test; and quality of life. Finally, the authors expect that this trial will help to clarify the potential benefits of the use of sotagliflozin in non-diabetic HFpEF patients.

10.
ASAIO J ; 69(6): 544-551, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36867839

RESUMEN

INTRODUCTION: The SynCardia total artificial heart (TAH) is the only device approved for biventricular support. Continuous flow ventricular assist devices (VAD) in a biventricular configuration (BiVAD) have been used with variable results. The purpose of this report was to examine differences in patient characteristics and outcomes between two HeartMate-3 (HM-3) VADs in comparison with TAH support. METHODS: All patients who received durable biventricular mechanical support from November 2018 to May 2022 at The Mount Sinai Hospital (New York) were considered. Baseline clinical, echocardiographic, hemodynamic, and outcome data were extracted. Primary outcomes were postoperative survival and successful bridge-to-transplant (BTT). RESULTS: A total of 16 patients received durable biventricular mechanical support during the study period, of which 6 (38%) patients received two HM-3 VAD pumps as BiVAD support and 10 (62%) patients received a TAH. Overall, TAH patients had a lower median lactate ( p < 0.05) at baseline compared to those on HM-3 BiVAD support yet had higher operative morbidity, lower 6-month survival ( p < 0.05), and a higher rate of renal failure (80 vs . 17%; p = 0.03). However, survival declined to the same rate at 1 year (50%) and was largely because of extracardiac adverse events related to underlying comorbidities (particularly, renal failure and diabetes, p < 0.05). Successful BTT was achieved in 3 out of 6 HM-3 BiVAD patients and in 5 out of 10 TAH patients. CONCLUSION: In our single center experience, similar outcomes were observed among patients BTT with HM-3 BiVAD compared to those BTT on TAH support despite lower Interagency Registry for Mechanically Assisted Circulatory Support level.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Artificial , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Hemodinámica , Resultado del Tratamiento , Estudios Retrospectivos
11.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36950852

RESUMEN

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Fibrilación Atrial/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/complicaciones , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos
12.
J Am Coll Cardiol ; 81(8): 729-740, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36813371

RESUMEN

BACKGROUND: Simultaneous heart-kidney transplantation has been increasingly performed in end-stage heart failure patients with concurrent kidney dysfunction despite limited evidence supporting its indications and utility. OBJECTIVES: The purpose of this study was to investigate the effects and utility of simultaneously implanted kidney allografts with various degrees of kidney dysfunction during heart transplantation. METHODS: Using the United Network for Organ Sharing registry, long-term mortality was compared in recipients with kidney dysfunction who underwent heart-kidney transplantation (n = 1,124) vs isolated heart transplantation (n = 12,415) in the United States between 2005 and 2018. In heart-kidney recipients, contralateral kidney recipients were compared for allograft loss. Multivariable Cox regression was used for risk adjustment. RESULTS: Long-term mortality was lower among heart-kidney recipients than among heart-alone recipients when recipients were on dialysis (26.7% vs 38.6% at 5 years; HR: 0.72; 95% CI: 0.58-0.89) or had a glomerular filtration rate (GFR) of <30 mL/min/1.73 m2 (19.3% vs 32.4%; HR: 0.62; 95% CI: 0.46-0.82) and GFR of 30 to 45 mL/min/1.73 m2 (16.2% vs 24.3%; HR: 0.68; 95% CI: 0.48-0.97) but not in GFR of 45 to 60 mL/min/1.73 m2. Interaction analysis showed that the mortality benefit of heart-kidney transplantation continued up to GFR 40 mL/min/1.73 m2. The incidence of kidney allograft loss was higher among heart-kidney recipients than among contralateral kidney recipients (14.7% vs 4.5% at 1 year; HR: 1.7; 95% CI: 1.4-2.1). CONCLUSIONS: Heart-kidney transplantation relative to heart transplantation alone provided superior survival for dialysis-dependent recipients and non-dialysis-dependent recipients up to a GFR of approximately 40 mL/min/1.73 m2 but at the cost of almost twice the risk of kidney allograft loss than contralateral kidney allograft recipients.


Asunto(s)
Trasplante de Corazón , Trasplante de Riñón , Insuficiencia Renal , Humanos , Estados Unidos , Riñón , Tasa de Filtración Glomerular , Estudios Retrospectivos , Supervivencia de Injerto
14.
Nat Rev Cardiol ; 20(4): 263-277, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36357709

RESUMEN

Originally intended for life-saving salvage therapy, the use of temporary mechanical circulatory support (MCS) devices has become increasingly widespread in a variety of clinical settings in the contemporary era. Their use as a short-term, prophylactic support vehicle has expanded to include procedures in the catheterization laboratory, electrophysiology suite, operating room and intensive care unit. Accordingly, MCS device design and technology continue to develop at a rapid pace. In this Review, we describe the functionality, indications, management and complications associated with temporary MCS, together with scenario-specific utilization, goal-directed development and bioengineering of future devices. We address various considerations for the use of temporary MCS devices in both prophylactic and rescue scenarios, with input from stakeholders from various cardiovascular specialties, including interventional and heart failure cardiology, electrophysiology, cardiothoracic anaesthesiology, critical care and cardiac surgery.


Asunto(s)
Cardiología , Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Corazón , Choque Cardiogénico/terapia
15.
ASAIO J ; 69(1): 43-49, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36583770

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic continues to pose a significant threat to patients receiving advanced heart failure therapies. The current study was undertaken to better understand the relationship between obesity and outcomes of SARS-CoV-2 infection in patients with a left ventricular assist device (LVAD) or heart transplant. We performed a retrospective review of patients with a heart transplant or LVAD who presented to one of the participating 11 institutions between April 1 and November 30, 2020. Patients were grouped by body mass index (BMI) into obese (BMI ≥ 30 k/m2) and nonobese cohorts (BMI < 30 kg/m2). Multivariable logistic regression models were used to estimate effects of obesity on outcomes of interest. Across all centers, 162 heart transplant and 81 LVAD patients were identified; 54 (33%) and 38 (47%) were obese, respectively. Obese patients tended to have more symptoms at presentation. No differences in rates of hospitalization or ICU admission were noted. Obese patients with LVADs were more likely to require mechanical ventilation (39% vs. 8%, p < 0.05). No differences in renal failure or secondary infection were noted. Mortality was similar among heart transplant patients (11% [obese] vs. 16% [nonobese], p = 0.628) and LVAD patients (12% vs. 15%, p = 1.0). BMI was not associated with increased adjusted odds of mortality, ICU admission, or mechanical ventilation (all p > 0.10). In summary, acute presentations of SARS-CoV-2 among heart transplant and LVAD recipients carry a significantly higher mortality than the general population, although BMI does not appear to impact this. Further studies on the longer-term effects of COVID-19 on this population are warranted.


Asunto(s)
COVID-19 , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Índice de Masa Corporal , COVID-19/complicaciones , SARS-CoV-2 , Trasplante de Corazón/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Obesidad/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento
18.
Transpl Immunol ; 72: 101567, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35278648

RESUMEN

INTRODUCTION: We examined the impact and time course of de novo human leukocyte antigen (HLA) allosensitization following left ventricular assist device (LVAD) implantation. METHODS AND RESULTS: Forty patients had a calculated panel reactive antibody (cPRA) prior to LVAD surgery between January 2014 and December 2018. Of these patients, we retrospectively studied 33 patients who had pre-LVAD cPRA <10%. De novo allosensitization was defined as cPRA ≥10% within 3 months following LVAD surgery, and "persistent allosensitization" was defined as cPRA ≥10% at time of heart transplant or death. One-third (11/33) of our cohort developed de novo allosensitization within 3-months post-LVAD. Median duration of follow-up during LVAD support was 588 days (IQR 337-1071 days), or approximately 19 months. In an adjusted, multivariable analysis, female sex remained associated with de novo allosensitization (adjusted odds ratio [95%CI]: 11 (1.4-85), P = 0.026). De novo allosensitization was subsequently associated with persistent allosensitization (P = 0.024). Both axial-flow and centrifugal-flow LVADs had similar rates of allosensitization. Compared to those with no allosensitization, patients with de novo allosensitization did not appear to have inferior post-transplant outcomes of death or treated rejection. CONCLUSION: In our single-center experience, one-third of patients developed de novo allosensitization which did not appear to associate with inferior post-transplant outcomes. Female sex was associated with de novo allosensitization.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Anticuerpos , Femenino , Antígenos HLA , Antígenos de Histocompatibilidad Clase I , Antígenos de Histocompatibilidad Clase II , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
19.
Artif Organs ; 46(7): 1409-1414, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35083754

RESUMEN

PURPOSE: Driveline infection (DLI) is a significant source of morbidity and mortality during left ventricular assist device (LVAD) support yet limited studies are available to describe the center-level prevalence, preventive practices, and their potential effectiveness. METHODS: We surveyed LVAD centers in the United States to determine program burden and preventive practices for DLI during HeartMate (HM) 3 support. An online, anonymous, question-based survey was sent to expert providers at implanting centers. Only a single respondent completed the survey for each center. As an exploratory analysis, we compared specific DLI preventive practices between centers with low (≤10%) and high (>10%) reported prevalence of DLI. RESULTS: Seventy-eight centers responded to the survey (response rate: 50%). Respondents were comprised of 37 (47%) heart failure cardiologists, 27 (35%) LVAD coordinators, and 14 (18%) cardiothoracic surgeons. The prevalence of DLI during HM3 was reported as ≤10% by 27 (35%), 11%-25% by 36 (46%), and >25% by 16 (19%) centers. Thirteen (17%) centers had a body mass index threshold for device placement, 29 (37%) utilized a counter incision, 66 (81%) placed an anchor stitch, and 69 (88%) used an external device to stabilize the DL. Proportionally, more centers with a low DLI prevalence used a wound vacuum 6 (22%) versus 3 (6%, p = 0.03) than those with high DLI. CONCLUSION: Variation exists in reported prevalence and practices of preventing and managing driveline infections across centers during HM3 support. Further studies are warranted to develop and assess the effectiveness of standardized preventive strategies.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Infecciones Relacionadas con Prótesis , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Estudios Retrospectivos , Encuestas y Cuestionarios
20.
Am Heart J Plus ; 18: 100154, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38559421

RESUMEN

SGLT-2 inhibitors have been shown to confer reduced risk of adverse cardiovascular events in patients with heart failure, and have also been studied preliminarily among heart transplant patients, with overall positive findings. Use of SGLT-2 inhibitors among patients with durable mechanical circulatory support has not been studied. Here we present our results from a combined retrospective cohort of LVAD patients on SGLT-2 inhibitors at two major academic centers, which showed a good safety profile but prompted questions for further investigation. We advocate for further research into the safety and impact of SGLT-2 inhibitors among LVAD patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA