Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(11)2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38893697

RESUMEN

CBCT (cone beam computed tomography) is an imaging investigation that provides three-dimensional (3D) images of craniofacial structures. The purpose of this study is to determine the mechanical behavior of an orthodontic system where the lingual treatment technique was used in a 25-year-old female patient from whom a set of CBCT scans was used. CBCT images were processed through software programs such as Invesalius, Geomagic, and Solid Works, to create models containing virtual solids. These models were then imported into Ansys Workbench 2019 R3 (a finite element method software program) for successive simulations to generate displacement maps, deformations, stress distributions, and diagrams. We observed that in the lingual technique, the lowest force occurring on the maxillary teeth is at 1.1, while the highest force appears at 2.3. In the mandible, the lowest force occurs at 4.6, and the highest force at 3.1. The values of the forces and the results of the finite element method can represent a basis for the innovation of new orthodontic springs and also of bracket elements. Thus, by using new technologies, orthodontic practice can be significantly improved for the benefit of patients. Other virtual methods and techniques can be used in future studies, including the application of virtual reality for orthodontic diagnosis.

2.
J Funct Biomater ; 15(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38667542

RESUMEN

This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research. Methods: A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student's t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM. Conclusions: The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.

3.
J Clin Med ; 12(6)2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36983129

RESUMEN

The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann-Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = -2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA