Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Nucl Med Rev Cent East Eur ; 7(1): 31-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15318308

RESUMEN

BACKGROUND: The aim of this study was to present and compare the results of proposed methods for optimal red cell mass and plasma volume (RCM&PV) estimation, and their influence on the interpretation of obtained results. MATERIAL AND METHODS: In 120/280 patients with polycythaemia rubra vera, subjected to RCM&PV determination with autologous erythrocytes in vitro labelled with 51Cr-sodium chromate, optimal volumes were determined using: 1. traditional ml/kg of: --the real body weight method (ml/kg RBW); --the optimal body weight method (ml/kg OBW). 2. the body weight, height, and sex based method (Retzlaff's tables), 3. the method recommended by the International Council for Standardization in Haematology (ICSH), based on body surface area. RESULTS: Different interpretation of the same results of 120 RCM&PV measurements was registered in 48/120 patients (40%). The greatest disagreement existed between ml/kg RBW and ml/kg OBW methods (in 39/120 subjects, 32.5%). In underweight patients the ml/kg RBW method, and in overweight patients the ml/kg OBW method, offered better agreement with ICSH&Retzlaff's methods. The ml/kg RBW method disagreed with ICSH&Retzlaff's methods and ml/kg OBW in 25% and 19.2% of patients respectively. ICSH and Retzlaff's methods disagreed in 10/120 patients (8.3%). The ICSH method yielded significantly lower optimal volumes than Retzlaff's. CONCLUSION: Three methods for optimal RCM&PV estimation lead to different interpretations of the same results of RCM&PV measurements with 51Cr-erythrocytes in 40% of patients. Two ml/kg body weight methods show greater disagreement in comparison with ICSH and Retzlaff's methods, which differ significantly. The ICSH method yields lower optimal values compared to Retzlaff's.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Eritrocitos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Volumen Plasmático , Plasma/diagnóstico por imagen , Policitemia Vera/sangre , Policitemia Vera/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Determinación del Volumen Sanguíneo/normas , Composición Corporal , Cromatos/sangre , Guías como Asunto , Humanos , Interpretación de Imagen Asistida por Computador/normas , Marcaje Isotópico/métodos , Persona de Mediana Edad , Policitemia Vera/fisiopatología , Cintigrafía , Radiofármacos/sangre , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Compuestos de Sodio/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA