Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Br J Radiol ; 90(1080): 20170187, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28937271

RESUMEN

OBJECTIVE: The aim of this work was to simulate a 6MV conventional breast 3D conformational radiation therapy (3D-CRT) with physical wedges (50 Gy/25#) in the left breast, calculate the mean absorbed dose in the body organs using robust models and computational tools and estimate the secondary cancer-incidence risk to the Brazilian population. METHODS: The VW female phantom was used in the simulations. Planning target volume (PTV) was defined in the left breast. The 6MV parallel-opposed fields breast-radiotherapy (RT) protocol was simulated with MCNPx code. The absorbed doses were evaluated in all the organs. The secondary cancer-incidence risk induced by radiotherapy was calculated for different age groups according to the BEIR VII methodology. RESULTS: RT quality indexes indicated that the protocol was properly simulated. Significant absorbed dose values in red bone marrow, RBM (0.8 Gy) and stomach (0.6 Gy) were observed. The contralateral breast presented the highest risk of incidence of a secondary cancer followed by leukaemia, lung and stomach. The risk of a secondary cancer-incidence by breast-RT, for the Brazilian population, ranged between 2.2-1.7% and 0.6-0.4%. CONCLUSION: RBM and stomach, usually not considered as OAR, presented high second cancer incidence risks of 0.5-0.3% and 0.4-0.1%, respectively. This study may be helpful for breast-RT risk/benefit assessment. Advances in knowledge: MCNPX-dosimetry was able to provide the scatter radiation and dose for all body organs in conventional breast-RT. It was found a relevant risk up to 2.2% of induced-cancer from breast-RT, considering the whole thorax organs and Brazilian cancer-incidence.


Asunto(s)
Neoplasias Inducidas por Radiación/etiología , Neoplasias Primarias Secundarias/etiología , Neoplasias de Mama Unilaterales/radioterapia , Femenino , Humanos , Fantasmas de Imagen , Dosis de Radiación , Radiometría , Dosificación Radioterapéutica , Radioterapia Conformacional/efectos adversos , Radioterapia Conformacional/métodos , Medición de Riesgo , Factores de Riesgo
2.
Braz. J. Pharm. Sci. (Online) ; 53(1): e16092, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-839463

RESUMEN

ABSTRACT The aim of this study was to create and test a new mice 3D-voxel phantom named DM_BRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-of-art in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DM_BRA model was performed at 0.015, 0.1, 0.5, 1 and 4 MeV photons with heart-source. Specific Absorbed Fractions (SAF) data were compared with literature data. The organ masses of DM_BRA correlated well with existing models based on the same dataset; however, few small organ masses hold significant variations. The SAF data in most simulated cases were statistically equal to a significant level of 0.01 to the reference data.


Asunto(s)
Alfabetización Digital , Dosimetría/análisis , Ratones/clasificación , Radiometría/métodos
3.
Appl Radiat Isot ; 117: 123-127, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26778764

RESUMEN

The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine internal monitoring of occupationally exposed individuals. The determination of photon emitting radionuclides in the human body requires calibration of the detector in specific counting geometries. The calibration process uses physical phantoms containing certified activities of the radionuclides of interest. The objective of this work was to obtain calibration efficiency curves of the Whole Body Counter in operation at the LDI/CDTN using a BOMAB physical phantom and Monte Carlo simulations.


Asunto(s)
Método de Montecarlo , Radioisótopos/análisis , Radioisótopos/normas , Programas Informáticos , Recuento Corporal Total/instrumentación , Recuento Corporal Total/normas , Brasil , Calibración/normas , Análisis de Falla de Equipo/normas , Humanos , Laboratorios , Fantasmas de Imagen , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA