Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Chem ; 17(1): 145, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37891646

RESUMEN

Two simple, accurate and precise chromatographic methods have been developed and validated for estimating Mupirocin (MUP) in two binary mixtures. Mixture (1); with Fluticasone propionate (FLU) together with two of their impurities, namely; Pseudomonic acid-D (Pseud-D) and Fluticasone impurity C (FIC). Mixture (2); with Mometasone furoate (MF) along with Pseud-D impurity. High performance thin layer chromatography (HPTLC-densitometry) and high performance liquid chromatography (RP-HPLC) were the two proposed methods. In the HPTLC method, good separation of both mixtures was achieved by using HPTLC plates pre-coated with silica gel 60 F254 as stationary phase and the mobile phase consisted of toluene: chloroform: ethanol at a ratio of (5: 4: 2, by volume). The detection was carried out at 220 nm for MUP and 254 nm for FLU, MF, Pseud-D and FIC. In the HPLC method, chromatographic separation was carried out using Agilent Eclipse XDB (250 mm×4.6 mm, 5 µm) C18 column. For mixture (1), a mobile phase of methanol: sodium di-hydrogen phosphate (pH 3.0) was applied in stepwise gradient elution starting at ratios of (50: 50, v/v) and then switching to (80: 20, v/v) after 7 min at a flow rate of 1 mL.min- 1. Detection was performed using diode array detector at 220 nm for MUP and Pseud-D and 240 nm for FLU and FIC. For mixture (2), the same mobile phase was used, but in isocratic elution in the ratio (80: 20, v/v) at flow rate of 1 mL.min- 1 and detection at 220 nm for MUP and Pseud-D and 248 nm for MF. The two methods successfully separated the cited drugs and were used to determine the drugs in pure form as well as pharmaceutical dosage forms. Validation was done as per International Council on Harmonization guidelines. Furthermore, the greenness of the proposed methods compared to the reported method, was evaluated as per the National Environmental Method Index, analytical Eco scale, Green Analytical Procedure Index and Analytical Greenness metric approaches.

2.
J Chromatogr Sci ; 61(6): 546-551, 2023 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-35750039

RESUMEN

In this work, two chromatographic methods are developed and validated for the determination of enrofloxacin and bromhexine (BRM) HCl in the presence of two of their specified impurities, ciprofloxacin and BRM impurity C. The suggested chromatographic methods included the use of thin layer chromatography (TLC-densitometry) and high-performance liquid chromatography (HPLC). In case of TLC-densitometry, good separation was achieved by using mobile phase of n.butanol:acetone:water:glacial acetic acid:triethylamine (10:3:1:0.5:0.5, by volume) on silica gel stationary phase at 254-nm detection. The developed HPLC method used BDS HYPERSIL C18 column with a mobile phase of water:acetonitrile:methanol:triflouroacetic acid. A linear gradient elution of 75-10%, 20-50% and 5-40% for water, acetonitrile and methanol, respectively, was applied in 13 min at a flow rate of 1.5 mL min-1. These methods were sufficient to separate the four substances simultaneously, and they are validated as per International Conference on Harmonization guidelines.


Asunto(s)
Cromatografía Líquida de Alta Presión , Cromatografía en Capa Delgada/métodos , Cromatografía Líquida de Alta Presión/métodos , Bromhexina/química , Bromhexina/aislamiento & purificación , Enrofloxacina/química , Enrofloxacina/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA