RESUMEN
Objectives: This study aimed to establish a single-session associative protocol for non-restorative management of dentin hypersensitivity (DH). Materials and Methods: Twenty-four individuals with DH and a minimum sensitivity level of 4 on the visual analog scale (VAS) were selected. The study was conducted in a split-mouth design, with each participant (n = 20) having at least 1 affected tooth in all quadrants. The management protocols consisted of control group: universal adhesive, Neural Desensitizing Protocol group: 5% potassium nitrate, Mixed Desensitizing Protocol (PAM) group: 5% sodium fluoride and 5% potassium nitrate, Remineralizing Desensitizing Protocol (PDR) group: surface-partially reacted glass technology photopolymerizable varnish. Evaluations were performed immediately after application, at 1 week, 1 month, 2 months, and 12 months using the VAS sensitivity test. Results: The scores were subjected to statistical analysis using the Friedman test (p < 0.05), Durbin-Conover test (p < 0.05), and Wilcoxon test (p < 0.05). At the 12-month evaluation, all groups showed statistically significant differences compared to the initial assessment. For the evaluation after 12 months, there was a statistically significant difference between the PAM group, the control group, and the PDR group. Conclusions: It can be concluded that all groups were effective in controlling DH, but there were significant results in the control group and PDR group. The clinical relevance of this study is to demonstrate that the application of single-session desensitizing protocols can be effective in controlling DH for up to 12 months. Trial Registration: Brazilian Clinical Trials Registry Identifier: RBR-4r63d7s.
RESUMEN
OBJECTIVES: This study evaluated the linear dimensional change of polymerization of three materials and two techniques of the union of molding transfers for implant-supported prostheses used in the open-tray technique. MATERIALS AND METHODS: A nylon maxilla-shaped matrix was made, two osseous integrated implants were installed, and, over these two, straight conical mini-pillars were installed. Open-tray impression transfers were attached to the mini-pillars, and a silicone guide was made to standardize the connections between the transfers. The samples were divided into six groups (n = 20): PA (Pattern Resin LS, chemically activated acrylic resin in the single step technique); DU (Durallay, chemically activated acrylic resin in the single step technique); BI (Protemp4, bisacrylic resin in the single step technique); PAC (Pattern Resin LS in sectioning and joining of segments technique); DUC (Durallay, in sectioning and joining of segments technique); and BIC (Protemp4, in sectioning and joining of segments technique). The linear dimensional change values that occurred among these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check device, with a resolution of 0.001 mm, performed by a single calibrated operator. STATISTICAL ANALYSIS: Data were submitted to a two-way analysis of variance and Tukey's test (p < 0.01). RESULTS: Statistically significant mean values were found in all comparisons. The PA showed the lowest mean values (µm) of linear dimensional change, both in the single-step technique and in the sectioning and joining technique, in the following order: BI 255.73 (3.81), DU 173.75 (2.30), PA 95.97 (3.20), BIC 23.82 (1.71), DUC 20.85 (2.53), and PAC 13.27 (2.09). The single-step technique showed the worst results, regardless of the material. CONCLUSION: The sectioning and joining technique reduced the dimensional change in all materials, and the Pattern Resin LS showed the lowest shrinkage mean values, followed by Durallay and Protemp4.
RESUMEN
OBJECTIVE: To evaluate and compare the friction of different ligature modes used in orthodontics, and to propose a new ligature model for conventional brackets ("H low-friction orthodontic ligature). MATERIALS AND METHODS: Samples were randomly divided into seven experimental groups: (1) resin H ligature (H3D), designed by the authors of this study and produced in a 3D printer, with conventional bracket; (2) metal H ligature (HFM), with conventional bracket; (3) passive self-ligating bracket (SLP); (4) "8" low-friction unconventional elastic (LT8), with conventional bracket; (5) loose conventional metal ligature (MLS), with conventional bracket; (6) conventional metal ligature fully tightened (MLT), with conventional bracket; (7) conventional elastic ligature (CEL), with conventional bracket-control. All samples were subjected to mechanical static friction testing using the EMIC DL 2000 universal testing machine. STATISTICAL ANALYSIS: To assess the normality requirement, the Shapiro-Wilk test was used, which showed a non-normal distribution for the means of the groups (p < 0.05). Therefore, statistical tests were performed to assess the existence of statistically significant differences between the groups through the Kruskal-Wallis, followed by Dunn's test, pairwise comparison, p < 0.05. RESULTS: The results obtained showed lower friction values for HFM (0.002 kgf), SLP (0.003 kgf), and LT8 (0.004 kgf)-these did not differ statistically from each other. These were followed by H3D (0.020 kgf), MLS (0.049 kgf), CEL (0.12 kgf), and, finally, MLT (0.21 kgf). CONCLUSION: The lowest friction value was found for the metal H ligature, similar to the self-ligating bracket and the "8" low-friction unconventional elastic. The resin H ligature presented intermediate friction values and the highest friction force was found for the MLT group.
RESUMEN
This study evaluated the effect of auricular acupuncture (AA) on physical (PA) and emotional (EA) aspects of patients with temporomandibular disorders (TMDs) and compared the effect of AA with those of Sham and occlusal splints (OS). In accordance with the CONSORT guidelines, patients with TMDs were evaluated by axes I and II of the RDC-TMD. The patients were allocated among three groups: OS, Sham and AA; and followed for 8 weeks. Both intragroup and intergroup evaluation for quantitative variables were analyzed with ANOVA, one-way, followed by the Tukey test. Qualitative variables were analyzed with the Kruskal-Wallis, and Dunn tests (intergroup evaluation) and for intragroup analyses, the Friedman and Wilcoxon tests were applied. At the end of the experiment, the chi-squared test was applied to compare the three groups with respect to the number of variables that had shown improved scores. The adopted level of significance for all tests was α = 5%. Intragroup analysis showed that, in the Sham group, no improvement in performance was seen in either EA and significant was improvements in 5 variables for 9 for PA, while in the AA group, significant improvements were observed in 2 variables for EA and in 9 for PA. In the OS group at the end of this study, significant improvements were observed in 8 and 8 variables for EA and PA, respectively. The analysis of therapies used revealed that the number of variables exhibiting significantly improved outcomes after treatment was similar between the AA and OS groups, whereas the sham group showed statistically significant differences when compared with the other two groups. In conclusion, this study demonstrated that AA applied at a specific TMJ ear point was able to bring about improvements in patients with TMDs, with outcomes similar to those in patients treated with an OS. CLINICAL TRIAL REGISTRATION: RBR-69ynnw (Brazilian Registry of Clinical Trials).
Asunto(s)
Acupuntura Auricular , Ferulas Oclusales , Trastornos de la Articulación Temporomandibular , Acupuntura Auricular/métodos , Brasil , Humanos , Trastornos de la Articulación Temporomandibular/etiología , Trastornos de la Articulación Temporomandibular/psicología , Trastornos de la Articulación Temporomandibular/terapia , Resultado del TratamientoRESUMEN
The aim of this study was to evaluate the effect of different commercial silanes on microshear bond strength of resin cement to lithium disilicate ceramic. Twenty ceramic samples with 10 mm in length, 10 mm wide and 3 mm in thickness were fabricated, etched with 10% hydrofluoric acid for 20 seconds, and divided into 5 groups, according to the commercial silane applied: G1- RelyX Ceramic Primer (3M ESPE), G2- Angelus Silane, G3- Prosil (FGM), G4- Dentsply Silane (Dentsply) and G5- Bis-Silane (Bisco). Silanes were applied in accordance to manufacturers' recommendations. Addition silicone molds with 1 mm in thickness, 10 mm in diameter and 3 perforations with 1 mm in diameter each one, were placed on ceramic and filled with the resin cement RelyX ARC (3M ESPE) in all groups. Light activation was performed with LED Bluephase G2 (Ivoclar Vivadent) at 1200 mW/cm2, for 30 seconds. Samples were maintained in 100% humidity at 37°C for 24 hours and submitted to microshear test. The data (MPa) were submitted to one-way ANOVA and Tukey test (α=0.05). The results obtained for each group were: G1: 22.39±2.99; G2: 23.35±4.08; G3: 26.05±5.46; G4: 18.56±4.09; G5: 25.26±4.10. Statistical analysis showed significantly lower microshear bond strength for G4. Fracture pattern analysis showed predominance of adhesive failures in G1 and G2. G3 and G5 presented higher percentage of cohesive failures in ceramic, and G4 showed mixed, adhesive and cohesive fractures with similar percentages. It was concluded that different silanes showed influence on the lithium disilicate ceramic resin cement bond strength
O objetivo neste estudo foi avaliar o efeito de diferentes silanos comerciais na resistência de união ao microcisalhamento do cimento resinoso à cerâmica de dissilicato de lítio. Foram confeccionadas 20 amostras de cerâmica (10mm de comprimento, 10mm de largura e 3mm de espessura), condicionadas com ácido fluorídrico a 10% por 20 segundos e divididas em 5 grupos, de acordo com o silano aplicado: G1- RelyX Ceramic Primer (3M ESPE), G2- Silano Angelus, G3-Prosil (FGM), G4- Silano Dentsply e G5-Bis-Silane (Bisco). Matrizes de silicone por adição (1 mm de espessura, 10 mm de diâmetro e 3 perfurações com 1 mm de diâmetro) foram colocadas sobre a cerâmica e preenchidas com cimento resinoso RelyX ARC (3M ESPE). A fotoativação foi realizada com LED Bluephase G2 (Ivoclar Vivadent) a 1200 mW/cm2, por 30 segundos. As amostras foram mantidas em 100% de umidade a 37°C por 24 horas e submetidas ao teste de microcisalhamento. Os dados (MPa) (G1: 22,39+2,99; G2: 23,35+4,08; G3: 26,05+5,46; G4: 18,56+ 4,09; G5: 25,26+4,10) foram submetidos a análise de variância e ao teste de Tukey (p<0,05). A análise estatística mostrou valor de resistência de união significantemente menor para G4. A análise do padrão de fratura mostrou predominância de falha adesiva para G1 e G2. G3 e G5 apresentaram maior porcentagem de falha coesiva em cerâmica, e o G4 apresentou fraturas mista, adesiva e coesiva em igual porcentagem. Concluiu-se que os diferentes silanos apresentaram influência na resistência de união do cimento resinoso à cerâmica de dissilicato de lítio
Asunto(s)
Silanos , Cerámica , Cementos Dentales , Resistencia al Corte , Litio , Cemento de Silicato , Cementación , Cementos de Resina , Porcelana DentalRESUMEN
OBJECTIVE: This study evaluates the bond strength of two compositions of aesthetic translucent zirconia (TZ). MATERIALS AND METHODS: For this evaluation, test specimens were prepared from ICE Zirkon TZ and Prettau Anterior zirconia (PAZ) that were stored in distilled water at 37°C for two time periods: T1 (24 h) and T2 (90 days) to simulate aging. Two factors were evaluated for the samples-ceramic and aging time. The samples were subjected to tests of microshear strength and fracture type and were evaluated using scanning electron microscopy. RESULTS: The results were analyzed using the D'Agostino test, analysis of variance, and Tukey's test (p < 0.01). Statistically significant differences were observed for ceramic type and aging time. CONCLUSION: The results showed that PAZ provides significantly superior performance to TZ at the two aging times evaluated.
RESUMEN
The aim of this study was to use the isobornyl methacrylate (IBOMA) as a combining or substituent diluent monomer in the resin matrix of dental resin composites. Thus, the resin matrix was formulated with 60 wt% of BisGMA and 40 wt% of diluent monomers. TEGDMA as the only diluent monomer was used as control with 40 wt%, while total substitution of TEGDMA was done with 40 wt% of IBOMA. The combination of IBOMA and TEGDMA was done with 20 wt% of each monomer. To the resin matrix, 65 wt% of filler particles was added. Degree of conversion (DC) using FT-IR, flexural strength (FS), flexural modulus (FM), polymerization shrinkage by gap formation (GF), Knoop hardness (KH) and solvent degradation (SD) were evaluated. Data were analyzed using ANOVA and Tukey's test (α=0.05; b=0.2). The results showed that reducing or substituting TEGDMA using IBOMA did not affect the DC (0.085), FS (p=0.886) or FM (p=0.414). Also, when IBOMA was used, lower GF was found in comparison to the control containing only TEGDMA as the diluent monomer (p=0.032). However, even though all composites presented reduction in KH during the SD test, the combination of IBOMA and TEGDMA showed similar reduction in KHN in comparison to the control group (p=0.001), while the total substitution of TEGDMA with IBOMA decreased KHN after SD (p=0.041). Thus, the combination of IBOMA and TEGDMA seem to reduce SD and GF without affecting the properties of resin composites.
Asunto(s)
Resinas Compuestas , Metacrilatos , Bisfenol A Glicidil Metacrilato , Ensayo de Materiales , Polietilenglicoles , Polimerizacion , Ácidos Polimetacrílicos , Solventes , Espectroscopía Infrarroja por Transformada de FourierRESUMEN
OBJECTIVES: This study evaluated the long-term effect on gingival tissues near noncarious cervical lesions after restoration with different composites in association with two different polishing techniques. MATERIALS AND METHODS: This study was conducted on 60 patients as a randomized, split-mouth, single-blind clinical trial and divided into four groups (n = 15) and restored using different composites (Tetric N-Ceram nanohibride or Z350 XT nanoparticles) and polishing materials (Astropol or Sof-Lex). The periodontal parameters analyzed were Silness-Löe plaque index; Silness-Löe gingival index; probing depth, clinical insertion level; and bleeding on probing. Periodontal analysis was performed before scaling and root planing at 30, 60, 120, and 180 days after restoration. STATISTICAL ANALYSIS: The data submitted to the Friedman's test were employed for comparison between groups (p < 0.05). RESULTS: Statistically significant differences between Z350/Astropol and other groups were observed for visible plaque and probing depth. Gingival index Tetric/Sof-Lex, the time factor did not influence the results. All experiment groups exhibited statistically significant differences in the clinical level of insertion when the follow-up time was considered. Percentage of bleeding on probing, in which there was a difference only with regard to group Tetric/Sof-Lex when the time factor was considered. CONCLUSION: The evaluated composites and polishing techniques did not exhibit differences in performance in the periodontal parameters analyzed at the end of 6 months of evaluation.
RESUMEN
Abstract Introduction Adhesive technology has been developed quickly since its introduction about fifty years ago. Its goal is to produce a close contact within enamel and dentin. Failures in this process could result in microleakage, and allow the infiltration of bacteria, fluids and ions. Recent studies have been shown the use of chlorhexidine associated with adhesive systems can be able to inhibit the bacteria action. Objective The aim of this study was to evaluate the addiction of different percentages of chlorhexidine to a self-etch adhesive. Methodology The solution of digluconatechlorhexidine was increased to the primer of the two pass self etch adhesive to create a 0.5%, 1.0% and 2.0% chlorhexidine primer solution and after they were distributed in four groups (G1, G2, G3 and G4). Saliva samples (N=10) were used to test bacteria activity. Result They were spread in a blood medium with filter paper disks containing the different treatments. After the incubation, the inhibitions halos formation were evaluated. Conclusion This study demonstrated that, in vitro, the addition of different percentages of chlorhexidine digluconate to the self-etch adhesive induced inhibited halos at bacteria of saliva samples, independent from their concentration.
Resumo Introdução A tecnologia adesiva vem se desenvolvendo rapidamente desde que foi introduzida há mais de 50 anos. O principal objetivo da adesão é alcançar um íntimo contato entre a estrutura dental e o material restaurador e fornecer adequada união entre o esmalte e a dentina. Objetivo A proposta deste estudo foi avaliar o efeito antibacteriano de um adesivo auto-condicionante de dois passos associado a diferentes concentrações de solução de digluconato de clorexidina (DCHX). Metodologia A solução de digluconato de clorexidina a 20% foi adicionada ao primer do sistema adesivo nas concentrações de 0,5, 1,0 e 2,0% e distribuídas em quatro grupos (G1, G2, G3 e G4). Para o teste de atividade antibacteriana foram utilizadas amostras de saliva (N=10) semeadas em meio de ágar sangue e discos de papel filtro contendo os diferentes grupos. Após incubação, as amostras foram inspecionadas quanto à formação de halo de inibição dos microrganismos através da utilização do paquímetro digital de precisão (0,0001mm) (Mitutoyou Sul Americana Ltda/ Starret Tools ®). Resultado Halos de inibição foram encontrados ao redor de todos os discos de filtro em que foram aplicados o primer acrescido de clorexidina mais o adesivo, bem como ao redor dos discos do controle positivo. Ao redor dos discos do controle negativo e dos discos com primer e adesivo não modificado não foram observados halos de inibição. Conclusão Este trabalho demonstrou que, in vitro, a adição de diferentes concentrações de digluconato de clorexidina ao sistema adesivo produziu halo de inibição dos microrganismos presentes nas amostras de saliva, independente da concentração utilizada.
Asunto(s)
Cementos de Resina , Antibacterianos , Técnicas In Vitro , Clorhexidina , DentinaRESUMEN
ABSTRACT Objective: This study aimed to assess the bond strength and marginal microleakage in composite resin restorations, using the Single Bond Universal adhesive system associated with Ultralux (halogen) and Bluephase (LED) light curing units. Methods: For bond strength, 80 healthy human third molars were divided into halogen light (n=40) and LED (n=40), and subdivided according to the following application techniques for the adhesive system: etch-and-rinse (enamel), self-etching (enamel), etch-and-rinse (dentin), and self-etching (dentin). The teeth were subjected to the microtensile test and the fracture pattern was observed under an optical microscope at 40X magnification; they were analyzed by ANOVA, and Fisher and Tukey's tests (5%). For the marginal microleakage test, 120 class II cavities were prepared in 60 healthy human third molars that were randomly divided into halogen light (n=30) and LED (n=30), and subdivided according to the following application techniques for the adhesive system: etch-and-rinse, selective etching, and self-etching. The teeth were thermocycled 2000 times (±5/55°C), stained in 5% basic fuchsin and sectioned for qualitative and quantitative assessments; they were analyzed by Kruskall-Wallis and Dunn tests (5%). Results: For the bond strength of enamel and dentin, the adhesive application with prior acid etching was better than self-etching (p<0.0001), regardless of the type of light curing unit (p<0.05). Etch-and-rinse showed the lowest microleakage values (p<0.0001). Conclusion: Etch-and-rinse obtained the best results relative to the other application techniques for the adhesive system in both tests, regardless of the type of light curing unit.
RESUMO Objetivo: Avaliar a resistência de união e microinfiltração marginal em restaurações de resina composta, utilizando sistema adesivo Single Bond Universal associado com fotoativadores Ultralux (halógeno) e Bluephase (LED). Métodos: Para resistência de união, oitenta terceiros molares humanos hígidos foram divididos: Halógena (n=40); LED (n=40), sendo subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total-esmalte; autocondicionante-esmalte; condicionamento total-dentina; autocondicionante-dentina. Os dentes foram submetidos ao teste de microtração e o padrão de fratura foi observado em microscópio ótico - 40X de aumento, analisadas pelos testes ANOVA, Tukey e Fisher (5%). Para o ensaio de microinfiltração marginal, 120 cavidades classe II foram preparadas em sessenta terceiros molares humanos hígidos, aleatoriamente divididos: Halógena (n=30); LED (n=30) e subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total; condicionamento seletivo; autocondicionante. Os dentes foram termociclados 2000 vezes (±5/55ºC), corados em fucsina básica 5% e seccionados para avaliações qualitativa e quantitativa, analisados pelos testes Kruskall-Wallis e Dunn (5%). Resultados: Para resistência de união em esmalte e dentina, a aplicação do adesivo com condicionamento ácido prévio, foi melhor que o autocondicionante (p<0.0001), independentemente do tipo de fotoativador utilizado (p<0.05). O condicionamento total mostrou os menores valores de microinfiltração, (p<0.0001). Conclusão: O condicionamento total, obteve os melhores resultados em relação às outras técnicas de aplicação do sistema adesivo em ambos os testes, independentemente do tipo de aparelho fotoativador.
RESUMEN
Objetivo: realizar uma revisão de literatura sobre materiais, técnicas de confecção, vantagens, desvantagens e limitações das restaurações cerâmicas multicamadas e monolíticas. Revisão de literatura: embora as cerâmicas odontológicas sejam utilizadas para confecção de restaurações dentárias indiretas, porque têm excelentes propriedades mecânicas e estéticas, são materiais susceptíveis à fratura sob forças oclusais. Para compensar essa fragilidade, restaurações multicamadas são confeccionadas associando um material mais resistente para a infraestrutura e a posterior aplicação de cerâmica para recobrimento estético. Porém, as restaurações multicamadas apresentam como desvantagem o possível lascamento da cerâmica de recobrimento. Essas falhas comprometem a restauração funcional e a estética, exigindo a substituição da peça protética em muitos casos. Sendo assim, devido à evolução de sistemas cerâmicos e técnicas de processamento, surgiram as restaurações cerâmicas monolíticas fabricadas com um único material, a fim de superar tal limitação. Nesse sentido, diferentes materiais e técnicas são apresentados na literatura para a confecção de restaurações cerâmicas monolíticas. Considerações finais: as restaurações multicamadas têm bom resultado estético, porém podem apresentar lascamento da cerâmica de recobrimento. Essa limitação é superada pelo uso de um único material para as restaurações monolíticas, mas o resultado estético pode ser limitado. De um modo geral, a literatura demonstra um bom comportamento clínico para as restaurações cerâmicas multicamadas e monolíticas, quando a técnica de confecção e o sistema cerâmico são bem indicados. (AU)
Objective: the aim of this study was to conduct a literature review about the materials, techniques, advantages, disadvantages and limitations of multilayer and monolitic ceramic restorations. Literature review: although dental ceramics have been used for fabrication of dental restorations due to its good esthetic and mechanical properties, it is a material prone to fracture under oclusal loading. To surpass such fragility, multilayer restorations are fabricated using a resistant framework material associated to esthetic veneering ceramic. However, multilayer restorations present risk to chipping of veneering ceramic. Those failures represent a functional and esthetic problem, leading to restoration replacement. So, the evolution of ceramic systems and techniques generated monolitic restorations using a single material. Several materials and techniques are presented in the literature for fabrication of monolitic ceramic restorations. Final considerations: multilayer restorations present good esthetic result but delamination of veneering ceramic can occur. Such limitation is solved using a single material in monolitic restorations, but esthetic result is limited. In general, literature shows appropriate clinical performance for both multilayer and monolitic ceramic restorations when technique and materials are well indicated. (AU)
Asunto(s)
Humanos , Cerámica/química , Restauración Dental Permanente/métodos , Circonio/química , Cerámica/uso terapéutico , Fracaso de la Restauración Dental , Litio/químicaRESUMEN
Introduction: There is a growing demand for aesthetic restorations and the polymerized composite resins are the most used material in these procedures. In order to achieve greater resistance to solubilization proper polymerization is required. Objective: Evaluate the influence of three photoactivation techniques, on sorption and solubility of three composite resins. Materials and methods: 90 test samples measuring 8 mm diameter and 1 mm thick were made and divided into 9 groups (n=10) of resins -Filtek Z350 XT, Tetric N-Ceram and IPS Empress Direct, each of them was polymerized with LED Bluephase, using the techniques: Conventional, Soft-Start (SS) and Pulse Delay (PD). Afterwards they were placed in desiccator with silica gel at 98.6 F and weighed daily until obtaining a constant mass (m1). Then they were immersed in deionized water for seven days and weighed again (m2). The test sample reconditioning was performed using the m1 procedure, until a constant mass (m3 ) was obtained. The sorption and solubility values were calculated and subjected to ANOVA test (two-way), followed by Tukey post hoc, p<0.05. Result: There were no statistically significant differences in sorption and solubility among the studied resins when photoactivation techniques were compared. For solubility analysis, statistically significant differences were observed among the materials. The results for composite resin Filtek Z350 XT presented higher statistical hybridization values than those of the other evaluated resins. Conclusion: The different forms of photoactivation had no influence on the sorption and solubility of the tested composite resins.
Introdução: Há uma crescente demanda por restaurações estéticas, sendo as resinas compostas polimerizadas o material mais utilizados nesses procedimentos. Visando uma maior resistência à solubilização, uma polimerização adequada é necessária. Objetivo: Avaliar a influência de três técnicas de fotoativação na sorção e na solubilidade de três resinas compostas. Material e método: Foram confeccionados 90 corpos-de-prova, com 8 mm de diâmetro e 1 mm de espessura, divididos em 9 grupos (n = 10) de resinas - Filtek Z350 XT, Tetric N-Ceram e IPS Empress Direct, cada uma elas polimerizada com LED Bluephase, utilizando as técnicas: Convencional, Soft-Start (SS) e Pulse Delay (PD). Posteriormente foram colocadas em dessecador com sílica gel a 98,6 F e pesadas diariamente até obtenção de massa constante (m1). Depois foram imersos em água desionizada durante sete dias e pesados novamente (m2). O recondicionamento da amostra de teste foi realizado utilizando o procedimento m1, até que uma massa constante (m3) fosse obtida. Os valores de sorção e solubilidade foram calculados e submetidos ao teste ANOVA (two-way), seguido por Tukey post hoc, p <0,05. Resultado: Não houve diferenças estatisticamente significantes para sorção e solubilidade nas resinas estudadas quanto as técnicas de fotoativação. Para análise de solubilidade, foram observadas diferenças estatisticamente significantes entre os materiais. Os resultados para resina compostaFiltek Z350 XT apresentaram valores de hibridação estatísticos superiores aos das outras resinas compostas avaliadas. Conclusão: As diferentes formas de fotoativação não influenciaram a sorção e solubilidade das resinas compostas testadas.
Asunto(s)
Solubilidad , Análisis de Varianza , Resinas Compuestas , Estética Dental , PolimerizacionRESUMEN
Objetivo: Avaliar a influência de diferentes soluções de irrigação cavitária sobre a resistência de união de um cimento resinoso de dupla polimerização. Material e Método: A partir de incisivos bovinos, foram obtidos 4 grupos (n=15), divididos aleatoriamente de acordo com a solução irrigadora empregada na limpeza cavitária, sendo: G0 - soro fisiológico + condicionamento ácido; G1 EDTA + condicionamento ácido; G2 - Clorexidina 2% + condicionamento ácido + clorexidina 2% e G3 - soro fisiológico + condicionamento ácido + clorexidina 2%. Foram confeccionados cilindros de cimento resinoso para cada coroa, utilizando-se uma matriz de Tygon com diâmetro interno de 1 mm e altura de 2 mm. O teste de resistência adesiva por microcisalhamento foi realizado após 3 meses de armazenamento dos espécimes em soro fisiológico a 37ºC. Os dados foram submetidos ao teste de Kruskall-Wallis, seguido do teste de Dunn (p<0,05). Resultados: Os grupos G0, G1 e G3 não apresentaram diferenças significativas entre si (p>0,05). Os menores valores foram observados no grupo G2 (p<0,05). Conclusões: As soluções irrigadoras EDTA e soro fisiológico utilizadas previamente ao condicionamento ácido da dentina não interferiram, significativamente, na resistência de união, porém, a solução de clorexidina utilizada após o condicionamento ácido influenciou negativamente nos valores de resistência de união.
Objectives: This study aimed to evaluate the influence of different cavity irrigation solutions on the bond strength of a dual-curing resin cement. Methods: From bovine incisors, 4 groups (n=15), were randomly divided according to the irrigating solution for cavity cleaning: G0 saline + acid etching; G1 EDTA + acid etching; G2: Chlorhexidine 2% + acid etching + Chlorhexidine 2%; and G3 Saline + acid etching + Chlorhexidine 2%. Resin cement cylinders were made for each crown, using a Tygon matrix with internal diameter of 1 mm and height of 2 mm. The specimens were stored for 3 months at 37oC, and then subjected to microshear tests. Data were statistically analyzed by Kruskal-Wallis test followed by Dunn (p<0.05). Results: There were no statistically significant differences between G0, G1 and G3 groups (p>0.05). The lowest values were observed in G2 group (p<0.05). Conclusion: The irrigation solutions EDTA and saline used before to the acid etching of dentin did not interfere, significantly, in the bond strength, however, the solution of chlorhexidine used after the acid etching influenced negatively.
RESUMEN
As restaurações provisórias têm papel importante para diagnóstico e plano de tratamento em reabilitação com prótese fixa. Quando há necessidade de procedimentos cirúrgicos pré-protéticos, meios adicionais de controle de placa bacteriana devem ser indicados, mas pouco se sabe sobre os efeitos que podem produzir na superfície de restaurações provisórias. Proposição: este estudo teve como objetivo avaliar o efeito de dois enxaguatórios bucais na dureza de duas resinas usadas para confecção de provisórios protéticos. Material e Métodos: resina acrílica autopolimerizável poli(metil metacrilato) Dencrilay Speed e resina bisacrílica Protemp 4; dois enxaguatórios bucais, Periogard (digluconato de clorexidina 0,12%) e Oral-B sem álcool, tendo soro fisiológico como grupo controle. Foram confeccionadas 60 amostras, 30 para cada resina, as quais foram divididas em 6 grupos experimentais (n=10). As amostras foram imersas nas respectivas soluções para bochecho durante 10 minutos por dia, por um período de 30 dias. Após, foram submetidas a ensaios de microdureza utilizando o penetrador tipo Knoop. Resultados: a resina acrílica Dencrilay apresentou os maiores valores de dureza, no entanto apresentou redução na dureza quando imersa no enxaguatório Periogard. A resina bisacrílica Protemp 4 não apresentou diferença nos valores de microdureza de superfície quando imersa nas soluções utilizadas. Conclusão: a resina acrílica apresentou redução na dureza de superfície após imersão em solução de clorexidina 0,12%. Implicações clínicas: a resina bisacrílica, apesar de menor dureza, apresentaria superfície mais estável em meio bucal, mesmo com o uso diário de enxaguatórios bucais
Temporary restorations have important role for diagnosis and treatment plan in rehabilitation with fixed prosthesis element. When pre-prosthetic surgical procedures are required, additional means of controlling plaque must be indicated, but little is known about the effects it can produce on the surface of provisional prosthetic restorations. Purpose: To evaluate the effect of two mouthrinses on the hardness of two resins used in temporary restorations. Material and Method: Acrylic resin poly(methyl methacrylate) Dencrilay Speed and bisacrylic resin Protemp 4, two mouthrinses, Periogard (chlorhexidine digluconate 0.12 %) and Oral- B without alcohol and saline solution as control group. Sixty samples were prepared, 30 for each resin, which were divided into 6 groups (n = 10). The specimens were immersed in respective solutions for 10 minutes per day, for 30 days. Then, microhardness tests were performed using the Knoop indenter. Data were subjected to analysis of variance and Tukey's test, with a confidence interval of 95%. Results: Dencrilay acrylic resin had the highest values of hardness, however, it showed a reduction in hardness when immersed in the mounthrinse Periogard. The bisacrylic resin Protemp 4 showed no difference in the values of surface microhardness when immersed in the solutions used. Conclusion: The acrylic resin showed a reduction in surface hardness after immersion in 0.12% chlorhexidine solution. Clinical Implications: Bisacrylic resin, although less hard, would have a more stable surface in oral environment, even with the daily use of mouthrinses.
Asunto(s)
Prótesis Dental , Clorhexidina/uso terapéutico , Desinfectantes/uso terapéuticoRESUMEN
Uma das mais importantes questões da Odontologia atual é a preservação do esmalte dentário. Nesse contexto, os laminados cerâmicos apresentam excelente reprodução das propriedades ópticas da estrutura dental, especialmente em espessuras mínimas. Este artigo apresenta um caso clínico, esclarecendo indicação, vantagens, desvantagens e limitações das facetas cerâmicas. Concluiu-se que, atualmente, os laminados cerâmicos são a melhor opção de tratamento nos casos de estética elevada, uma vez que é uma reabilitação conservadora que imita fielmente a estrutura dental e sua forma (AU).
One of the most important issues of today's Dentistry is the preservation of sound enamel. In this context, ceramic veneers present excellent reproduction of the optical properties of the dental structure, especially in minimal thicknesses. The current article aims to present a case report, clarifying the indication, advantages, disadvantages, and limitations of laminate veneers. We concluded that the ceramic veneers are currently the best treatment option for elective aesthetic cases, once it is an extremely conservative rehabilitation that faithfully mimics the dental structure and shape, besides being a very predictable treatment (AU).
Asunto(s)
Persona de Mediana Edad , Cerámica , Esmalte Dental , Coronas con Frente Estético , Rehabilitación Bucal , Sonrisa , Brasil , Informes de Casos , Cementación/métodos , Prótesis Dental , Fotografía Dental/instrumentación , Odontología , Estética DentalRESUMEN
O restabelecimento da dimensão vertical de oclusão (DVO) de pacientes é uma tarefa complexa e, em virtude disso, diversos métodos são empregados, rotineiramente, na busca do correto relacionamento maxilomandibular. Sempre que indicado, o aumento da DVO deve ser feito com próteses fixas para melhor adaptação do organismo à nova condição oclusal. O presente caso clínico descreve uma situação de acentuada perda de DVO, em um paciente parcialmente edentado, com desgastes dentais severos. Depois dessa dimensão ter sido recuperada por meio de coroas provisórias, sem que houvesse presença de alterações funcionais, próteses parciais fixas foram confeccionadas. A utilização de próteses fixas no caso em questão facilitou a obtenção de uma guia canina e guia anterior mais precisas, pelo grande número de elementos pilares. O resultado final deste caso clínico comprovou a efetividade de restabelecer adequadamente a DVO perdida, por meio da confecção de coroas provisórias e próteses fixas sem causar dores e/ou desconforto ao paciente.
Reestablishment of occlusal vertical dimension (OVD) is a complex task therefore different methods are used routinely in the search of proper maxillomandibular relation. When indicated, the increasing of VDO must be done with fixed prosthesis for a better adaptation of the organism to the new occlusal condition. The reported clinical case describes a situation of severe VDO loss in a partially edentulous patient with severe dental wear. After recovery of this position through temporary prosthesis, without any major functional changes, fixed partial dentures (fPD) were used. The use of fPD, in this case has enabled a more precise canine and anterior guidance due to a large number of abutments elements. final results have proved the effectiveness of the use of temporary prosthesis and fixed prostheses proper restoration of lost VDO, without pain and/or discomfort to the patient.
Asunto(s)
Humanos , Masculino , Anciano , Coronas , Dentadura Parcial Fija , Dentadura Parcial Removible , Rehabilitación Bucal , Dimensión VerticalRESUMEN
INTRODUCTION: Reduction of biofilm on dentures is important for maintaining denture wearers' health. OBJECTIVE: The aim of this study was to assess the effectiveness of toothbrush handles individually adapted in reducing of biofilm on dentures. MATERIALS AND METHODS: Study participants were 16 residents of the condo for the elderly, denture wearers, functionally independent and without cognitive impairment. Participants were randomly divided into two groups: Group 1 (adapted toothbrush handles) and Group 2 (conventional toothbrush). Biofilm from the inner surface of the basal area of the denture was observed using 5% erythrosine. Images obtained before starting the use of toothbrushes, after 7 and 21 days were sent for computer analysis. RESULTS: The average amount of biofilm on the first day was considered severe in both groups. At the end of the experiment, the average biofilm coverage in Group 1 was 44.7% (13.1% reduction) and in Group 2 it was 48.6% (4.8% reduction). However, the Friedman analysis of variance test showed that the reduction was statistically significant (p< 0.05) only in Group 1, demonstrating the effectiveness of the adapted brushes. CONCLUSION: The findings of this pilot study indicated that for the reduction of biofilm on dentures the adapted toothbrush handles were superior to the conventional type.
RESUMEN
Disinfecting dental impressions is necessary to decrease the risk of cross-contamination in dental offices. Ultrasonic nebulization has been mentioned as a microbicidal technique that can be used to disinfect contaminated dental impressions. This study compared the microbicidal effect of 2% glutaraldehyde and 0.2% peracetic acid for the disinfection of dental impressions made with vinyl polysiloxane, using 2 disinfection methods: immersion and ultrasonic nebulization. Bactericial efficacy was examined using Staphylococcus aureus and Bacillus atrophaeus as indicators. Thirty impressions were obtained and distributed randomly in 5 groups (n = 6). Group 1 was immersed in 2% glutaraldehyde immersion for 10 minutes, Group 2 was immersed in 0.2% peracetic acid for 10 minutes, Group 3 underwent ultrasonic nebulization for 10 minutes in 2% glutaraldehyde solution, Group 4 underwent ultrasonic nebulization for 10 minutes in 0.2% peracetic acid solution, and Group 5 was a control group that received no disinfectant. Both solutions experienced a 100% reduction in microorganisms following ultrasonic nebulization, as did peracetic acid following immersion; however, immersion in glutaraldehyde demonstrated lower values of reduction in B atrophaeus group, with a statistically significant difference compared with the other experimental groups.
Asunto(s)
Desinfectantes Dentales , Materiales de Impresión Dental , Técnica de Impresión Dental , Desinfectantes , Desinfección , Glutaral , Staphylococcus aureus , UltrasonidoRESUMEN
Introdução: A contaminação do substrato dentinário pode interferir na qualidade de união entre materiais adesivos e o dente. Objetivo: Investigar a influência de diferentes soluções de irrigação na resistência de união de um cimento resinoso. Material e Método: Foram selecionadas 40 coroas dentais bovinas, divididas em quatro grupos: G0 = soro; G1 = clorexidina; G2 = EDTA; G3 = clorexidina 0,12%, após condicionamento ácido. Em seguida, foram confeccionados cilindros de cimento resinoso utilizando-se uma matriz de Tygon com diâmetro interno de 1 mm e 2 mm de altura. A fotoativação foi realizada por aparelho de luz LED com 900 mW/cm² por 40 segundos. Foram confeccionados quatro cilindros de cimento resinoso para cada coroa bovina, totalizando 40 corpos de prova de cimento resinoso para cada grupo avaliado. O teste de resistência adesiva por microcisalhamento foi realizado após 24 horas. Decorrido esse período, os cilindros de cimento resinoso foram testados em uma máquina universal de ensaios (EMIC). Os dados obtidos foram submetidos à análise estatística pelos testes ANOVA e Tukey (p = 0,001). Resultado: Não houve diferenças estatisticamente significativas entre os grupos estudados, com exceção para o G3, que apresentou de forma significativa os menores valores de resistência adesiva. Conclusão: As diferentes soluções irrigadoras utilizadas previamente ao condicionamento ácido na dentina não interferem na resistência de união por microcisalhamento.
Introduction: The contamination of dentin can interfere with the quality of union between adhesives and tooth. Objective: Was to investigate the influence of different irrigation solutions on bond strength of a resin cement. Material and Method: Were selected 40 dental bovine crowns divided into four groups: G0= physiologic serum, G1= chlorhexidine, G2= EDTA, G3= 0.12% chlorhexidine after acid etching. Then the cylinders were fabricated resin cement using a matrix of Tygon with an internal diameter of 1mm and 2mm in height. The polymerization was carried out by LED light unit with 900 mW/cm² for 40 seconds. 4 cylinders were made of resin cement for each bovine crown, totaling 40 body-of-proof resin cement for each group evaluated. The test microshear bond strength was performed after 24 hours. After this period, the resin cement cylinders were tested in a universal testing machine (EMIC). Data were statistically analyzed by ANOVA and Tukey (p = 0.001). Result: There were no statistically significant differences between groups, except for the G3 which showed significantly lower values of bond strength. Conclusion: The different irrigating solutions used prior to etching dentin not interfere in the bond strength microshear.
Asunto(s)
Animales , Bovinos , Análisis de Varianza , Recubrimientos Dentinarios , Cementos de Resina , Resistencia al Corte , Detergentes , Luces de Curación Dental , Grabado Ácido Dental , Clorhexidina , SueroRESUMEN
Este trabalho avaliou a sorção e a solubilidade de uma resina composta nanoparticulada em três meios líquidos diferentes: água destilada, Coca-Cola® e etanol/água a 75%, em função de dois períodos de armazenamentos: 7 e 15 dias. Foram confeccionados 30 espécimes, acondicionados em sílica gel azul, desidratada a 37°C, por 24 horas. Em seguida, foram pesados em balança analítica de precisão, repetindo-se até que se obtivesse massa constante (m1). Com a obtenção da m1, os espécimes foram subdivididos em 6 grupos e armazenados na solução. Três grupos permaneceram por 7 dias, e os outros três, por 15 dias. Após o período de armazenamento, os espécimes foram removidos, lavados, secos, pesados para a obtenção de uma segunda medida de massa, denominada m2. Os espécimes foram, então, recondicionados em estufa a 37°C. Mensurações de massa foram realizadas durante a desidratação, a cada 24 horas, obtendo-se a m3. Os dados de sorção e solubilidade foram calculados e submetidos à análise estatística. A resina nanoparticulada mostrou-se resistente à degradação química em meio ácido e em meio aquoso, mas foi suscetível à degradação, quando imerso em solução de etanol/água a 75%, apresentando solubilidade, sem diferença estatística entre os períodos de armazenamento.
This study evaluated the sorption and solubility of resin composite nanoparticle in three different liquid : distilled water, Coca-Cola ® and ethanol / water at 75%, according two periods of stores: 7 and 15 days. We prepared 30 specimens, packed in plastic container containing silica gel blue dehydrated and taken to an incubator at 37 ° C for 24 hours. Following, we weighed in analytical balance, and repeated until achieving constant mass (m1) on every 24 hour period. By getting the m1, the specimens were been divided into six groups and stored separately in 5 mL of each solution. Three groups were been maintained for 7 days and the other three for 15 days. After the storage period, the specimens were removed, washed, dried, weighed to obtain a second measure of mass, called m2. The specimens was reconditioned at 37 ° C. Mass measurements were performed during dehydration, every 24 hours, getting the dough reconditioned, with constant value of mass, called m3. The Data from sorption and solubility, we calculated and subjected to statistical analysis. The composite resin Filtek Z350 was found to be resistant to chemical degradation in acid and aqueous, but was susceptible to degradation when immersed in a solution of ethanol / water at 75%, with solubility, no statistical difference between the periods of storage.