Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rofo ; 188(4): 374-80, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27002498

RESUMEN

PURPOSE: Paclitaxel-coated balloons (PCB) inhibit neointimal proliferation in arteries. The purpose of this retrospective analysis was to investigate the effect of PCB in in-stent restenosis after transjugular intrahepatic portosystemic shunt (TIPS) in patients with cirrhotic liver disease. MATERIALS AND METHODS: Six patients (mean age: 65 ±â€Š10 years) with recurrent in-stent restenoses in TIPS (5 bare stents, 1 covered stent) underwent a single percutaneous transluminal angioplasty (PTA) with PCB (3 µg paclitaxel/mm(2)). Post-interventional outcome and patency were compared with those of prior plain optimal balloon angioplasty (POBA) in the same patients. During a two-year follow-up period, all patients underwent angiographic examinations at 6-month intervals. In-stent minimal lumen diameter (MLD) and late lumen loss (LLL) were assessed. Paclitaxel residues on balloon and sheath surfaces as well as venous plasma concentrations (0 - 24 hours) were analyzed. RESULTS: PCB decreased the need for clinically driven repeat PTA (POBA: 53 % of angiographic examinations; paclitaxel PTA: 19 %; P = 0.014). LLL/diameter stenosis was higher after POBA (2.4 ±â€Š1.5 mm/28 ±â€Š18 %) than after PCB (0.5 ±â€Š0.8 mm/7 ±â€Š11 %, P = 0.029). Residual paclitaxel on balloons was 28 ±â€Š9 % of dose and 0.2 ±â€Š0.1 % on sheath surfaces. Paclitaxel plasma concentrations were below detectable levels throughout the first 24 hours after the interventions in all patients. The procedure was well tolerated and no clinical side effects attributable to paclitaxel were observed. CONCLUSION: In patients with recurrent in-stent stenoses, a single PTA with PCB resulted in a prolonged secondary patency due to pseudointimahyperplasia without a systemic effect of paclitaxel. KEY POINTS: •Intimahyperplasia is a common reason for long-time TIPS dysfunction. •First-in-man local paclitaxel application in TIPS patients with recurrent in-stent stenoses. •PTA with PCB resulted in a prolonged secondary patency compared to POBA. •No systemic effects of Paclitaxel were detected.


Asunto(s)
Angioplastia de Balón/métodos , Stents Liberadores de Fármacos , Fibrosis/terapia , Oclusión de Injerto Vascular/terapia , Paclitaxel/administración & dosificación , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Anciano , Angioplastia de Balón/instrumentación , Terapia Combinada/métodos , Femenino , Fibrosis/complicaciones , Fibrosis/diagnóstico , Oclusión de Injerto Vascular/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Moduladores de Tubulina/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA