Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Einstein (Sao Paulo) ; 21: eAO0418, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38126658

RESUMEN

OBJECTIVE: To establish the diagnostic performance of fine-needle aspiration in detecting benign and malignant neoplasm in comparison with post-thyroidectomy histopathological findings among patients who received a thyroidectomy. METHODS: Retrospective observational data collected between 2011-2021 were included from patients who received partial or total thyroidectomy. The Bethesda system was used to classify neoplasms from fine-needle aspiration procedures as benign or malignant. Sample characteristics, diagnostic accuracy, sensitivity, specificity, and predictive values were evaluated. RESULTS: Patients (n=360) who underwent thyroidectomy were analyzed, of whom 142 (39.4%) and 218 (60.6%) had benign and malignant neoplasms, respectively. Using the Bethesda system, 23 (6.4%) were classified as unsatisfactory result (BI), 83 (23.1%) as benign (BII), 50 (13.9%) as atypia of undetermined significance (BIII), 23 (6.4%) as suspected follicular or Hürthle cell neoplasia (BIV), 102 (28.3%) as suspected malignancy (BV) and 79 (21.9%) as malignant (BVI). The fine-needle aspiration diagnostic accuracy for carcinomas was 92%, while the sensitivity and specificity were 94.4% and 86.9%, respectively. The negative and positive predictive values were 87.9% and 93.9%, respectively. CONCLUSION: Fine-needle aspiration has high diagnostic accuracy, sensitivity and specificity, and is a reliable test for distinguishing between benign and malignant thyroid pathologies.


Asunto(s)
Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Biopsia con Aguja Fina , Estudios Retrospectivos , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/cirugía , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/diagnóstico , Nódulo Tiroideo/cirugía , Nódulo Tiroideo/patología
2.
Einstein (Säo Paulo) ; 21: eAO0418, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528568

RESUMEN

ABSTRACT Objective To establish the diagnostic performance of fine-needle aspiration in detecting benign and malignant neoplasm in comparison with post-thyroidectomy histopathological findings among patients who received a thyroidectomy. Methods Retrospective observational data collected between 2011-2021 were included from patients who received partial or total thyroidectomy. The Bethesda system was used to classify neoplasms from fine-needle aspiration procedures as benign or malignant. Sample characteristics, diagnostic accuracy, sensitivity, specificity, and predictive values were evaluated. Results Patients (n=360) who underwent thyroidectomy were analyzed, of whom 142 (39.4%) and 218 (60.6%) had benign and malignant neoplasms, respectively. Using the Bethesda system, 23 (6.4%) were classified as unsatisfactory result (BI), 83 (23.1%) as benign (BII), 50 (13.9%) as atypia of undetermined significance (BIII), 23 (6.4%) as suspected follicular or Hürthle cell neoplasia (BIV), 102 (28.3%) as suspected malignancy (BV) and 79 (21.9%) as malignant (BVI). The fine-needle aspiration diagnostic accuracy for carcinomas was 92%, while the sensitivity and specificity were 94.4% and 86.9%, respectively. The negative and positive predictive values were 87.9% and 93.9%, respectively. Conclusion Fine-needle aspiration has high diagnostic accuracy, sensitivity and specificity, and is a reliable test for distinguishing between benign and malignant thyroid pathologies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA