Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39112763

RESUMEN

PURPOSE: The role of transobturator-cable-fixation (TOCF) in traumatic symphyseal rupture of the pelvic ring remains unclear. This case series aims to evaluate TOCF in complex and revision cases in pelvic surgery. METHODS: A retrospective analysis of a chronological case series was conducted, studying pelvic fractures stabilized using TOCF between January 2006 and December 2022. The variables considered included age, gender, fracture classification, Injury Severity Score (ISS), Body Mass Index (BMI), trauma mechanism, time to surgery, fixation technique, hospital duration, complications, status on discharge (Glasgow Outcome Scale; GOS), follow-up time and indication for the use of TOCF. RESULTS: All patients (N = 7) were male with a mean age of 64 years and a mean BMI of 29. The mean ISS was 45, with the lowest ISS of 25, indicating that only polytraumatized patients were included. Two anterior-posterior-compression-, four lateral-compression-, and one vertical-shear-pelvic-injury were identified. TOCF was added in six cases to support symphyseal plating and in one case to external fixation. The mean hospital stay was 49 days and the mean follow-up duration was 8.5 months. No complications associated with TOCF were observed during the surgical procedure or follow-up. CONCLUSION: TOCF showed no procedure-associated complications and effectively supported symphyseal healing in all cases. The main indications were obesity, poor bone quality in elderly patients, and revision cases. TOCF could be considered as a last treatment option in open-book pelvic injuries where plating or external fixation is at risk to fail.

2.
Open Access J Sports Med ; 15: 91-100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39139214

RESUMEN

Purpose: This study aims to conduct an epidemiological investigation into the types and causes of injuries during CrossFit® training in Germany. Patients and Methods: Voluntary athletes from various German CrossFit® gyms participated, providing personal information, training habits, and details on injuries through a standardized questionnaire. Results: The study involved 308 participants, with an equal sex split, a peak age of 20-40, and a BMI of 24.3 ± 3.3 kg/m2. Most participants trained for over two years (49.4%), primarily in supervised groups. Motivations for engaging in CrossFit® included health prevention (33.1%), athletic training (32.8%), and work-life balance support (17%). Injuries were reported by 28.6% of participants, with 61.4% experiencing single injuries. The majority of injuries (55.3%) occurred during the middle of workouts. Injury types included wounds (23.3%), contusions, sprains, or strains (cumulative 30.8%), and fractures (2.9%). Almost all injured individuals (96.5%) had a time-loss injury, with a return to sport ranging from a day to over three months. Treatments varied, with 50.6% not requiring medical intervention, 34.1% undergoing physiotherapy, 21.2% receiving medication and 8.2% needing surgery. Barbell exercises, notably Snatch and Clean, were main exercises with association to injuries, accounting for 36.3%. The Box Jump stood out as the exercise with the highest isolated injury prevalence (14.3%). Notable injury causes included falls during Pull-Ups and lumbar disc herniation linked to Deadlifts. Following injuries, 45.8% of participants made training adjustments. Conclusion: This study provides an epidemiological investigation into the types and causes of injuries during CrossFit® training in Germany. The shoulder and knee joint exhibited the highest injury prevalence. Barbell exercises, box jumps, and bar pull-ups were identified as major exercises with association to injuries. Prevention through technical training and the incorporation of soft boxes could reduce the risk of injuries in CrossFit®.


This study looks at the types and causes of injuries during CrossFit® training in Germany. A total of 308 CrossFit® athletes took part, with an equal number of men and women, mostly aged 20-40, and an average BMI of 24.3 ± 3.3 kg/m². Most had trained for over two years, often in supervised groups, and were motivated by health, fitness, and balancing work and life. About 28.6% of participants reported injuries, mostly single injuries happening in the middle of workouts. The types of injuries included cuts, bruises, sprains, strains, and fractures, with the shoulder and knee being the most commonly affected areas. Notably, exercises involving barbells like the Snatch and Clean caused a significant number (36.3%) of injuries, followed by Box Jumps (14.3%) and bar pull-ups. Causes of injuries included falls during pull-ups and back injuries from Deadlifts. After getting injured, nearly half of the participants changed their training routines. Treatments varied, with some not needing medical help and others undergoing physiotherapy, taking medication, or having surgery. The findings suggest that focusing on proper technique and using softer equipment, like softer landing surfaces for Box Jumps, could help reduce the risk of injuries in CrossFit® training.

3.
EFORT Open Rev ; 9(8): 827-836, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39087500

RESUMEN

Purpose: To compare anterior plate fixation (SP fixation) both alone and in combination with an additional posterior sacroiliac screw (SP+SIS fixation) as a treatment for pelvic ring injuries with widening of the pubic symphysis and disruption to the anterior sacroiliac ligaments. Methods: To find studies with pelvic ring injuries (APC II; B2.3d) and SP or SP+SIS fixation, a systematic literature review was conducted by searching four databases. A protocol was published a priori at Open Science Framework (https://doi.org/10.17605/OSF.IO/3YHAV). Exclusion criteria included perineal injuries, chronic instability of the symphysis, complete sacroiliac separation, and pediatric patients (age <18 years). Primary outcomes of interest were defined as implant failure, health-related quality of life, and revision rate. Results: Altogether, 1861 studies were screened, and 40 studies qualified for full-text analysis. In total, 14 studies (two surveys, six biomechanical studies, and six retrospective clinical studies) were included. The surveys revealed that surgeons who had more recently begun practicing were more likely to use posterior fixation (SP+ISS). The biomechanical studies were heterogenous and did not yield a uniform pattern. In clinical studies, 117 patients (45%) received SP fixation, and 142 patients (55%) received SP+SIS fixation. Complications occurred in 31 SP patients (30%) and in five SP+SIS patients (3.5%). Conclusion: A high risk of bias was uncovered, and reporting was found to be incomplete. SP+SIS may have the potential to improve outcomes, but the evidence remains too inconclusive to draw reliable recommendations.

4.
Open Access J Sports Med ; 15: 67-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38975566

RESUMEN

Purpose: While injuries among elite tennis athletes are extensively documented, a notable research gap exists regarding tennis injuries among club-level players. This study examines tennis injuries in German league players, with a particular emphasis on the impact of racquet properties and court surfaces, distinguishing between chronic and acute injuries. Patients and Methods: Retrospectively analyzing data from 600 tennis players over a 1.5-year period, a standardized questionnaire covered anthropometrics, injury characteristics, equipment usage, and court surface conditions. Results: The study identified 1012 tennis-related injuries, averaging 1.7 per player. Acute injuries predominantly affected the lower extremity (56%), with ankle injuries being the most prevalent, and ligaments were the most commonly affected structures (36.4%). Chronic complaints (reported by 364 athletes) focused on the upper extremity (63.2%), primarily tendon injuries (56.8%). Racket properties exhibited no significant impact on chronic upper extremity injuries. Conclusion: This study highlights a high incidence of acute lower extremity injuries, especially ankle ligament injuries, among German league tennis players. It offers crucial insights for devising targeted injury prevention strategies applicable to amateur, semi-professional, and professional tennis players, despite finding no significant link between racquet material and chronic upper extremity injuries.

5.
Front Bioeng Biotechnol ; 12: 1392631, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38895558

RESUMEN

Purpose: The ideal treatment of peri-implant femur fractures (PIFFs) remains unclear due to the thin clinical and biomechanical evidence concerning the most suitable form of osteosynthesis. The purpose of the present study was thus to determine the biomechanical stability that results from combining a cephalomedullary nail and a plate for proximal PIFFs, especially when the nail-plate docking technique is applied. Methods: Twenty four PIFFs were simulated in both 12 foam and 12 composite specimens and were stabilized via a combination of a cephalomedullary nail and a plate. The control group (n = 6) had a nail and a plate without a connection, while the intervention group (n = 6) had a screw that connected the plate with the interlocking screw hole of the nail, thereby creating a nail-plate docking system. The specimens were evaluated under axial and torsional loading using a material-testing machine and a 3D metrology system. Results: The data regarding stiffness, failure load, and failure displacement showed significantly higher stability for specimens without nail-plate docking. For docked specimens, a non-significant trend toward a higher resistance to torque was observed. Both techniques displayed no significant difference in fracture gap displacement or total displacement. Conclusion: The present study suggests that nail-plate docking of a cephalomedullary nail, and a plate significantly decreases the stiffness and stability of osteosynthesis under axial loading. However, there seems to be a tendency toward higher resistance to torque. Therefore, surgeons should consider this technique if higher torsional stability is necessary, and they should decide against it, if axial stability is preferred.

6.
Technol Health Care ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38848207

RESUMEN

BACKGROUND: Coverage of soft tissue defects following surgery at the trochanteric area is challenging. Revision surgery in case of compromised wound healing may lead to soft tissue defects requiring reconstruction with pedicled or free flaps. Previous access to the hip joint may jeopardize neurovascular structures relevant to the flap. OBJECTIVE: In this study, we evaluated if the use of a pedicled anterior lateral thigh (ALT) flap is a valuable option for soft tissue reconstruction. METHODS: In this retrospective study, seven patients were included. Defect etiology was tumor resection in one case, screw osteosynthesis in another case and total hip arthroplasty in three cases. All patients underwent reconstruction by proximal pedicled anterior lateral thigh (ALT) flap. RESULTS: Pedicled ALT flap was a safe procedure in all cases. One patient showed delayed wound healing with need for additional surgery. No further complications were observed. CONCLUSIONS: Pedicled ALT flap transfer represents a reliable option for soft tissue coverage in the trochanteric area after primary surgery such as hip arthroplasty, osteosynthesis or tumor resection.

7.
Unfallchirurgie (Heidelb) ; 127(4): 290-296, 2024 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-37985517

RESUMEN

BACKGROUND: In order to continue to efficiently provide both personnel-intensive and resource-intensive care to severely injured patients, some hospitals have introduced individually differentiated systems for resuscitation room treatment. The aim of this study was to evaluate the concept of the A and B classifications in terms of practicability, indications, and potential complications at a national trauma center in Bavaria. METHODS: In a retrospective study, data from resuscitation room trauma patients in the year 2020 were collected. The assignment to A and B was made by the prehospital emergency physician. Parameters such as the injury severity score (ISS), Glasgow outcome scale (GOS), upgrade rate, and the indication criteria according to the S3 guidelines were recorded. Statistical data comparisons were made using t­tests, χ2-tests, or Mann-Whitney U­tests. RESULTS: A total of 879 resuscitation room treatments (A 473, B 406) met the inclusion criteria. It was found that 94.5% of resuscitation room A cases had physician accompaniment, compared to 48% in resuscitation room B assignments. In addition to significantly lower ISS scores (4.1 vs. 13.9), 29.8% of B patients did not meet the treatment criteria defined in the S3 guidelines. With a low upgrade rate of 4.9%, 98% of B patients had a GOS score of 4 or 5. CONCLUSION: The presented categorization is an effective and safe way to manage the increasing number of resuscitation room alerts in a resource-optimized manner.


Asunto(s)
Resucitación , Centros Traumatológicos , Humanos , Estudios Retrospectivos , Puntaje de Gravedad del Traumatismo , Cuidados Críticos
8.
J Clin Med ; 12(19)2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37834827

RESUMEN

INTRODUCTION: This study aimed to evaluate the utility of shear wave elastography (SWE) in assessing changes in deltoid muscle properties following reverse shoulder arthroplasty (RSA). METHODS: Our cohort consisted of 18 patients who underwent RSA due to various conditions, including osteoarthritis, cuff arthropathy, and irreducible proximal humeral fractures. Pre- and postoperative muscle elasticity and stiffness were measured using SWE and were compared with functional outcomes and radiological parameters. RESULTS: Our results showed significant changes in deltoid muscle elasticity after RSA, particularly in the anterior and middle portions. However, these alterations were not correlated with postoperative functional outcomes or specific radiological parameters. The study also underscored the potential of SWE for future applications, including the preoperative assessment of deltoid function, postoperative monitoring, and intraoperative use for optimal component positioning during RSA. CONCLUSION: Further research, involving larger, more homogeneous patient cohorts is needed to confirm these findings and to explore the potential influence of these changes on the biomechanical design of implants and prosthesis positioning in RSA.

9.
Clin Biomech (Bristol, Avon) ; 109: 106088, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37660575

RESUMEN

BACKGROUND: The use of polymethylmethacrylate cement for in-situ implant augmentation has considerable disadvantages: it is potentially cytotoxic, exothermic and non-degradable. Therefore, the primary aim of this study was to develop a magnesium phosphate cement which meets the requirements for in-situ implant augmentation as an alternative. Secondly, this experimental cement was compared to commercial bone cements in a biomechanical test set-up using augmented femoral head blades. METHODS: A total of 40 human femoral heads were obtained from patients who underwent total hip arthroplasty. After bone mineral density was quantified, specimens were assigned to four treatment groups. A blade of the Trochanteric Fixation Nail Advanced™ was inserted into each specimen and augmented with either Traumacem™ V+, Paste-CPC, the experimental magnesium phosphate cement or no cement. A rotational load-to-failure-test (0° to 90°) was performed. FINDINGS: A conventional two-component magnesium phosphate cement failed in-situ implant augmentation consistently due to filter pressing. Only a glycerol-based magnesium phosphate paste was suitable for the augmentation of femoral head blades. While the blades augmented with Traumacem™ V+ yielded the highest maximum torque overall (22.1 Nm), the blades augmented with Paste-CPC and the magnesium phosphate paste also showed higher maximum torque values (15.8 and 12.8 Nm) than the control group (10.8 Nm). INTERPRETATION: This study shows for the first time the development of a degradable magnesium phosphate cement paste which fulfills the requirements for in-situ implant augmentation. Simultaneously, a 48% increase in stability is demonstrated for a scenario where implant anchorage is difficult in osteoporotic bone.


Asunto(s)
Cementos para Huesos , Cabeza Femoral , Humanos , Cementos para Huesos/uso terapéutico , Cabeza Femoral/cirugía , Torque , Clavos Ortopédicos , Fenómenos Biomecánicos
10.
Arch Orthop Trauma Surg ; 143(10): 6251-6259, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37460845

RESUMEN

INTRODUCTION: Proximal ulna fractures with a large zone of comminution, such as in the context of Monteggia injuries, require mechanically strong osteosyntheses as they occur in regions with high physiological joint load. Consequently, implant failure and pseudarthrosis are critical and devastating complications, especially with the background of mainly young patients being affected. An effective solution could be provided by adding a small second plate 90° angulated to the standard dorsal plate in the area of non-union. Thus, this study investigates whether, from a biomechanical point of view, the use of such a mini or baby plate is worthwhile. MATERIALS AND METHODS: Comminuted fractures distal to the coronoid process, equivalent to Jupiter type IIb fractures, are generated on artificial Sawbones® of the ulna and stabilized using two different plate osteosyntheses: in the first group, a dorsal locking compression olecranon plate is used (LCP group). In the second group, a small, ulnar 5-hole olecranon plate is added as a baby plate in addition to the mother plate at the level of the fracture zone (MBP group). Dynamic biomechanical loading in degrees of flexion from 0° to 90° is carried out to determine yield load, stiffness, displacement, and changes in fracture gap width as well as bending of the dorsal plate. RESULTS: The "mother-baby-plate" osteosynthesis had a significantly higher yield load (p < 0.01) and stiffness (p = 0.01) than the LCP group. This correlates with the increased movement of the proximal fracture element during cyclic testing for the LCP group compared to the MBP group as measured by an optical metrology system. CONCLUSIONS: Here, we show evidence that the addition of a small plate to the standard plate is highly effective in increasing the biomechanical stability in severe fractures equivalent to Jupiter type IIb. As it hopefully minimizes complications like pseudarthrosis and implant failure and as the additional preparatory effort leading to compromised blood supply is regarded to be negligible, this justifies and highly advises the use of a mother-baby-plate system.


Asunto(s)
Fracturas Conminutas , Seudoartrosis , Fracturas del Cúbito , Femenino , Humanos , Madres , Fracturas del Cúbito/cirugía , Cúbito , Placas Óseas , Fijación Interna de Fracturas , Fracturas Conminutas/cirugía , Fenómenos Biomecánicos
11.
Trauma Case Rep ; 46: 100854, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37304217

RESUMEN

Background: Hyperextension fractures of the thoracolumbar spine are commonly seen in ankylotic disorders due to the rigidity of the spine. The known complications include instability, neurological deficits and posttraumatic deformity but there is no report of a hemodynamic relevant arterial bleeding in undisplaced hyperextension fractures. An arterial bleeding poses a life-threatening complication and may be difficult to recognize in an ambulatory or clinical setting. Case presentation: A 78-year-old male was brought to the emergency department after suffering a domestic fall with incapacitating lower back pain. X-rays and a CT scan revealed an undisplaced L2 hyperextension fracture which was treated conservatively. 9 days after admission, the patient complained about unprecedented abdominal pain with a CT scan disclosing a 12 × 9 × 20 cm retroperitoneal hematoma on grounds of an active arterial bleeding from a branch of the L2 lumbar artery. Subsequently, access via lumbotomy, evacuation of the hematoma and insertion of a hemostatic agent was performed. The therapy concept of the L2 fracture remained conservatively. Conclusions: A secondary, retroperitoneal arterial bleeding after a conservatively treated undisplaced hyperextension fracture of the lumbar spine is a rare and severe complication that has not been described in literature yet and may be difficult to recognize. An early CT scan is recommended in case of a sudden onset of abdominal pain in these fractures to fasten treatment and hence decrease morbidity and mortality. Thus, this case report contributes to the awareness of this complication in a spine fracture type with increasing incidence and clinical relevance.

12.
J Clin Med ; 12(11)2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37297997

RESUMEN

Traumatic brain injury (TBI) is the leading cause of death and disability in polytrauma and is often accompanied by concomitant injuries. We conducted a retrospective matched-pair analysis of data from a 10-year period from the multicenter database TraumaRegister DGU® to analyze the impact of a concomitant femoral fracture on the outcome of TBI patients. A total of 4508 patients with moderate to critical TBI were included and matched by severity of TBI, American Society of Anesthesiologists (ASA) risk classification, initial Glasgow Coma Scale (GCS), age, and sex. Patients who suffered combined TBI and femoral fracture showed increased mortality and worse outcome at the time of discharge, a higher chance of multi-organ failure, and a rate of neurosurgical intervention. Especially those with moderate TBI showed enhanced in-hospital mortality when presenting with a concomitant femoral fracture (p = 0.037). The choice of fracture treatment (damage control orthopedics vs. early total care) did not impact mortality. In summary, patients with combined TBI and femoral fracture have higher mortality, more in-hospital complications, an increased need for neurosurgical intervention, and inferior outcome compared to patients with TBI solely. More investigations are needed to decipher the pathophysiological consequences of a long-bone fracture on the outcome after TBI.

13.
Unfallchirurgie (Heidelb) ; 126(12): 952-959, 2023 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-36988660

RESUMEN

BACKGROUND: Contrary to the trend of decreasing traffic fatalities, the number of cyclists killed in Germany has been steadily increasing in recent years. With the increasing popularity of cycling in all age groups, the number of accidents with sometimes serious injuries is rising. In the course of this, the question arises what influence age has on the type and severity of injuries, the probability of survival and the length of hospital stay in seriously injured cyclists. METHODS: A retrospective analysis of data from the TraumaRegister DGU® (TR-DGU) from 2010 to 2019 was performed. All severely injured cyclists with a maximum abbreviated injury scale (MAIS) of 3+ (n = 14,651) in the TR-DGU were included in this study and the available parameters were evaluated. A subdivision into three age groups (60-69, 70-79, and ≥ 80 years) and a control group (20-59 years) was carried out. RESULTS: Injuries to the head were by far the most common, accounting for 64.2%. There was a marked increase in severe head injuries in the 60-plus years age group. Furthermore, with increasing age, the probability of prehospital intubation, catecholamine requirement, intensive care and hospital length of stay, and mortality increased. CONCLUSION: Head injuries represent the most common serious injury, especially among older cyclists. As helmet wearing was not recorded in the TraumaRegister DGU® during the evaluation period, no conclusion can be drawn about its effect. Furthermore, a higher age correlates with a longer hospital stay and a higher mortality, but does not represent an independent risk factor for death in severely injured patients.


Asunto(s)
Traumatismos Craneocerebrales , Traumatismo Múltiple , Humanos , Anciano de 80 o más Años , Estudios Transversales , Traumatismo Múltiple/epidemiología , Estudios Retrospectivos , Sistema de Registros
14.
Acad Radiol ; 30(7): 1358-1366, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36167629

RESUMEN

OBJECTIVES: Gantry-free cone-beam CT (CBCT) allows for comfortable patient positioning due to an open scanner architecture. Since CBCT without gantry is not yet established for clinical wrist trauma imaging, this study's aim was to investigate its diagnostic value in the preoperative workup of patients with distal radius and scaphoid fractures. METHODS: Within a 12-month period, 113 patients with severe wrist trauma underwent both radiography and CBCT with the same gantry-free multi-use scanner before surgery. Two radiologists retrospectively analyzed all datasets for the morphology of distal radius (n = 95) and scaphoid fractures (n = 20). In all 115 wrists (two bilateral injuries), surgical reports served as the standard of reference. RESULTS: While accuracy for distal radius fractures was comparable among CBCT and radiographs, the former was superior with regard to scaphoid fractures (Reader 1: 100.0% vs. 75.0%; Reader 2: 100.0% vs. 65.0%). Accuracy for multi-fragmentary radius injuries (100.0% vs. 90.5%; 100.0% vs. 93.7%), and articular affliction (99.0% vs. 84.2%; 100.0% vs. 83.2%) was also higher in CBCT. Regarding scaphoid fractures, CBCT proved superior for diagnosis of proximal pole or waist involvement (100.0% vs. 70.0%; 100.0% vs. 65.0%) and comminuted patterns (100.0% vs. 70.0%; 100.0% vs. 75.0%). Median effective dose of CBCT was as low as 3.65 µSv compared with 0.16 µSv for standard radiography. CONCLUSION: Gantry-free CBCT allows for excellent diagnostic accuracy in the assessment of distal radius and scaphoid fracture morphology. Even in patients with limited mobility, very low radiation dose is sufficient to maintain high image quality.


Asunto(s)
Fracturas Óseas , Hueso Escafoides , Humanos , Fracturas Óseas/diagnóstico por imagen , Radio (Anatomía) , Estudios Retrospectivos , Hueso Escafoides/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico
15.
Commun Med (Lond) ; 2(1): 164, 2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36550296

RESUMEN

BACKGROUND: Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage. METHODS: To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility. RESULTS: We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation. CONCLUSION: We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.


Life-threatening pelvic injuries are often associated with disruption of a joint within the hip bones, called the pubic symphysis. Disruption can lead to a gap and subsequent instability of the pelvis. The current treatment is to stabilize the joint with a steel plate and screws, however this often becomes unstable soon after the operation. In this study, we analyzed two alternatives for stabilization that use cables and clamps instead of the plate. Further, we tested a surgical approach for implantation. The cables and clamps were as stable as a steel plate so offer an alternative approach to stabilize the pubic symphysis.

16.
Sci Rep ; 12(1): 15481, 2022 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-36104462

RESUMEN

Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required.


Asunto(s)
Cementos para Huesos , Fracturas de la Tibia , Fenómenos Biomecánicos , Placas Óseas , Depresión , Fijación Interna de Fracturas/métodos , Humanos , Fracturas de la Tibia/cirugía
17.
Front Bioeng Biotechnol ; 10: 896790, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35992345

RESUMEN

The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.

18.
Oper Orthop Traumatol ; 34(5): 372-378, 2022 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-35644812

RESUMEN

OBJECTIVE: Soft tissue reconstruction of complex defects of the lower abdomen, groin, the perineum and the hip region present a reconstructive challenge. Besides free tissue transfer, pedicled flaps may also be utilized. Harvest of the vertical rectus abdominis flap causes a functional deficit by weakening the abdominal wall. Pedicled, perforator-based flaps minimize functional deficits by preserving muscle. INDICATIONS: Soft tissue defects with exposed vital structures, prosthetic devices or irradiated wound beds. CONTRAINDICATIONS: Previous surgery at the donor site, peripheral vascular disease at the pelvic and thigh region, previous vascular interventions at the donor site. SURGICAL TECHNIQUE: After preoperative localization of the perforators, a retrograde, intramuscular dissection of the pedicle allows sufficient length to be gained in order to transpose the flap into the defect. Tunneling of the flap beneath the rectus femoris muscle and Sartorius muscle is often required for tension-free inset. POSTOPERATIVE MANAGEMENT: Five days of bed-rest postoperatively followed by ambulation. RESULTS: No complete flap loss was encountered in 13 cases. In 2 cases a partial tip necrosis required secondary skin grafting.


Asunto(s)
Colgajo Perforante , Procedimientos de Cirugía Plástica , Ingle/cirugía , Humanos , Colgajo Perforante/cirugía , Perineo/cirugía , Colgajos Quirúrgicos , Muslo/cirugía , Resultado del Tratamiento
19.
BMC Musculoskelet Disord ; 23(1): 189, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35232415

RESUMEN

BACKGROUND: Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice. METHODS: Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers. RESULTS: In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676-0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525-0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771-0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692-0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912). CONCLUSIONS: The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.


Asunto(s)
Fracturas del Hombro , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Escápula/diagnóstico por imagen
20.
Eur J Trauma Emerg Surg ; 48(4): 3237-3242, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35128563

RESUMEN

PURPOSE: To evaluate the clinical benefit of surgical stabilization of rib fractures (SSRF) in polytrauma patients with serial rib fractures. METHODS: Retrospective single-center cohort analysis in trauma patients. Serial rib fracture was defined as three consecutive ribs confirmed by chest computer tomography (CT). Study cohort includes 243 patients that were treated conservatively and 34 patients that underwent SSRF. Demographic patient data, trauma mechanism, injury pattern, Injury Severity Score (ISS), Glasgow Coma Scale (GCS) and hospital course were analyzed. Two matched pair analyses stratified for ISS (32 pairs) and GCS (25 pairs) were performed. RESULTS: The majority of patients was male (74%) and aged 55 ± 20 years. Serial rib fractures were associated with more than 6 broken ribs in average (6.3 ± 3.7). Other thoracic bone injury included sternum (18%), scapula (16%) and clavicula (13%). Visceral injury consisted of pneumothorax (51%), lung contusion (33%) and diaphragmatic rupture (2%). Average ISS was 22 ± 7.3. Overall hospital stay was 15.9 and ICU stay 7.4 days. In hospital, mortality was 13%. SSRF did not improve hospital course or postoperative complications in the complete study cohort. However, patients with a significantly reduced GCS (7.6 ± 5.3 vs 11.22 ± 4.8; p = 0.006) benefitted from SSRF. Matched pair analysis stratified for GCS showed shorter ICU stays (9 vs 15 days; p = 0.005) including shorter respirator time (143 vs 305 h; p = 0.003). CONCLUSION: Patients with serial rib fractures and simultaneous moderate or severe traumatic brain injury benefit from surgical stabilization of rib fractures.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Fracturas de las Costillas , Traumatismos Torácicos , Lesiones Traumáticas del Encéfalo/complicaciones , Humanos , Puntaje de Gravedad del Traumatismo , Tiempo de Internación , Masculino , Estudios Retrospectivos , Fracturas de las Costillas/terapia , Traumatismos Torácicos/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA