Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros











Intervalo de año de publicación
1.
Mol Neurobiol ; 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39320565

RESUMEN

Numerous factors can contribute to the incidence or exacerbation of peripheral neuropathy induced by oxaliplatin (OXA). Recently, platinum accumulation in the spinal cord of mice after OXA exposure, despite the efficient defenses of the central nervous system, has been demonstrated by our research group, expanding the knowledge about its toxicity. One hypothesis is platinum accumulation in the spinal cord causes oxidative damage to neurons and impairs mitochondrial function. Thus, the main aim of this study was to investigate the relationship between aging and OXA-induced neuropathic pain and its comorbidities, including anxious behavior and cognitive impairment. By using an OXA-induced peripheral neuropathy model, platinum and bioelement concentrations and their influence on oxidative damage, neuroprotection, and neuroplasticity pathways were evaluated in Swiss mice, and our findings showed that treatment with OXA exacerbated pain and anxious behavior, albeit not age-induced cognitive impairment. Platinum deposition in the spinal cord and, for the first time, in the brain of mice exposed to OXA, regardless of age, was identified. We found that alterations in bioelement concentration, oxidative damage, neuroprotection, and neuroplasticity pathways induced by aging contribute to OXA-induced peripheral neuropathy. Our results strive to supply a basis for therapeutic interventions for OXA-induced peripheral neuropathy considering age specificities.

2.
ACS Chem Neurosci ; 15(21): 3954-3969, 2024 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-39207203

RESUMEN

This study aimed to elucidate vincristine (VCR)-induced peripheral neuropathy in aged rats, a poorly understood neurotoxicity. Both young and old Wistar rats were administered VCR (0.1 mg/kg, intraperitoneally (i.p.)) and compared to age-matched controls (0.9% saline; 10 mg/mL, i.p.). Mechanical (MN) and thermal nociceptive (TN) responses were assessed on days 0, 6, 11, and 17. Locomotor response, cognitive ability, and anxious-like behavior were evaluated on days 14, 15, and 16. Results showed MN and TN responses in both young and old VCR-exposed rats. In old rats, VCR exacerbated MN (on days 6, 11, and 17) and TN (on days 6 and 17) responses. VCR also induced cognitive impairments and anxiety-like behavior. Histological analysis revealed Wallerian degeneration in the spinal cords of VCR-exposed rats accompanied by macrophage migration. Furthermore, VCR increased Ca2+-ATPase activity while inhibiting Na+, K+-ATPase activity in young and old rats. VCR altered the homeostasis of Mg2+-ATPase activity. Lipid peroxidation and nitrite and nitrate levels increased in young and old rats exposed to VCR. This study provides valuable insights into VCR's mechanistic pathways in aged rats, emphasizing the need for further research in this area.


Asunto(s)
Adenosina Trifosfatasas , Envejecimiento , Estrés Oxidativo , Enfermedades del Sistema Nervioso Periférico , Ratas Wistar , Vincristina , Degeneración Walleriana , Animales , Vincristina/farmacología , Vincristina/toxicidad , Enfermedades del Sistema Nervioso Periférico/inducido químicamente , Enfermedades del Sistema Nervioso Periférico/patología , Enfermedades del Sistema Nervioso Periférico/metabolismo , Estrés Oxidativo/efectos de los fármacos , Ratas , Degeneración Walleriana/inducido químicamente , Degeneración Walleriana/patología , Degeneración Walleriana/metabolismo , Masculino , Envejecimiento/efectos de los fármacos , Adenosina Trifosfatasas/metabolismo , Peroxidación de Lípido/efectos de los fármacos , Antineoplásicos Fitogénicos/farmacología , Médula Espinal/efectos de los fármacos , Médula Espinal/metabolismo , Médula Espinal/patología , ATPasa Intercambiadora de Sodio-Potasio/metabolismo
3.
Anal Bioanal Chem ; 416(11): 2859-2870, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38459967

RESUMEN

Microwave-induced combustion (MIC) was proposed in this study for honey decomposition aiming for As, Cd, Hg, and Pb determination by inductively coupled plasma mass spectrometry (ICP-MS). Sample mass (up to 1.0 g), absorbing solution (0.5 to 14.4 mol L-1 HNO3, and H2O), heating program, and combustion aids were evaluated. The Eurachem guidelines were used for method validation. The proposed method enabled combustion of a high sample mass (0.8 g of honey, with 0.4 g of microcrystalline cellulose and 100 µL of 6 mol L-1 NH4NO3) using 6 mL of an absorbing solution consisting of 1 mol L-1 HNO3, which resulted in low residual carbon in solution (< 25 mg L-1). Honey samples from different geographical origins were analyzed. Results showed no significant difference in comparison to other two microwave decomposition methods, based on microwave-assisted wet digestion with single reaction chamber (MAWD-SRC) and microwave-assisted wet digestion (MAWD). Standard addition experiments resulted in recoveries higher than 98%. The limits of detection ranged from 1.10 (As) to 4.60 ng g-1 (Pb). In addition to using only diluted reagents and resulting in digests virtually free of interferences, the proposed method was faster (< 30 min) than most of those presented in the literature.


Asunto(s)
Miel , Microondas , Espectrometría de Masas/métodos , Plomo , Análisis Espectral
4.
Ultrason Sonochem ; 103: 106788, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309048

RESUMEN

In this study, ultrasound (US) was evaluated for As, Cd, Pb, Mn, Sr and V extraction from seaweed samples. The following parameters of ultrasound-assisted extraction (UAE) using an US bath were: frequency (25 to 130 kHz), amplitude (30 to 100%), temperature (30 to 80 °C), sample mass (50 to 200 mg), extractant concentration (1 to 3 mol L-1 of HNO3) and treatment time (5 to 30 min). Acoustic density and power density distribution were calculated using the calorimetric method and mapping of the acoustic pressure distribution was also evaluated. The optimized UAE conditions were 200 mg of sample in 10 mL of 2 mol L-1 HNO3 and 30 min of sonication in a 25 kHz US bath (37.2 ± 4.0 W L-1) at 70% of amplitude and 70 °C. Analytes were quantified using inductively coupled plasma mass spectrometry and results were compared with values obtained using "silent" conditions (magnetic or mechanical stirring at 500 rpm, and without stirring), and a reference method based on microwave-assisted wet digestion (MAWD). The UAE method demonstrated the best extraction efficiency (higher than 95%) for all analytes, especially for As, Cd and V, with lower standard deviations (up to 5%) and lower blank values in comparison with the silent conditions. The proposed UAE method was more advantageous than the reference method, being faster, simpler, safer, more environmentally friendly, and with higher detectability (lower limits of quantification, from 0.0033 to 1.34 µg g-1). In addition, negligible blank values were obtained for UAE and no interference were observed in the determination step. Furthermore, the optimized UAE method was applied for Antarctic seaweed samples and comparison with results obtained by MAWD was satisfactory. In this sense, UAE is demonstrated to be a suitable option for sample preparation of seaweed samples and further determination of environmentally critical elements avoiding the use of concentrated reagents as in the MAWD reference method.


Asunto(s)
Algas Marinas , Espectrometría de Masas/métodos , Cadmio , Análisis Espectral/métodos , Verduras
5.
J Agric Food Chem ; 2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-36972393

RESUMEN

A strategy for determining the bioaccessibility of bromine and iodine from edible seaweeds was proposed for the first time using microwave-induced combustion (MIC) and ion chromatography coupled to mass spectrometry (IC-MS) after in vitro digestion. The concentrations of bromine and iodine in edible seaweeds using the proposed methods (MIC and IC-MS) were not statistically different from those using MIC and inductively coupled plasma mass spectrometry (p > 0.05). Trueness was assessed by recovery experiments (101-110%, relative standard deviation <10%). Following an in vitro digestion protocol, MIC was proposed as sample preparation for bioaccessible and residual fractions. Using this strategy, the mass balance totaled from 97 to 111%. No statistical difference (p > 0.05) was observed between the total concentration of bromine or iodine and their concentration in bioaccessible and residual fractions for three edible seaweed species, indicating full analyte quantification in the fractions.

6.
Anal Chim Acta ; 1199: 339569, 2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35227390

RESUMEN

In this work, high purity graphite, a high chemically stable material, was effectively digested using a single method allowing compatible solutions for the further multitechnique determination of halogens by: ion chromatography (F and Cl), inductively coupled plasma mass spectrometry (Cl, Br and I) and by ion selective electrode (only for F). The recent system using microwave-induced self-ignition (MISI) is based on the strong interaction between microwave radiation and graphite in a closed system pressurized with oxygen (Maxwell-Wagner effect). Carbon-based materials present intense and specific interfacial polarization when exposed to microwave electromagnetic field resulting in a fast heating rate. This effect associated to a pressurized oxygen system, provides a quick self-ignition of carbon-based materials and consequent combustion/digestion of organic matrices. Under optimized conditions, sample masses up to 600 mg were fully digested in a quartz vessel under 20 bar of oxygen pressure and using just a diluted solution (100 mmol L-1 NH4OH) for the quantitative absorption of all the analytes. MISI method was validated, and the accuracy (better than 94%) was evaluated by comparison of results obtained by pyrohydrolysis for two coal certified reference materials as well as with subsequent analytes determination by the three techniques: IC, ICP-MS and ISE. It is important to point out that no filter paper disks, electrical connections or other ignition aids are required as in the case of previous or classical combustion methods. Moreover, just a diluted absorbing solution was used resulting in negligible blanks and relatively low limits of detection. The digestion efficiency was higher than 99%, making the proposed method a suitable and powerful alternative for the quasi complete digestion of graphite and determination of halogens virtually free of interferences.


Asunto(s)
Grafito , Halógenos , Digestión , Halógenos/análisis , Espectrometría de Masas/métodos , Microondas
7.
Ultrason Sonochem ; 72: 105453, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33412386

RESUMEN

Nitrocellulose is a nitrated cellulose polymer with a broad application in industry. Depending on the nitrogen content, this polymer can be used for manufacturing explosives, varnishes, clothes, and films, being considered a product of high value-added. In this work, the use of ultrasound was investigated for the intensification of nitrocellulose synthesis from microcrystalline cellulose. The ultrasound-assisted nitrocellulose synthesis (UANS) was carried out using several ultrasound systems, such as baths and cup horns, allowing the evaluation of the frequency (from 20 to 130 kHz) and delivered power (from 23 to 134 W dm-3) to the reaction medium. The following parameters were evaluated: acid mixture (H2SO4, H3PO4, CH2O2 or CH3COOH with HNO3, 2 to 14.4 mol L-1), ultrasound amplitude (10 to 70%) and reaction time (5 to 50 min). Better nitrocellulose yield (nitrogen content of 12.5% was obtained from 1 g of microcrystalline cellulose employing a cup horn system operating at 20 kHz, 750 W of nominal power with 60% of amplitude, 25 mL of acid solution (13.6 mL of 18.4 mol L-1 H2SO4 + 9.2 mL of 14.4 mol L-1 HNO3 + 2.2 mL H2O), at 30 °C for 30 min. At silent conditions (mechanical stirring ranging from 100 to 500 rpm), the nitrogen content was lower than 11.8% which demonstrate the ultrasound effects for nitrocellulose synthesis.

8.
Food Chem ; 344: 128671, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-33261997

RESUMEN

Direct analysis of flour was proposed for the determination of Cl and S by an elemental analyzer for the first time. The main operational conditions of the direct solid sampling elemental analysis (DSS-EA) were optimized and calibrated by standard solutions, rather than by certified reference material (CRM). Accuracy was evaluated by the analysis of CRM of rice flour and by comparison with analyte determination by independent techniques, i.e., ion chromatography and inductively coupled plasma optical emission spectrometry; both were carried out after microwave-induced combustion. Sample mass from 0.5 to 260 mg was used and limits of quantification of 1.2 µg g-1 for Cl and 0.2 µg g-1 for S were achieved. Wheat, whole wheat, potato and corn flour were analyzed by DSS-EA. Concentrations of Cl and S ranged from 4.8 to 685 µg g-1 and from 13 to 1328 µg g-1, respectively.


Asunto(s)
Cloro/análisis , Harina/análisis , Análisis de los Alimentos/métodos , Azufre/análisis , Calibración , Microondas , Oryza/química , Triticum/química
9.
Mol Neurobiol ; 57(12): 5219-5234, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32869182

RESUMEN

In this study, the deposition of platinum in oxaliplatin (OXA)-exposed mice and the effects of the oxidative damage on the central nervous system were investigated. The relationship between the reactive species (RS) levels as well as the expression and activity of enzymes, such as catalase (CAT), glutathione peroxidase (GPx), superoxide dismutase (SOD) and acetylcholinesterase (AChE), in the development of peripheral neuropathy after OXA exposure, was evidenced. The effects of 7-chloro-4-(phenylselanyl) quinoline (4-PSQ) on OXA-induced peripheral neuropathy was also investigated. Swiss mice received OXA (10 mg kg-1) or vehicle by intraperitoneal route (days 0 and 2). Oral administration of 4-PSQ (1 mg kg-1) or vehicle was performed on days 2 to 14. Behavioural tasks started on day 9, after the first OXA administration. It was observed that 4-PSQ reduced the mechanical and thermal hypersensitivity induced by OXA. 4-PSQ and OXA did not affect locomotor and exploratory activities. The results revealed, for the first time, a high concentration of platinum in the spinal cord of mice exposed to OXA. 4-PSQ reversed the increased levels of RS in the spinal cord, cerebral cortex and hippocampus of mice exposed to OXA. The alterations in the activity and expression of the GPx, SOD, CAT and AChE induced by OXA exposure were normalized by 4-PSQ. Therefore, the 4-PSQ might be a good prototype for the development of a more effective drug for the treatment of OXA-induced peripheral neuropathy. The results obtained by the present study expanded the knowledge about the mechanisms involved in the physiopathology of peripheral neuropathy. Graphical abstract.


Asunto(s)
Oxaliplatino/efectos adversos , Enfermedades del Sistema Nervioso Periférico/inducido químicamente , Enfermedades del Sistema Nervioso Periférico/tratamiento farmacológico , Quinolinas/uso terapéutico , Acetilcolinesterasa/metabolismo , Animales , Antioxidantes/farmacología , Catalasa/metabolismo , Conducta Exploratoria/efectos de los fármacos , Glutatión Peroxidasa/metabolismo , Masculino , Ratones , Actividad Motora/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Quinolinas/farmacología , Reproducibilidad de los Resultados , Médula Espinal/efectos de los fármacos , Médula Espinal/enzimología , Médula Espinal/patología , Superóxido Dismutasa/metabolismo , Temperatura
10.
Anal Bioanal Chem ; 412(24): 6475-6484, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32394040

RESUMEN

The halogen determination is important in view of their biological and environmental roles, but their determination has still been considered a challenge, especially at low concentrations. Therefore, a method for honey decomposition using microwave-induced combustion (MIC) combined with ion chromatography and conductimetric detection (for Cl, F, and S determination) or mass detection (for Br and I determination) (IC-CD-MS) is proposed. Trueness was evaluated by adding reference materials (RMs) or a standard solution in the sample. By using 50 mmol L-1 NH4OH as the absorbing solution, recoveries for all analytes were between 94 and 103%, in both tests. Moreover, no statistical difference (t test, confidence level of 95%) was observed for the results obtained by IC in comparison with those obtained by inductively coupled plasma optical emission spectroscopy (Cl and S) and by inductively coupled plasma mass spectrometry (Br and I). Finally, the proposed method was applied to 19 honey samples from different origins. The concentrations ranged from < 0.45 to 2.39 mg kg-1 (Br), 21.8 to 671 mg kg-1 (Cl), and 11 to 154 mg kg-1 (S), while the F and I concentrations were below that their quantification limits (LOQs) in all analyzed samples. The LOQs for Br, Cl, F, I, and S were 0.45, 21, 3.7, 0.077, and 8.7 mg kg-1, respectively. The MIC method provided a compatible solution to IC for the halogen and S determination in honey by a single analysis. Graphical abstract.


Asunto(s)
Análisis de los Alimentos/métodos , Halógenos/análisis , Miel/análisis , Azufre/análisis , Límite de Detección , Espectrometría de Masas/métodos , Microondas
11.
Environ Sci Pollut Res Int ; 27(17): 21914-21923, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32285391

RESUMEN

In this work, some trace elements (As, Cd, Cr, Cu, and Pb) were determined for the first time in the crustacean Sergio mirim (Decapoda: Thalassinidea: Callianassidae) from Southern Coast (Rio Grande, RS) of Brazil. The trace element determination was carried out by graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma mass spectrometry (ICP-MS). Different microwave radiation-based sample digestion methods were evaluated. The analyte concentration ranged from 1.45 to 3.70 µg g-1 for As, 0.615 to 0.942 µg g-1 for Cd, 0.884 to 7.20 µg g-1 for Cr, 122 to 275 µg g-1 for Cu, and 0.390 to 0.916 µg g-1 for Pb. The limits of quantification for As, Cd, Cr, Cu, and Pb were 0.12, 0.01, 0.16, 0.92, and 0.06 µg g-1, respectively. The accuracy was evaluated by results comparison between GF AAS and ICP-MS techniques, as well as by analysis of certified reference materials of fish muscle and oyster tissue, with agreement from 92 to 108%. The feasibility of using Sergio mirim as a promising environmental bioindicator candidate was evaluated, since that it is an abundant organism in the studied area (South cost of Brazil) as well as in other places around the world.


Asunto(s)
Decápodos , Oligoelementos/análisis , Animales , Brasil , Alimentos Marinos/análisis , Espectrofotometría Atómica
12.
Food Chem ; 321: 126715, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32259733

RESUMEN

Sample preparation methodsforcereal digestion were evaluated for the first time for subsequent As, Cd, Hg, and Pb determination by atomic absorption spectroscopy techniques. Microwave-assisted digestion (MW-AD) under high and medium pressure and microwave-induced combustion (MIC) were evaluated. The use of MIC made it possible to digest 700 mg of samples, and agreements of 97, 96, 100 and 92% were obtained for As, Cd, Hg and Pb, respectively, when 7 mol L-1 HNO3 was used as the absorbing solution. It was not necessary to dilute the digests obtained to avoid interferences in the quantification of As, Cd, Hg, and Pb. Although high pressure MW-AD was efficient for cereal digestion, interferences were observed on analyte determination. Limits of quantification obtained by MIC were 0.034 (As), 0.015 (Cd), 0.021 (Hg) and 0.105 (Pb) µg g-1, which are suitable to attain the maximum levels recommended by international agencies in cereal samples.


Asunto(s)
Arsénico/análisis , Cadmio/análisis , Grano Comestible/química , Plomo/análisis , Mercurio/análisis , Microondas , Espectrofotometría Atómica
13.
Food Chem ; 285: 334-339, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30797354

RESUMEN

A versatile, rapid and safe green method for chlorine and sulfur determination using ion chromatography in cereals and legumes was developed. Microwave-induced combustion was evaluated for sample preparation. Ultrapure water and alkaline solutions were assessed for absorption of the analytes. Water was selected because good recoveries (97-109%) were obtained for both analytes. Low consumption of reagents and small quantities of waste are two important advantages of the proposed method. Accuracy was evaluated by analysis of a standard reference material, which agreed with certified values (91-101%). The results for repeatability (RSDs ≤ 4%) and intermediate precision (RSDs ≤ 7%) prove the good precision of the proposed method. Limits of quantification were 16 and 17 mg kg-1 for Cl and S, respectively. Concentrations of Cl and S varied across a wide range (Cl: 35-930 mg kg-1; S: 678-5124 mg kg-1) for 34 samples analyzed, which were, for most of the results, close to the values found in the literature.


Asunto(s)
Cloro/análisis , Grano Comestible/química , Fabaceae/química , Análisis de los Alimentos/métodos , Azufre/análisis , Cromatografía por Intercambio Iónico/métodos , Cromatografía por Intercambio Iónico/normas , Harina/análisis , Análisis de los Alimentos/normas , Límite de Detección , Microondas , Estándares de Referencia , Agua/química
14.
Talanta ; 181: 440-447, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29426538

RESUMEN

In this work a feasible method for chloride and sulfate determination in calcium carbonate pharmaceutical raw material and commercial tablets by ion chromatography after microwave-induced combustion was developed. The analytes were released from matrix by combustion in closed system pressurized with oxygen. Starch as volatilization aid, 100mmolL-1 HNO3 as absorbing solution and 5min of microwave irradiation time were used. Recovery tests using standard solutions were performed for the accuracy evaluation. A mixture of calcium carbonate pharmaceutical raw material or commercial tablets, starch and a certified reference material was also used as a type of recovery test. Recoveries ranging from 88% to 103% were obtained in both spike tests. Limits of detection (Cl-: 40µgg-1 and SO42-: 140µgg-1) were up to eighteen times lower than the maximum limits established for the analytes by Brazilian, British, European and Indian Pharmacopoeias. The limit tests recommended by the European Pharmacopoeia for Cl- and SO42- in CaCO3 were carried out to compare the results. Chloride and SO42- concentrations in the samples analyzed by proposed method were in agreement with those results obtained using the tests recommended by the European Pharmacopoeia. However, the proposed method presents several advantages for the routine analysis when compared to pharmacopoeial methods, such as the quantitative simultaneous determination, high sample preparation throughput (up to eight samples per run in less than 30min), reduced volume of reagents and waste generation. Thus, the proposed method is indicated as an excellent alternative for Cl- and SO42- determination in CaCO3 pharmaceutical raw material and commercial tablets.


Asunto(s)
Carbonato de Calcio/química , Cloruros/análisis , Sulfatos/análisis , Comprimidos/química , Métodos Analíticos de la Preparación de la Muestra/instrumentación , Métodos Analíticos de la Preparación de la Muestra/métodos , Contaminación de Medicamentos/prevención & control , Microondas , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Volatilización
15.
Food Chem ; 246: 422-427, 2018 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-29291868

RESUMEN

An eco-friendly method for indirect determining phosphorus and sulfur in animal feed by ion chromatography was proposed. Using this method, it was possible to digest 500 mg of animal feed in a microwave system under oxygen pressure (20 bar) using only a diluted acid solution (2 mol L-1 HNO3). The accuracy of the proposed method was evaluated by recovery tests, by analysis of reference material (RM) and by comparison of the results with those obtained using conventional microwave-assisted digestion. Moreover, P results were compared with those obtained from the method recommended by AOAC International for animal feed (Method nr. 965.17) and no significant differences were found between the results. Recoveries for P and S were between 94 and 97%, and agreements with the reference values of RM were better than 94%. Phosphorus and S concentrations in animal feeds ranged from 10,026 to 28,357 mg kg-1 and 2259 to 4601 mg kg-1, respectively.


Asunto(s)
Alimentación Animal/análisis , Cromatografía Liquida/métodos , Fósforo/análisis , Azufre/análisis , Animales , Digestión , Microondas , Ácido Nítrico/química , Oxígeno/química
16.
Ultrason Sonochem ; 40(Pt B): 53-59, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28433504

RESUMEN

Water removal is an essential step during crude oil production due to several problems such as increased transportation costs and high corrosion rate due to dissolved salts. Indirect low frequency ultrasonic energy (US), using baths, has been recently proposed as an effective alternative for crude oil demulsification. However, the reactor position during sonication and its influence on the demulsification efficiency for crude oil has not been evaluated. In this sense, the aim of this study was to develop an automated system based on an open source hardware for mapping the acoustic field distribution in an US bath operating at 35kHz using a hydrophone. Data acquired with this system provided information to evaluate the demulsification efficiency in the different positions of the US bath and correlate it with the acoustic intensity distribution. The automated 3D-mapping system revealed a higher acoustic intensity in the regions immediately above the transducers (ca. 0.6Wcm-2), while the other regions presented a relatively lower intensity (ca. 0.1Wcm-2). Experimental data demonstrated that reactors positioned in the most intense acoustic regions provided a much higher efficiency of demulsification in comparison with the ones positioned in the less intense acoustic field regions. Demulsification efficiency up to 93% was obtained with 15min of sonication (100% amplitude) using few amount of chemical demulsifier. Hence, this work demonstrated that the information acquired with the developed mapping system could be used for inducing a higher efficiency of demulsification only by finding the more suitable position of reactor in the US bath, which certainly will help development of appropriate reactors design when looking for such approach.

17.
Anal Bioanal Chem ; 408(17): 4547-66, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27020927

RESUMEN

Interest in the determination of elemental impurities in pharmaceuticals has increased in recent years because of changes in regulatory requirements and the need for changing or updating the current limit tests recommended in pharmacopeias. Inductively coupled plasma (ICP) optical emission spectrometry and ICP mass spectrometry are suitable alternatives to perform multielemental analysis for this purpose. The main advantages and limitations of these techniques are described, covering the applications reported in the literature in the last 10 years mainly for active pharmaceutical ingredients, raw materials, and pharmaceutical dosage forms. Strategies used for sample preparation, including dissolution in aqueous or organic solvents, extraction, wet digestion and combustion methods are described, as well as direct solid analysis and ICP-based systems applied for speciation analysis. Interferences observed during the analysis of pharmaceutical products using ICP-based methods are discussed. Methods currently recommended by pharmacopeias for elemental impurities are also covered, showing that the use of ICP-based methods could be considered as a trend in the determination of these impurities in pharmaceuticals. However, the development of a general method that is accurate for all elemental impurities and the establishment of an official method are still challenges. In this regard, the main drawbacks and suitable alternatives are discussed.


Asunto(s)
Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/química
18.
J Agric Food Chem ; 64(8): 1817-22, 2016 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-26829049

RESUMEN

The concentration of bromine and iodine was determined in shrimp and its parts (tissue and shells), and changes in the analyte concentration were evaluated after the cooking procedure. Bromine and iodine concentrations were determined by a method recently developed by our research group based on microwave-induced combustion for sample preparation and inductively coupled plasma mass spectrometry for analyte determination. The accuracy was evaluated using a reference material (NIST 8414) that was digested using the proposed method. No statistical difference was observed between certified and determined values (Student's t test, 95% confidence level). Suitable limits of detection (Br, 0.02 µg g(-1) and I, 0.01 µg g(-1)) were obtained for both analytes. Higher concentrations of both analytes were observed in shrimp shells in comparison to shrimp tissue for raw and cooked samples. Moreover, losses of Br and I (between 24 and 43%) were observed after cooking.


Asunto(s)
Bromo/análisis , Crustáceos/química , Yodo/análisis , Mariscos/análisis , Exoesqueleto/química , Animales , Culinaria , Espectrometría de Masas
19.
Talanta ; 147: 76-81, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26592579

RESUMEN

A microwave-induced combustion (MIC) system based on the volatilization process was applied for subsequent halogen determination from noncombustible inorganic matrices. Portland cement samples were selected to demonstrate the feasibility of the proposed method, allowing the subsequent determination of Cl and F by ion chromatography (IC). Samples were mixed with high-purity microcrystalline cellulose, wrapped with a polyethylene film and combusted in quartz closed vessels pressurized with oxygen (20bar). Water and NH4OH (10, 25 or 50m mol L(-1)) were evaluated for Cl and F absorption, but water was selected, using 5min of reflux after volatilization. Final solutions were also suitable for analysis by pontentiometry with ion-selective electrode (ISE) for both analytes, and no difference was found when comparing the results with IC. The accuracy of the proposed method for Cl was evaluated by analysis of certified reference materials (CRMs), and agreement with certified values ranged from 98% to 103%. Results were also compared to those using the procedure recommended by the American Society of Testing and Materials (ASTM) for the determination of total chlorides (C114-13), and no difference was found. Volatilization by MIC using a mixture of cement, cellulose and a biological CRM was carried out in order to evaluate the accuracy for F, and recovery was about 96%. The proposed method allowed suitable limits of detection for Cl and F by IC (99 and 18mg kg(-1), respectively) for routine analysis of cement. Using the proposed method, a relatively low standard deviation (<7%), high throughput (up to eight samples can be processed in less than 30min) and lower generation of laboratory effluents, when compared to the ASTM method, were obtained. Therefore, the method for volatilization of Cl and F by MIC and subsequent determination by IC can be proposed as a suitable alternative for cement analysis.

20.
Anal Bioanal Chem ; 407(26): 7957-64, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26310846

RESUMEN

This work demonstrates the feasibility of ultra-trace determination of halogens in biological samples by inductively coupled plasma mass spectrometry (ICP-MS) after decomposition by microwave-induced combustion (MIC). The conventional MIC method was improved to allow the combustion of samples with mass higher than that used in previous works in order to achieve better limits of detection (LODs). The applicability of the proposed method for ultra-trace determination of bromine and iodine in organic samples was demonstrated here using honey. It was possible to decompose up to 1000 mg of honey using microcrystalline cellulose as a combustion aid and polyethylene film for sample wrapping. After combustion, analytes were absorbed using 50 mmol L(-1) NH4OH and recoveries for Br and I were between 99 and 104 %, and relative standard deviations were lower than 5 %. Microwave-assisted alkaline dissolution (MA-AD) was also evaluated for honey sample preparation using NH4OH or tetramethylammonium hydroxide solutions. However, the LODs for the MA-AD method were unsuitable because the high carbon content in digests required a dilution step prior to the analysis by ICP-MS. The LODs obtained by MIC were improved from 1143 to 34 ng g(-1) for Br and from 571 to 6.0 ng g(-1) for I, when compared to the MA-AD method. Furthermore, it was possible to decompose up to eight samples simultaneously in 30 min (including the cooling step) with very low reagent consumption and consequently lower generation of effluents, making MIC method well suited for routine ultra-trace determination of Br and I in honey. Graphical Abstract A high mass of honey was efficiently digested by MIC for subsequent Br and I determination by ICP-MS.


Asunto(s)
Bromo/análisis , Miel/análisis , Yodo/análisis , Espectrometría de Masas/métodos , Microondas , Celulosa/química , Diseño de Equipo , Estudios de Factibilidad , Calor , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA