Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Talanta ; 281: 126803, 2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39255624

RESUMEN

Lactate dehydrogenase (LDH), a prevalent enzyme involved in anaerobic glycolysis, is released into body fluids following cell damage and has long been a general marker of tissue injury. However, due to its lack of selectivity and the advent of more accurate biomarkers, the clinical utility of LDH has been largely limited to confirming hemolysis. LDH has been recognized as a valuable prognostic biomarker for various cancers, making its monitoring crucial during cancer management. Traditional LDH methods include spectrophotometric analysis of NADH at 340 nm, native electrophoresis, or enzyme-linked immunosorbent assay. This study presents the first lateral flow immunoassay (LFIA) for the smartphone-based quantification of serum LDH levels at the point of care. Highly-affinity and specific antibodies have been produced, with 5 nM equilibrium dissociation constant and no cross-reactivity with human serum albumin and human immunoglobulin G. Utilizing carbon nanoparticles as signal transducers significantly enhanced the quantification limit 55-fold, compared to the conventional gold nanoparticles-based LFIA, achieving a quantification limit of 1.5 ng mL-1. The developed assay demonstrated a mean recovery rate of 115 ± 21 % when evaluating LDH-spiked serum samples. This method can be an interesting home-testing tool for monitoring cancer progression or therapy effectiveness.

2.
ACS Appl Mater Interfaces ; 16(36): 48187-48202, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39186609

RESUMEN

The development and optimization of holographic materials represent a great challenge today. These materials must be synthesized according to the characteristics that are desirable in photonic devices whose application is the object of investigation. In certain holographic sensors and biosensors, it is essential that the recording material be stable in liquid media. Furthermore, the holographic gratings stored in them must have temporal and structural stability, so that they can act as transducers of the analytical signal. Therefore, it is essential to optimize its storage in terms of the chemical composition of the material and the optical parameters of recording. This work focuses on the study of the storage optimization of unslanted transmission volume phase holograms in photohydrogels based on acrylamide and N,N'-methylenebis(acrylamide). Hydrogel matrices, also composed of acrylamide and N,N'-methylenebis(acrylamide), with different degrees of cross-linking were used and analyzed by scanning electron microscopy and UV-visible spectroscopy. The best results in terms of diffraction efficiency were reached for hydrogel matrices with an acrylamide/N,N'-methylenebis(acrylamide) molar ratio between 19.9 and 26. This relationship was also optimized in the incubator solution used to incorporate the components necessary for the formation of the holograms in the hydrogel matrices. The maximum diffraction efficiency, about 35%, was achieved when using an incubation solution with an acrylamide/N,N'-methylenebis(acrylamide) molar ratio of 4.35. The influence of the physical thickness of the hydrogel layers, the intensity, and the exposure time on the diffraction efficiency was also investigated and optimized. In addition, the behavior of the hologram was analyzed after a washing stage with PBST. A simple model that considered the effects of bending and attenuation of holographic gratings was proposed and used to obtain the optical parameters of the holograms.

3.
Talanta ; 278: 126511, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38986307

RESUMEN

The application of advances in personalized medicine requires the support of in vitro diagnostic techniques aimed at the accurate, fast, sensitive, and precise determination of selected biomarkers. Herein, a novel optical centrifugal microfluidic device is developed for clinical analysis and point-of-care diagnostics. Based on compact disc technology, the integrated biophotonic system enables multiple immunoassays in miniaturized mode. The disposable microfluidic discs are made in cyclic olefin copolymer (COP), containing arrays of immobilized probes. In the developed approach, up to six patient samples can each be tested simultaneously. A portable instrument (<2 kg) controls the assay and the high-sensitive reproducible optical detection in transmission mode. Also, the instrument incorporates specific functionalities for personalized telemedicine. The device (analytical method, disc platform, reader, and software) has been validated to diagnose IgE-mediated drug allergies, such as amoxicillin and penicillin G. The total and specific IgE to ß-lactam antibiotics were determined in human serum from patients (25 µL). The excellent analytical performances (detection limit 0.24 ng/mL, standard deviation 7-20 %) demonstrated that the developed system could have the potential for a broader impact beyond the allergy field, as it applies to other IVD tests.


Asunto(s)
Biomarcadores , Inmunoglobulina E , Humanos , Biomarcadores/sangre , Inmunoglobulina E/sangre , Inmunoensayo/métodos , Dispositivos Laboratorio en un Chip , Límite de Detección , Hipersensibilidad a las Drogas/diagnóstico , Hipersensibilidad a las Drogas/sangre , Técnicas Analíticas Microfluídicas/instrumentación , Amoxicilina/sangre
4.
Talanta ; 279: 126563, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39032462

RESUMEN

This work describes the development of a label-free (LF) biosensing platform for the direct detection of targets based on diffractive structures fabricated with acrylamide-based hydrogels biofunctionalized with proteins and antibodies. Hydrogels containing Bovine Serum Albumin protein (BSA) with different crosslinking degrees were synthesized and characterized to find the optimal conditions for the suitable fabrication of surface relief gratings (SRGs). The bioavailability of BSA-functionalized hydrogels for the specific recognition of anti-BSA antibodies was verified by fluorescence detection. After the hydrogel-based SRG fabrication, diffraction efficiency measures at two different laser wavelengths were used for the direct LF detection of anti-BSA antibodies. The limit of detection in the sub mg L-1 range was read. Additionally, SRGs were prepared with hydrogels biofunctionalized with anti-rabbit antibodies for the direct detection of IgGs from rabbit serum, obtaining similar analytical performance without the necessity of labeling or applying amplification strategies.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Inmunoglobulina G , Albúmina Sérica Bovina , Hidrogeles/química , Técnicas Biosensibles/métodos , Albúmina Sérica Bovina/química , Animales , Conejos , Inmunoglobulina G/sangre , Holografía , Propiedades de Superficie , Bovinos , Límite de Detección
5.
EXCLI J ; 23: 888-903, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38983778

RESUMEN

The coexistence within a subcellular complex of inter-cellular proteins Ro60, responsible for preserving ncRNA quality, and Ro52, involved in intracellular proteolysis, has been a subject of ongoing debate. Employing molecular docking in tandem with experimental methods like Quartz Crystal Microbalance with Dissipation (QCM-D), Proximity Ligation Assay (PLA), and Indirect Immunofluorescence (IIF), we reveal the presence of Ro60 associating with Ro52 within the cytoplasm. This result unveils the formation of a weak transient complex with a Ka ≈ (3.7 ± 0.3) x 106 M-1, where the toroid-shaped Ro60 structure interacts with the Ro52's Fc receptor, aligning horizontally within the PRY-SPRY domains of the Ro52's homodimer. The stability of this complex relies on the interaction between Ro52 chain A and specific Ro60 residues, such as K133, W177, or L185, vital in the Ro60-YRNA bond. These findings bridge the role of Ro60 in YRNA management with Ro52's function in intracellular proteolysis, emphasizing the potential impact of transient complexes on cellular pathways. See also the graphical abstract(Fig. 1).

6.
Anal Bioanal Chem ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38922434

RESUMEN

The biosensor, named "virusmeter" in this study, integrates quartz crystal microbalance technology with an immune-functionalized chip to distinguish between symptomatic patients with respiratory diseases and healthy individuals by analyzing exhaled air samples. Renowned for its compact design, rapidity, and noninvasive nature, this device yields results within a 5-min timeframe. Evaluated under controlled conditions with 54 hospitalized symptomatic COVID-19 patients and 128 control subjects, the biosensor demonstrated good overall sensitivity (98.15%, 95% CI 90.1-100.0) and specificity (96.87%, 95% CI 92.2-99.1). This proof-of-concept presents an innovative approach with significant potential for leveraging piezoelectric sensors to diagnose respiratory diseases.

7.
Biosens Bioelectron ; 251: 116131, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38367566

RESUMEN

Plant health monitoring is devised as a new concept to elucidate in situ physiological processes. The need for increased food production to nourish the growing global population is inconsistent with the dramatic impact of climate change, which hinders crop health and exacerbates plant stress. In this context, wearable sensors play a crucial role in assessing plant stress. Herein, we present a low-cost 3D-printed hollow microneedle array (HMA) patch as a sampling device coupled with biosensors based on screen-printing technology, leading to affordable analysis of biomarkers in the plant fluid of a leaf. First, a refinement of the 3D-printing method showed a tip diameter of 25.9 ± 3.7 µm with a side hole diameter on the microneedle of 228.2 ± 18.6 µm using an affordable 3D printer (<500 EUR). Notably, the HMA patch withstanded the forces exerted by thumb pressing (i.e. 20-40 N). Subsequently, the holes of the HMA enabled the fluid extraction tested in vitro and in vivo in plant leaves (i.e. 13.5 ± 1.1 µL). A paper-based sampling strategy adapted to the HMA allowed the collection of plant fluid. Finally, integrating the sampling device onto biosensors facilitated the in situ electrochemical analysis of plant health biomarkers (i.e. H2O2, glucose, and pH) and the electrochemical profiling of plants in five plant species. Overall, this electrochemical platform advances precise and versatile sensors for plant health monitoring. The wearable device can potentially improve precision farming practices, addressing the critical need for sustainable and resilient agriculture in changing environmental conditions.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Peróxido de Hidrógeno , Impresión Tridimensional , Biomarcadores
8.
Mikrochim Acta ; 191(1): 63, 2023 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-38157073

RESUMEN

The incorporation of biomacromolecules onto silicon waveguiding microstructures constitutes a growing trend that pushes towards compact and miniaturized biosensing systems. This paper presents the integration of one-dimensional periodic nanostructures of proteins on the surface of micrometric silicon waveguides for transducing binding events between biomacromolecules. The study demonstrates this new bioanalytical principle by experimental results and theoretical calculations, and proves that rib waveguides (1--1.6-µm width) together with protein gratings (495--515-nm period) display suitable spectral responses for this optical biosensing system. Protein assemblies of bovine serum albumin are fabricated on the surface of silicon nitride waveguides, characterized by electron microscopy, and their response is measured by optical frequency domain reflectometry along the fabrication process and the subsequent stages of the biorecognition assays. Detection and quantification limits of 0.3 and 3.7 µg·mL-1, respectively, of specific antibodies are inferred from experimental dose-response curves. Among other interesting features, the results of this study point towards new miniaturized and integrated sensors for label-free bioanalysis.


Asunto(s)
Técnicas Biosensibles , Nanoestructuras , Dispositivos Ópticos , Técnicas Biosensibles/métodos , Nanoestructuras/química , Albúmina Sérica Bovina
9.
Dalton Trans ; 52(48): 18464-18472, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38013493

RESUMEN

Colloidal lead halide perovskite nanocrystals are highly luminescent materials with great promise as fluorescent probes in biosensing as long as their intrinsic instability in aqueous media is effectively addressed. In this study, we successfully prepared stable and multicolored CsPbX3@SiO2 (X = Cl/Br, Br and I) core-shell nanoparticles through a simple method based on the water-induced transformation of Cs4PbX6 into CsPbX3, combined with sol-gel procedures. We observed that the concentration of the Cs4PbX6 precursor plays a crucial role in the formation of isolated nanospheres with uniform silica coating and in controlling the number of core-free particles. Furthermore, our research expands this approach to other halide compositions, resulting in multicolored core-shell nanoparticles with emission wavelengths ranging from 490 to 700 nm, average sizes below 30 nm, and photoluminescence quantum yields close to 60%. Unlike in previous reports, the silica coating boosts the photoluminescence quantum yields compared to uncoated counterparts and provides increased structural stability for more than four days. Moreover, a controlled thermal treatment confers water stability to the as-synthesized nanoparticles. To establish the feasibility of the developed materials as fluorescent probes, we successfully demonstrated their specific recognition of a humanized antibody (omalizumab) used in treating patients with severe allergic asthma. This work paves the way to develop in vitro tests using CsPbX3@SiO2 core-shell nanoparticles as fluorogenic probes.


Asunto(s)
Nanosferas , Agua , Humanos , Agua/química , Colorantes Fluorescentes , Dióxido de Silicio/química , Luminiscencia
10.
Gels ; 9(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37754391

RESUMEN

The role of volume hydrogel holographic gratings as optical transducers in sensor devices for point-of-care applications is increasing due to their ability to be functionalized for achieving enhanced selectivity. The first step in the development of these transducers is the optimization of the holographic recording process. The optimization aims at achieving gratings with reproducible diffraction efficiency, which remains stable after reiterative washings, typically required when working with analytes of a biological nature or several step tests. The recording process of volume phase transmission gratings within Acrylamide/Propargyl Acrylate hydrogel layers reported in this work was successfully performed, and the obtained diffraction gratings were optically characterized. Unslanted volume transmission gratings were recorded in the hydrogel layers diffraction efficiencies; up to 80% were achieved. Additionally, the recorded gratings demonstrated stability in water after multiple washing steps. The hydrogels, after functionalization with oligonucleotide probes, yields a specific hybridization response, recognizing the complementary strand as demonstrated by fluorescence. Analyte-sensitive hydrogel layers with holographic structures are a promising candidate for the next generation of in vitro diagnostic tests.

11.
Anal Chem ; 95(32): 12113-12121, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37545056

RESUMEN

The global prevalence of ß-lactam allergy poses a major challenge in administering first-line antibiotics, such as penicillins, to a significant portion of the population. The lack of ß-lactam IgE antibody pools with defined selectivity hampers the standardization and validation of in vitro assays for ß-lactam allergy testing. To address this limitation, this study introduces a synthetic IgE specific to ß-lactam antibiotics as a valuable tool for drug allergy research and diagnostic tests. Using phage display technology, we constructed a library of human single-chain antibody fragments (scFv) to target the primary determinant of amoxicillin, a widely used ß-lactam antibiotic. Subsequently, we produced a complete human synthetic IgE molecule using the highly efficient baculovirus expression vector system. This synthetic IgE molecule served as a standard in an in vitro chemiluminescence immunoassay for ß-lactam antibiotic allergy testing. Our results demonstrated a detection limit of 0.05 IU/mL (0.63 pM), excellent specificity (100%), and a four-fold higher clinical sensitivity (73%) compared to the in vitro reference assay when testing a cohort of 150 serum samples. These findings have significant implications for reliable interlaboratory comparison studies, accurate labeling of allergic patients, and combating the global public health threat of antimicrobial resistance. Furthermore, by serving as a valuable trueness control material, the synthetic IgE facilitates the standardization of diagnostic tests for ß-lactam allergy and demonstrates the potential of utilizing this synthetic strategy as a promising approach for generating reference materials in drug allergy research and diagnostics.


Asunto(s)
Hipersensibilidad a las Drogas , Hipersensibilidad , Humanos , Pruebas Cutáneas , Antibacterianos , beta-Lactamas , Penicilinas , Hipersensibilidad a las Drogas/diagnóstico , Hipersensibilidad a las Drogas/epidemiología , Monobactamas , Antibióticos Betalactámicos , Inmunoglobulina E
12.
Anal Chim Acta ; 1265: 341343, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37230582

RESUMEN

In the context of personalized and cost-effective treatment, knowledge of the mutational status of specific genes is advantageous to predict which patients are responsive to therapies. As an alternative to one-by-one detection or massive sequencing, the presented genotyping tool determines multiple polymorphic sequences that vary a single nucleotide. The biosensing method includes an effective enrichment of mutant variants and selective recognition by colorimetric DNA arrays. The proposed approach is the hybridization between sequence-tailored probes and products from PCR with SuperSelective primers to discriminate specific variants in a single locus. A fluorescence scanner, a documental scanner, or a smartphone captured the chip images to obtain spot intensities. Hence, specific recognition patterns identified any single-nucleotide change in the wild-type sequence overcoming qPCR methods and other array-based approaches. Studied mutational analyses applied to human cell lines provided high discrimination factors, the precision was 95%, and the sensitivity was 1% mutant of total DNA. Also, the methods showed a selective genotyping of the KRAS gene from tumorous samples (tissue and liquid biopsy), corroborating results by NGS. The developed technology supported on low-cost robust chips and optical reading provides an attractive pathway toward implementing fast, cheap, reproducible discrimination of oncological patients.


Asunto(s)
ADN , Nucleótidos , Humanos , Hibridación de Ácido Nucleico , Análisis de Secuencia por Matrices de Oligonucleótidos , ADN/genética , Mutación
13.
Trends Biotechnol ; 41(10): 1299-1313, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37150668

RESUMEN

In order to decentralize health care, the development of point-of-care (PoC) assays has gained significant attention in recent decades. The lateral flow immunoassay (LFIA) has emerged as a promising bioanalytical method due to its low cost and single-step detection process. However, its limited sensitivity and inability to detect disease biomarkers at clinically relevant levels have hindered its application for early diagnosis. This review explores the potential of merging different electrokinetic phenomena into paper-based assays to enhance their analytical performance, offering a versatile and affordable approach for PoC testing. The review exposes the challenges faced in integrating electrokinetic phenomena with paper-based biosensing and concludes by discussing the issues that need to be improved to maximize the potential of this technology for early diagnosis.


Asunto(s)
Técnicas Biosensibles , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Inmunoensayo/métodos , Tecnología , Técnicas Biosensibles/métodos
14.
Mikrochim Acta ; 190(5): 166, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-37010667

RESUMEN

A high percentage of the population suffers from multiple food allergies justifying  the importance of reliable diagnostic methods. Single-analyte solutions based on the determination of specific immunoglobulins E (sIgE) are safe and fast but are generally time-consuming and expensive. Thus sustainable microanalytical methods that provide multianalyte profiling information are highly demanded. This work presents the in vitro biosensing of specific IgE levels based on a reversed-phase allergen array. The approach consists of optical biosensing supported by direct multiplex immunoassays and on-disc technology. It identifies 12 sIgE associated with food allergies in a single analysis with a low serum sample volume (25 µL). After processing captured images, specific signals for each target biomarker correlate to their concentration. The assay analytically performs well with 0.3 IU/mL and 0.41 IU/mL as the detection and quantification limits in serum, respectively. This novel method achieves excellent clinical specificity (100%) and high sensitivity (91.1%), considering the diagnosis obtained by clinical history and ImmunoCAP analysis. The results demonstrate that microanalytical systems based on allergen arrays can potentially diagnose multiple food allergies and are easily implemented in primary care laboratory settings.


Asunto(s)
Alérgenos , Hipersensibilidad a los Alimentos , Humanos , Hipersensibilidad a los Alimentos/diagnóstico , Inmunoensayo/métodos , Análisis por Micromatrices , Inmunoglobulina E
15.
Biosensors (Basel) ; 13(3)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36979524

RESUMEN

The present research is focused on the development of a biofunctionalized hydrogel with a surface diffractive micropattern as a label-free biosensing platform. The biosensors described in this paper were fabricated with a holographic recording of polyethylene terephthalate (PET) surface micro-structures, which were then transferred into a hydrogel material. Acrylamide-based hydrogels were obtained with free radical polymerization, and propargyl acrylate was added as a comonomer, which allowed for covalent immobilization of thiolated oligonucleotide probes into the hydrogel network, via thiol-yne photoclick chemistry. The comonomer was shown to significantly contribute to the immobilization of the probes based on fluorescence imaging. Two different immobilization approaches were demonstrated: during or after hydrogel synthesis. The second approach showed better loading capacity of the bioreceptor groups. Diffraction efficiency measurements of hydrogel gratings at 532 nm showed a selective response reaching a limit of detection in the complementary DNA strand of 2.47 µM. The label-free biosensor as designed could significantly contribute to direct and accurate analysis in medical diagnosis as it is cheap, easy to fabricate, and works without the need for further reagents.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Hidrogeles/química , Hibridación de Ácido Nucleico/métodos , Técnicas Biosensibles/métodos
16.
Biosensors (Basel) ; 13(2)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36831980

RESUMEN

This paper focuses on creating one-dimensional diffractive grooved structures of antigen proteins on glass substrates for the label-free detection of antibodies to dairy allergens. In particular, the fabrication of protein structures is carried out by combining microcontact printing with physisorption, imines coupling, and thiol-ene click chemistry. The work first sets up these patterning methods and discusses and compares the main aspects involved in them (structure, biolayer thickness, functionality, stability). Homogeneous periodic submicron structures of proteins are created and characterized by diffractive measurements, AFM, FESEM, and fluorescence scanning. Then, this patterning method is applied to proteins involved in cow milk allergy, and the resulting structures are implemented as optical transducers to sense specific immunoglobulins G. In particular, gratings of bovine serum albumin, casein, and ß-lactoglobulin are created and assessed, reaching limits of detection in the range of 30-45 ng·mL-1 of unlabeled antibodies by diffractive biosensing.


Asunto(s)
Hipersensibilidad a la Leche , Animales , Femenino , Bovinos , Inmunoglobulina E , Alérgenos , Caseínas , Albúmina Sérica Bovina/química
17.
Food Chem ; 404(Pt A): 134570, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36252370

RESUMEN

The hypothesis of this study is centered around the logic that an enhanced analysis of potential allergens during the food production can lead to increased accuracy and reliability of food labeling. The development of a cost-effective and straightforward optoelectrical microanalytical system for the simultaneous quantification of the six most common food allergens (peanut, hazelnut, almond, milk, wheat, and soybean) is presented. The system uses a regular versatile disc (DVD) functionalized with highly selective antibodies in a microarray format and a DVD drive as the optical detector. The multiplexed assay reliably (RSD < 20 %) determines the level of the allergenic proteins ranging from 0.1 to 143.4 ng mL-1. The analysis of food consumables (biscuits, seafood substitutes, and probiotic foods) revealed a 100 % accuracy in identifying the allergens ingredients declared on the label. The method offers potential for application as a high throughput biosensing tool for screening multiple allergens in commercial foods.


Asunto(s)
Corylus , Hipersensibilidad a los Alimentos , Niño , Humanos , Alérgenos/análisis , Reproducibilidad de los Resultados , Arachis
18.
Biosensors (Basel) ; 12(11)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36354489

RESUMEN

Quality assurance and food safety are of great concern within the food industry because of unknown quantities of allergens often present in food. Therefore, there is an ongoing need to develop rapid, sensitive, and easy to use methods that serve as an alternative to mass spectrometry and enzyme-linked immunosorbent assay (ELISA) for monitoring food safety. Lateral flow immunoassay is one of the most used point-of-need devices for clinical, environmental, and food safety applications. Compared to traditional methods, it appears to be a simple and fast alternative for detecting food allergens. However, its reliability is frequently questioned due to the lack of quantitative information. In this study, a lateral flow microimmunoassay (LFµIA) is presented that integrates up to 36 spots in microarray format in a single strip, providing semi-quantitative information about the level of allergens, positive and negative controls, internal calibration, and hook effect. The LFµIA has been evaluated for the on-site simultaneous and reliable quantification of almond and peanut allergens as a proof of concept, demonstrating high sensitivity (185 and 229 µg/kg, respectively), selectivity (77%), and accuracy (RSD 5-25%) when analyzing commercial allergen-suspicious food consumables.


Asunto(s)
Alérgenos , Hipersensibilidad a los Alimentos , Humanos , Alérgenos/análisis , Reproducibilidad de los Resultados , Alimentos , Inmunoensayo/métodos , Ensayo de Inmunoadsorción Enzimática/métodos
19.
ACS Appl Mater Interfaces ; 14(36): 41640-41648, 2022 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36047566

RESUMEN

The nanostructuration of biolayers has become a paradigm for exploiting nanoscopic light-matter phenomena for biosensing, among other biomedical purposes. In this work, we present a photopatterning method to create periodic structures of biomacromolecules based on a local and periodic mild denaturation of protein biolayers mediated by UV-laser irradiation. These nanostructures are constituted by a periodic modulation of the protein activity, so they are free of topographic and compositional changes along the pattern. Herein, we introduce the approach, explore the patterning parameters, characterize the resulting structures, and assess their overall homogeneity. This UV-based patterning principle has proven to be an easy, cost-effective, and fast way to fabricate large areas of homogeneous one-dimensional protein patterns (2 min, 15 × 1.2 mm, relative standard deviation ≃ 16%). This work also investigates the implementation of these protein patterns as transducers for diffractive biosensing. Using a model immunoassay, these patterns have demonstrated negligible signal contributions from non-specific bindings and comparable experimental limits of detection in buffer media and in human serum (53 and 36 ng·mL-1 of unlabeled IgG, respectively).


Asunto(s)
Técnicas Biosensibles , Nanoestructuras , Fenómenos Biofísicos , Humanos , Inmunoensayo/métodos , Rayos Láser , Nanoestructuras/química , Transductores
20.
Biosens Bioelectron ; 213: 114454, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35696866

RESUMEN

The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 µL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98-100%) and specificity (84-98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Gripe Humana , Infecciones del Sistema Respiratorio , Antígenos Virales/análisis , COVID-19/diagnóstico , Humanos , Gripe Humana/diagnóstico , Pandemias , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Infecciones del Sistema Respiratorio/diagnóstico , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA