Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(5): 831-842, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35174572

RESUMEN

INTRODUCTION: A wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort. METHODS: One hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false-positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient-day). RESULTS: Of 163 WCD episodes, 4 were VT/VF and 159 non-VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false-positive shock alarm markers were recorded; one false-positive shock alarm every 1333 patient-days (0.00075 per patient-day, 95% confidence interval: 0.00015-0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient-days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%). CONCLUSION: The ASSURE WCD demonstrated a low false-positive shock alarm rate, low patient-reported discomfort, and no serious adverse events.


Asunto(s)
Desfibriladores Implantables , Dispositivos Electrónicos Vestibles , Arritmias Cardíacas , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Humanos , Volumen Sistólico , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia , Función Ventricular Izquierda
2.
Europace ; 23(3): 451-455, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33432349

RESUMEN

AIMS: The novel coronavirus SARS-CoV-2 has shown the potential to significantly affect the cardiovascular system. Cardiac arrhythmias are commonly reported complications in COVID-19 hospitalized patients. METHODS AND RESULTS: While tachyarrhythmias seem most common, we describe four cases of COVID-19 patients who developed a transient high-degree atrioventricular (AV) block during the course of their hospitalization. All four patients who developed a high-degree AV block during their hospitalization with COVID-19 did not require permanent pacing. CONCLUSION: Similarly to most AV blocks associated with infectious organisms and given its transient nature, this case series suggests that conservative management strategies should be preferred in COVID-19 patients who develop complete heart block.


Asunto(s)
Bloqueo Atrioventricular/etiología , Nodo Atrioventricular/fisiopatología , COVID-19/complicaciones , Frecuencia Cardíaca , Hospitalización , Potenciales de Acción , Adulto , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/terapia , Tratamiento Conservador , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 74(16): 2047-2055, 2019 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-31623762

RESUMEN

BACKGROUND: Increased pre-hospital delay during acute coronary syndrome (ACS) events contributes to worse outcome. OBJECTIVES: The purpose of this study was to assess the effectiveness of an implanted cardiac monitor with real-time alarms for abnormal ST-segment shifts to reduce pre-hospital delay during ACS events. METHODS: In the ALERTS (AngeLmed Early Recognition and Treatment of STEMI) pivotal study, subjects at high risk for recurrent ACS events (n = 907) were randomized to control (Alarms OFF) or treatment groups for 6 months, after which alarms were activated in all subjects (Alarms ON). Emergency department (ED) visits with standard-of-care cardiac test results were independently adjudicated as true- or false-positive ACS events. Alarm-to-door (A2D) and symptom-to-door (S2D) times were calculated for true-positive ACS ED visits triggered by 3 possible prompts: alarm only, alarms + symptoms, or symptoms only. RESULTS: The Alarms ON group showed reduced delays, with 55% (95% confidence interval [CI]: 46% to 63%) of ED visits for ACS events <2 h compared with 10% (95% CI: 2% to 27%) in the Alarms OFF group (p < 0.0001). Results were similar when restricted to myocardial infarction (MI) events. Median pre-hospital delay for MI was 12.7 h for Alarms OFF and 1.6 h in Alarms ON subjects (p < 0.0089). Median A2D delay was 1.4 h for asymptomatic MI. Median S2D delay for symptoms-only MI (no alarm) in Alarms ON was 4.3 h. CONCLUSIONS: Intracardiac monitoring with real-time alarms for ST-segment shift that exceeds a subject's self-normative ischemia threshold level significantly reduced the proportion of pre-hospital delays >2 h for ACS events, including asymptomatic MI, compared with symptoms-only ED visits in Alarms OFF. (AngeLmed for Early Recognition and Treatment of STEMI [ALERTS]; NCT00781118).


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Alarmas Clínicas , Tiempo de Tratamiento , Adulto , Anciano , Servicio de Urgencia en Hospital , Reacciones Falso Positivas , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/terapia , Estudios Prospectivos , Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 73(15): 1919-1927, 2019 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-30842028

RESUMEN

BACKGROUND: Symptoms remain a poor prompt for acute coronary syndromes (ACS). Timely restoration of perfusion in ST-segment elevation myocardial infarction is associated with improved left ventricular function and survival. OBJECTIVES: This report details the results of ALERTS (AngelMed for Early Recognition and Treatment of STEMI), a multicenter, randomized trial of an implantable cardiac monitor that alerts patients with rapidly progressive ST-segment deviation. METHODS: High-risk ACS subjects (N = 907) were randomized to a control (alarms deactivated) or treatment group for 6 months, after which alarms were activated in all subjects. The primary safety endpoint was absence of system-related complications (>90%). The composite primary efficacy endpoint was cardiac/unexplained death, new Q-wave myocardial infarction, or detection to presentation time >2 h. RESULTS: Safety was met with 96.7% freedom from system-related complications (n = 30). The efficacy endpoint for a confirmed occlusive event within 7 days was not significantly reduced in the treatment compared with control group (16 of 423 [3.8%] vs. 21 of 428 [4.9%], posterior probability = 0.786). Within a 90-day window, alarms significantly decreased detection to arrival time at a medical facility (51 min vs. 30.6 h; Pr [pt < pc] >0.999). In an expanded analysis using data after the randomized period, positive predictive value was higher (25.8% vs. 18.2%) and false positive rate significantly lower in the ALARMS ON group (0.164 vs. 0.678 false positives per patient-year; p < 0.001). CONCLUSIONS: The implantable cardiac system detects early ST-segment deviation and alerts patients of a potential occlusive event. Although the trial did not meet its pre-specified primary efficacy endpoint, results suggest that the device may be beneficial among high-risk subjects in potentially identifying asymptomatic events. (AngelMed for Early Recognition and Treatment of STEMI [ALERTS]; NCT00781118).


Asunto(s)
Síndrome Coronario Agudo/prevención & control , Desfibriladores Implantables , Diagnóstico Precoz , Monitoreo Fisiológico/instrumentación , Marcapaso Artificial , Infarto del Miocardio con Elevación del ST/terapia , Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valor Predictivo de las Pruebas , Medición de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/mortalidad , Sensibilidad y Especificidad , Tasa de Supervivencia , Resultado del Tratamiento
6.
Proc (Bayl Univ Med Cent) ; 18(1): 74-5, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16200150
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA