Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Synchrotron Radiat ; 29(Pt 4): 931-938, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787558

RESUMEN

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

3.
Sci Rep ; 11(1): 12883, 2021 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-34145307

RESUMEN

We present structure and equation of state (EOS) measurements of biaxially orientated polyethylene terephthalate (PET, [Formula: see text], also called mylar) shock-compressed to ([Formula: see text]) GPa and ([Formula: see text]) K using in situ X-ray diffraction, Doppler velocimetry, and optical pyrometry. Comparing to density functional theory molecular dynamics (DFT-MD) simulations, we find a highly correlated liquid at conditions differing from predictions by some equations of state tables, which underlines the influence of complex chemical interactions in this regime. EOS calculations from ab initio DFT-MD simulations and shock Hugoniot measurements of density, pressure and temperature confirm the discrepancy to these tables and present an experimentally benchmarked correction to the description of PET as an exemplary material to represent the mixture of light elements at planetary interior conditions.

4.
J Synchrotron Radiat ; 28(Pt 3): 688-706, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33949979

RESUMEN

The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.

6.
Rev Sci Instrum ; 92(1): 013101, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33514249

RESUMEN

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

7.
Phys Rev Lett ; 126(1): 015703, 2021 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-33480771

RESUMEN

We present results from the SPring-8 Angstrom Compact free electron LAser facility, where we used a high intensity (∼10^{20} W/cm^{2}) x-ray pump x-ray probe scheme to observe changes in the ionic structure of silicon induced by x-ray heating of the electrons. By avoiding Laue spots in the scattering signal from a single crystalline sample, we observe a rapid rise in diffuse scattering and a transition to a disordered, liquidlike state with a structure significantly different from liquid silicon. The disordering occurs within 100 fs of irradiation, a timescale that agrees well with first principles simulations, and is faster than that predicted by purely inertial behavior, suggesting that both the phase change and disordered state reached are dominated by Coulomb forces. This method is capable of observing liquid scattering without masking signal from the ambient solid, allowing the liquid structure to be measured throughout and beyond the phase change.

8.
BJOG ; 128(4): 745-754, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32783300

RESUMEN

OBJECTIVE: To assess psychosexual distress over a 12-month period among women receiving different human papillomavirus (HPV) and cytology results in the context of the English HPV primary screening pilot. DESIGN: Longitudinal, between-group study. SETTING: Five sites in England where primary HPV testing was piloted. POPULATION: Women aged 24-65 years (n = 1133) who had taken part in the NHS Cervical Screening Programme. METHODS: Women were sent a postal questionnaire soon after receiving their screening results (baseline) and 6 and 12 months later. Data were analysed using linear regression models to compare psychosexual outcomes between groups receiving six possible combinations of HPV and cytology screening results, including a control group with normal cytology and no HPV test. MAIN OUTCOME MEASURES: Psychosexual distress, assessed using six items from the Psychosocial Effects of Abnormal Pap Smears Questionnaire (PEAPS-Q). RESULTS: At all time points, there was an association between screening result group and psychosexual distress (all P < 0.001). At baseline, mean psychosexual distress score (possible range: 1-5) was significantly higher among women with HPV and normal cytology (B = 1.15, 95% CI 0.96-1.34), HPV and abnormal cytology (B = 1.02, 95% CI: 0.78-1.27) and persistent HPV (B = 0.90, 95% CI 0.70-1.10) compared with the control group (all P < 0.001). At the 6 and 12 month follow ups the pattern of results were similar, but coefficients were smaller. CONCLUSIONS: Our findings suggest receiving an HPV-positive result can cause psychosexual distress, particularly in the short-term. Developing interventions to minimise the psychosexual burden of testing HPV-positive will be essential to avoid unnecessary harm to the millions of women taking part in cervical screening. TWEETABLE ABSTRACT: Receiving an HPV-positive result following primary HPV testing can cause psychosexual distress, particularly in the short-term.


Asunto(s)
Detección Precoz del Cáncer/psicología , Infecciones por Papillomavirus/diagnóstico , Salud Sexual , Estrés Psicológico/etiología , Neoplasias del Cuello Uterino/diagnóstico , Frotis Vaginal/psicología , Adulto , Anciano , Estudios de Casos y Controles , Detección Precoz del Cáncer/efectos adversos , Detección Precoz del Cáncer/métodos , Femenino , Estudios de Seguimiento , Encuestas de Atención de la Salud , Humanos , Modelos Lineales , Persona de Mediana Edad , Infecciones por Papillomavirus/complicaciones , Infecciones por Papillomavirus/psicología , Estrés Psicológico/diagnóstico , Estrés Psicológico/epidemiología , Neoplasias del Cuello Uterino/psicología , Neoplasias del Cuello Uterino/virología , Frotis Vaginal/efectos adversos
9.
Sci Rep ; 10(1): 14564, 2020 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-32884061

RESUMEN

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within [Formula: see text] for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

10.
J Struct Biol ; 212(1): 107584, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32736074

RESUMEN

It is shown how serial block-face electron microscopy (SBEM) of insulin-secreting ß-cells in wild-type mouse pancreatic islets of Langerhans can be used to determine maturation times of secretory granules. Although SBEM captures the ß-cell structure at a snapshot in time, the observed ultrastructure can be considered representative of a dynamic equilibrium state of the cells since the pancreatic islets are maintained in culture in approximate homeostasis. It was found that 7.2 ± 1.2% (±st. dev.) of the ß-cell volume is composed of secretory granule dense-cores exhibiting angular shapes surrounded by wide (typically ≳100 nm) electron-lucent halos. These organelles are identified as mature granules that store insulin for regulated release through the plasma membrane, with a release time of 96 ± 12 h, as previously obtained from pulsed 35S-radiolabeling of cysteine and methionine. Analysis of ß-cell 3D volumes reveals a subpopulation of secretory organelles without electron-lucent halos, identified as immature secretory granules. Another subpopulation of secretory granules is found with thin (typically ≲30 nm) electron-lucent halos, which are attributed to immature granules that are transforming from proinsulin to insulin by action of prohormone convertases. From the volume ratio of proinsulin in the immature granules to insulin in the mature granules, we estimate that the newly formed immature granules remain in morphologically-defined immature states for an average time of 135 ± 14 min, and the immature transforming granules for an average time of 130 ± 17 min.


Asunto(s)
Células Secretoras de Insulina/metabolismo , Islotes Pancreáticos/metabolismo , Vesículas Secretoras/metabolismo , Animales , Transporte Biológico/fisiología , Membrana Celular/metabolismo , Gránulos Citoplasmáticos/metabolismo , Insulina/metabolismo , Masculino , Ratones , Microscopía Electrónica/métodos
11.
Sci Rep ; 10(1): 13172, 2020 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32764631

RESUMEN

Laser compression has long been used as a method to study solids at high pressure. This is commonly achieved by sandwiching a sample between two diamond anvils and using a ramped laser pulse to slowly compress the sample, while keeping it cool enough to stay below the melt curve. We demonstrate a different approach, using a multilayer 'ring-up' target whereby laser-ablation pressure compresses Pb up to 150 GPa while keeping it solid, over two times as high in pressure than where it would shock melt on the Hugoniot. We find that the efficiency of this approach compares favourably with the commonly used diamond sandwich technique and could be important for new facilities located at XFELs and synchrotrons which often have higher repetition rate, lower energy lasers which limits the achievable pressures that can be reached.

12.
Phys Rev Lett ; 124(22): 225002, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32567902

RESUMEN

The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperature-dependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order of the Fermi energy. Plasma heating and opacity enhancement are observed on ultrafast timescales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm dense matter.

13.
Nat Commun ; 11(1): 2620, 2020 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-32457297

RESUMEN

The gas and ice giants in our solar system can be seen as a natural laboratory for the physics of highly compressed matter at temperatures up to thousands of kelvins. In turn, our understanding of their structure and evolution depends critically on our ability to model such matter. One key aspect is the miscibility of the elements in their interiors. Here, we demonstrate the feasibility of X-ray Thomson scattering to quantify the degree of species separation in a 1:1 carbon-hydrogen mixture at a pressure of ~150 GPa and a temperature of ~5000 K. Our measurements provide absolute values of the structure factor that encodes the microscopic arrangement of the particles. From these data, we find a lower limit of [Formula: see text]% of the carbon atoms forming isolated carbon clusters. In principle, this procedure can be employed for investigating the miscibility behaviour of any binary mixture at the high-pressure environment of planetary interiors, in particular, for non-crystalline samples where it is difficult to obtain conclusive results from X-ray diffraction. Moreover, this method will enable unprecedented measurements of mixing/demixing kinetics in dense plasma environments, e.g., induced by chemistry or hydrodynamic instabilities.

14.
Rev Sci Instrum ; 90(6): 065114, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31255042

RESUMEN

Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.

15.
Sci Rep ; 9(1): 4196, 2019 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-30862904

RESUMEN

We investigated the high-pressure behavior of polyethylene (CH2) by probing dynamically-compressed samples with X-ray diffraction. At pressures up to 200 GPa, comparable to those present inside icy giant planets (Uranus, Neptune), shock-compressed polyethylene retains a polymer crystal structure, from which we infer the presence of significant covalent bonding. The A2/m structure which we observe has previously been seen at significantly lower pressures, and the equation of state measured agrees with our findings. This result appears to contrast with recent data from shock-compressed polystyrene (CH) at higher temperatures, which demonstrated demixing and recrystallization into a diamond lattice, implying the breaking of the original chemical bonds. As such chemical processes have significant implications for the structure and energy transfer within ice giants, our results highlight the need for a deeper understanding of the chemistry of high pressure hydrocarbons, and the importance of better constraining planetary temperature profiles.

16.
J Appl Anim Welf Sci ; 22(3): 207-218, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29695170

RESUMEN

Rabbits are commonly kept in a variety of settings, including homes, laboratories, and veterinary clinics. Despite the popularity of keeping this prey species, little research has investigated current methods of handling. The aim of this study was to examine the experience of caregivers (owners and keepers) in using five handling methods commonly referred to in books written for companion animal (pet) owners and veterinary and/or laboratory personnel. An online survey was completed by 2644 respondents, representing all three of these groups, and breeders. Data were acquired to determine sources that participants used to gain knowledge of different handling methods, the methods they used and for what purposes they used them, and their perceptions of any associated difficulties or welfare concerns. Results indicated that participants most frequently used the method of supporting a rabbit's body against a person's chest, which was considered the easiest and most welfare-friendly method of the handling methods explored. "Scruffing with rear support" was the least used method and was considered to be distressing and painful for the rabbit. As rabbits are a terrestrial prey species, being picked up is likely an innately stressful experience. Additional research is encouraged to explore the experience of rabbits during handling to identify methods that can be easily used with the fewest welfare compromises.


Asunto(s)
Crianza de Animales Domésticos/métodos , Bienestar del Animal , Conejos , Adolescente , Adulto , Animales , Femenino , Humanos , Irlanda , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios , Reino Unido
17.
Rev Sci Instrum ; 89(10): 10F104, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30399942

RESUMEN

We describe a setup for performing inelastic X-ray scattering and X-ray diffraction measurements at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. This technique is capable of performing high-, meV-resolution measurements of dynamic ion features in both crystalline and non-crystalline materials. A four-bounce silicon (533) monochromator was used in conjunction with three silicon (533) diced crystal analyzers to provide an energy resolution of ∼50 meV over a range of ∼500 meV in single shot measurements. In addition to the instrument resolution function, we demonstrate the measurement of longitudinal acoustic phonon modes in polycrystalline diamond. Furthermore, this setup may be combined with the high intensity laser drivers available at MEC to create warm dense matter and subsequently measure ion acoustic modes.

18.
J Struct Biol ; 202(3): 216-228, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29408702

RESUMEN

Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50-100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach.


Asunto(s)
Plaquetas/ultraestructura , Tomografía con Microscopio Electrónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Electrónica de Transmisión de Rastreo/métodos , Humanos , Imagenología Tridimensional/métodos
20.
Phys Rev Lett ; 121(24): 245501, 2018 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-30608736

RESUMEN

We present results for the ionic structure in hydrocarbons (polystyrene, polyethylene) that were shock compressed to pressures of up to 190 GPa, inducing rapid melting of the samples. The structure of the resulting liquid is then probed using in situ diffraction by an x-ray free electron laser beam, demonstrating the capability to obtain reliable diffraction data in a single shot, even for low-Z samples without long range order. The data agree well with ab initio simulations, validating the ability of such approaches to model mixed samples in states where complex interparticle bonds remain, and showing that simpler models are not necessarily valid. While the results clearly exclude the possibility of complete carbon-hydrogen demixing at the conditions probed, they also, in contrast to previous predictions, indicate that diffraction is not always a sufficient diagnostic for this phenomenon.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA