Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
1.
AIP Adv ; 14(8): 085109, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39130131

RESUMEN

Scalable electronic brain implants with long-term stability and low biological perturbation are crucial technologies for high-quality brain-machine interfaces that can seamlessly access delicate and hard-to-reach regions of the brain. Here, we created "NeuroRoots," a biomimetic multi-channel implant with similar dimensions (7 µm wide and 1.5 µm thick), mechanical compliance, and spatial distribution as axons in the brain. Unlike planar shank implants, these devices consist of a number of individual electrode "roots," each tendril independent from the other. A simple microscale delivery approach based on commercially available apparatus minimally perturbs existing neural architectures during surgery. NeuroRoots enables high density single unit recording from the cerebellum in vitro and in vivo. NeuroRoots also reliably recorded action potentials in various brain regions for at least 7 weeks during behavioral experiments in freely-moving rats, without adjustment of electrode position. This minimally invasive axon-like implant design is an important step toward improving the integration and stability of brain-machine interfacing.

2.
J Mater Chem B ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189156

RESUMEN

Neurological conditions such as epilepsy can have a significant impact on people's lives. Here, we discuss a new perspective for the study/treatment of these conditions using photopharmacology. A multimodal, intracranial implant that incorporates fluidic channels for localised drug delivery, electrodes for recording and stimulation, and a light source for photoswitching is used for in vivo administration and deactivation of a photoresponsive AMPA antagonist. We review current advancements in the relevant disciplines and show experimentally that the inhibition of seizure-like events induced in the hippocampus by electrical stimulation can be altered upon switching the drug with light. We discuss the interconnection of the drug's photopharmacological properties with the design of the device by modelling light penetration into the rat brain with Monte Carlo simulations. This work delivers a new perspective, including initial experimental and computational efforts on in vivo photopharmacology to understand and eventually treat neurological conditions.

3.
Nat Commun ; 15(1): 7523, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39214981

RESUMEN

Implantable devices interfacing with peripheral nerves exhibit limited longevity and resolution. Poor nerve-electrode interface quality, invasive surgical placement and development of foreign body reaction combine to limit research and clinical application of these devices. Here, we develop cuff implants with a conformable design that achieve high-quality and stable interfacing with nerves in chronic implantation scenarios. When implanted in sensorimotor nerves of the arm in awake rats for 21 days, the devices record nerve action potentials with fascicle-specific resolution and extract from these the conduction velocity and direction of propagation. The cuffs exhibit high biocompatibility, producing lower levels of fibrotic scarring than clinically equivalent PDMS silicone cuffs. In addition to recording nerve activity, the devices are able to modulate nerve activity at sub-nerve resolution to produce a wide range of paw movements. When used in a partial nerve ligation rodent model, the cuffs identify and characterise changes in nerve C fibre activity associated with the development of neuropathic pain in freely-moving animals. The developed implantable devices represent a platform enabling new forms of fine nerve signal sensing and modulation, with applications in physiology research and closed-loop therapeutics.


Asunto(s)
Potenciales de Acción , Nervios Periféricos , Animales , Nervios Periféricos/fisiología , Ratas , Potenciales de Acción/fisiología , Masculino , Electrodos Implantados , Neuralgia/fisiopatología , Neuralgia/terapia , Ratas Sprague-Dawley , Prótesis e Implantes , Conducción Nerviosa/fisiología
4.
Bioelectron Med ; 10(1): 19, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39164790

RESUMEN

Bioelectronic Medicine (BEM), which uses implantable electronic medical devices to interface with electrically active tissues, aspires to revolutionize the way we understand and fight disease. By leveraging knowledge from microelectronics, materials science, information technology, neuroscience and medicine, BEM promises to offer novel solutions that address unmet clinical needs and change the concept of therapeutics. This perspective communicates our vision for the future of BEM and presents the necessary steps that need to be taken and the challenges that need to be faced before this new technology can flourish.

5.
Nat Electron ; 7(7): 586-597, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086869

RESUMEN

The functional and sensory augmentation of living structures, such as human skin and plant epidermis, with electronics can be used to create platforms for health management and environmental monitoring. Ideally, such bioelectronic interfaces should not obstruct the inherent sensations and physiological changes of their hosts. The full life cycle of the interfaces should also be designed to minimize their environmental footprint. Here we report imperceptible augmentation of living systems through in situ tethering of organic bioelectronic fibres. Using an orbital spinning technique, substrate-free and open fibre networks-which are based on poly (3,4-ethylenedioxythiophene):polystyrene sulfonate-can be tethered to biological surfaces, including fingertips, chick embryos and plants. We use customizable fibre networks to create on-skin electrodes that can record electrocardiogram and electromyography signals, skin-gated organic electrochemical transistors and augmented touch and plant interfaces. We also show that the fibres can be used to couple prefabricated microelectronics and electronic textiles, and that the fibres can be repaired, upgraded and recycled.

6.
MRS Commun ; 14(3): 261-266, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38966401

RESUMEN

Microelectrode arrays (MEAs) have applications in drug discovery, toxicology, and basic research. They measure the electrophysiological response of tissue cultures to quantify changes upon exposure to biochemical stimuli. Unfortunately, manual addition of chemicals introduces significant noise in the recordings. Here, we report a simple-to-fabricate fluidic system that addresses this issue. We show that cell cultures can be successfully established in the fluidic compartment under continuous flow conditions and that the addition of chemicals introduces minimal noise in the recordings. This dynamic cell culture system represents an improvement over traditional tissue culture wells used in MEAs, facilitating electrophysiology measurements.

7.
ACS Appl Mater Interfaces ; 16(28): 36727-36734, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-38972069

RESUMEN

Understanding the dynamics of ion migration and volume change is crucial to studying the functionality and long-term stability of soft polymeric materials operating at liquid interfaces, but the subsurface characterization of swelling processes in these systems remains elusive. In this work, we address the issue using modulated electrochemical atomic force microscopy as a depth-sensitive technique to study electroswelling effects in the high-performance actuator material polypyrrole doped with dodecylbenzenesulfonate (Ppy:DBS). We perform multidimensional measurements combining local electroswelling and electrochemical impedance spectroscopies on microstructured Ppy:DBS actuators. We interpret charge accumulation in the polymeric matrix with a quantitative model, giving access to both the spatiotemporal dynamics of ion migration and the distribution of electroswelling in the electroactive polymer layer. The findings demonstrate a nonuniform distribution of the effective ionic volume in the Ppy:DBS layer depending on the film morphology and redox state. Our findings indicate that the highly efficient actuation performance of Ppy:DBS is caused by rearrangements of the polymer microstructure induced by charge accumulation in the soft polymeric matrix, increasing the effective ionic volume in the bulk of the electroactive film for up to two times the value measured in free water.

8.
Nat Commun ; 15(1): 6290, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060241

RESUMEN

Electrocorticography is an established neural interfacing technique wherein an array of electrodes enables large-area recording from the cortical surface. Electrocorticography is commonly used for seizure mapping however the implantation of large-area electrocorticography arrays is a highly invasive procedure, requiring a craniotomy larger than the implant area to place the device. In this work, flexible thin-film electrode arrays are combined with concepts from soft robotics, to realize a large-area electrocorticography device that can change shape via integrated fluidic actuators. We show that the 32-electrode device can be packaged using origami-inspired folding into a compressed state and implanted through a small burr-hole craniotomy, then expanded on the surface of the brain for large-area cortical coverage. The implantation, expansion, and recording functionality of the device is confirmed in-vitro and in porcine in-vivo models. The integration of shape actuation into neural implants provides a clinically viable pathway to realize large-area neural interfaces via minimally invasive surgical techniques.


Asunto(s)
Electrocorticografía , Electrodos Implantados , Electrocorticografía/instrumentación , Electrocorticografía/métodos , Animales , Porcinos , Craneotomía/métodos , Craneotomía/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Robótica/instrumentación , Robótica/métodos , Encéfalo/fisiología
9.
Sci Adv ; 10(29): eadn5142, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39018406

RESUMEN

Recent progress in the development of synthetic polymer networks has enabled the next generation of hydrogel-based machines and devices. The ability to mimic the mechanical and electrical properties of human tissue gives great potential toward the fields of bioelectronics and soft robotics. However, fabricating hydrogel devices that display high ionic conductivity while maintaining high stretchability and softness remains unmet. Here, we synthesize supramolecular poly(ionic) networks, which display high stretchability (>1500%), compressibility (>90%), and rapid self-recovery (<30 s), while achieving ionic conductivities of up to 0.1 S cm -1. Dynamic cross-links give rise to inter-layer adhesion and a stable interface is formed on account of ultrahigh binding affinities (>1013 M-2). Superior adherence between layers enabled the fabrication of an intrinsically stretchable hydrogel power source, paving the way for the next generation of multi-layer tissue mimetic devices.

10.
Sci Adv ; 10(26): eado9576, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38924408

RESUMEN

Lip language recognition urgently needs wearable and easy-to-use interfaces for interference-free and high-fidelity lip-reading acquisition and to develop accompanying data-efficient decoder-modeling methods. Existing solutions suffer from unreliable lip reading, are data hungry, and exhibit poor generalization. Here, we propose a wearable lip language decoding technology that enables interference-free and high-fidelity acquisition of lip movements and data-efficient recognition of fluent lip language based on wearable motion capture and continuous lip speech movement reconstruction. The method allows us to artificially generate any wanted continuous speech datasets from a very limited corpus of word samples from users. By using these artificial datasets to train the decoder, we achieve an average accuracy of 92.0% across individuals (n = 7) for actual continuous and fluent lip speech recognition for 93 English sentences, even observing no training burn on users because all training datasets are artificially generated. Our method greatly minimizes users' training/learning load and presents a data-efficient and easy-to-use paradigm for lip language recognition.


Asunto(s)
Habla , Dispositivos Electrónicos Vestibles , Humanos , Lenguaje , Labio/fisiología , Movimiento , Masculino , Femenino , Adulto , Lectura de los Labios , Captura de Movimiento
11.
Sci Adv ; 10(19): eadl1230, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38718109

RESUMEN

The spinal cord is crucial for transmitting motor and sensory information between the brain and peripheral systems. Spinal cord injuries can lead to severe consequences, including paralysis and autonomic dysfunction. We introduce thin-film, flexible electronics for circumferential interfacing with the spinal cord. This method enables simultaneous recording and stimulation of dorsal, lateral, and ventral tracts with a single device. Our findings include successful motor and sensory signal capture and elicitation in anesthetized rats, a proof-of-concept closed-loop system for bridging complete spinal cord injuries, and device safety verification in freely moving rodents. Moreover, we demonstrate potential for human application through a cadaver model. This method sees a clear route to the clinic by using materials and surgical practices that mitigate risk during implantation and preserve cord integrity.


Asunto(s)
Traumatismos de la Médula Espinal , Médula Espinal , Animales , Médula Espinal/fisiología , Ratas , Traumatismos de la Médula Espinal/terapia , Traumatismos de la Médula Espinal/fisiopatología , Humanos , Estimulación Eléctrica/métodos , Electrodos Implantados
12.
Biomaterials ; 310: 122624, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38805956

RESUMEN

The proliferation of medical wearables necessitates the development of novel electrodes for cutaneous electrophysiology. In this work, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) is combined with a deep eutectic solvent (DES) and polyethylene glycol diacrylate (PEGDA) to develop printable and biocompatible electrodes for long-term cutaneous electrophysiology recordings. The impact of printing parameters on the conducting properties, morphological characteristics, mechanical stability and biocompatibility of the material were investigated. The optimised eutectogel formulations were fabricated in four different patterns -flat, pyramidal, striped and wavy- to explore the influence of electrode geometry on skin conformability and mechanical contact. These electrodes were employed for impedance and forearm EMG measurements. Furthermore, arrays of twenty electrodes were embedded into a textile and used to generate body surface potential maps (BSPMs) of the forearm, where different finger movements were recorded and analysed. Finally, BSPMs for three different letters (B, I, O) in sign-language were recorded and used to train a logistic regressor classifier able to reliably identify each letter. This novel cutaneous electrode fabrication approach offers new opportunities for long-term electrophysiological recordings, online sign-language translation and brain-machine interfaces.


Asunto(s)
Electrodos , Aprendizaje Automático , Poliestirenos , Impresión Tridimensional , Textiles , Humanos , Poliestirenos/química , Conductividad Eléctrica , Dispositivos Electrónicos Vestibles , Compuestos Bicíclicos Heterocíclicos con Puentes/química , Geles/química , Polímeros/química , Polietilenglicoles/química , Electromiografía/métodos , Materiales Biocompatibles/química
13.
Nat Mater ; 23(7): 969-976, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38671159

RESUMEN

Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.


Asunto(s)
Microelectrodos , Nervios Periféricos , Animales , Ratas , Nervios Periféricos/fisiología , Nervio Ciático/fisiología , Ratas Sprague-Dawley , Técnicas Electroquímicas/métodos
14.
Adv Mater ; 36(19): e2312735, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38290128

RESUMEN

Devices interfacing with biological tissues can provide valuable insights into function, disease, and metabolism through electrical and mechanical signals. However, certain neuromuscular tissues, like those in the gastrointestinal tract, undergo significant strains of up to 40%. Conventional inextensible devices cannot capture the dynamic responses in these tissues. This study introduces electrodes made from poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and polydimethylsiloxane (PDMS) that enable simultaneous monitoring of electrical and mechanical responses of gut tissue. The soft PDMS layers conform to tissue surfaces during gastrointestinal movement. Dopants, including Capstone FS-30 and polyethylene glycol, are explored to enhance the conductivity, electrical sensitivity to strain, and stability of the PEDOT:PSS. The devices are fabricated using shadow masks and solution-processing techniques, providing a faster and simpler process than traditional clean-room-based lithography. Tested on ex vivo mouse colon and human stomach, the device recorded voltage changes of up to 300 µV during contraction and distension consistent with muscle activity, while simultaneously recording resistance changes of up to 150% due to mechanical strain. These devices detect and respond to chemical stimulants and blockers, and can induce contractions through electrical stimulation. They hold great potential for studying and treating complex disorders like irritable bowel syndrome and gastroparesis.


Asunto(s)
Dimetilpolisiloxanos , Poliestirenos , Animales , Ratones , Poliestirenos/química , Humanos , Dimetilpolisiloxanos/química , Contracción Muscular/fisiología , Electrodos , Tracto Gastrointestinal/fisiología , Estómago/fisiología , Colon/fisiología , Conductividad Eléctrica , Polímeros/química , Fenómenos Electrofisiológicos , Compuestos Bicíclicos Heterocíclicos con Puentes/química , Compuestos Bicíclicos Heterocíclicos con Puentes/farmacología , Tiofenos/química , Tiofenos/farmacología
15.
Adv Sci (Weinh) ; 11(27): e2306424, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38251224

RESUMEN

In this work, a new method of multi-material printing in one-go using a commercially available 3D printer is presented. The approach is simple and versatile, allowing the manufacturing of multi-material layered or multi-material printing in the same layer. To the best of the knowledge, it is the first time that 3D printed Poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) micro-patterns combining different materials are reported, overcoming mechanical stability issues. Moreover, the conducting ink is engineered to obtain stable in-time materials while retaining sub-100 µm resolution. Micro-structured bio-shaped protuberances are designed and 3D printed as electrodes for electrophysiology. Moreover, these microstructures are combined with polymerizable deep eutectic solvents (polyDES) as functional additives, gaining adhesion and ionic conductivity. As a result of the novel electrodes, low skin impedance values showed suitable performance for electromyography recording on the forearm. Finally, this concluded that the use of polyDES conferred stability over time, allowing the usability of the electrode 90 days after fabrication without losing its performance. All in all, this demonstrated a very easy-to-make procedure that allows printing PEDOT:PSS on soft, hard, and/or flexible functional substrates, opening up a new paradigm in the manufacturing of conducting multi-functional materials for the field of bioelectronics and wearables.

16.
Proc Natl Acad Sci U S A ; 121(4): e2320855121, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38232285
17.
ACS Mater Lett ; 5(12): 3340-3346, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38075386

RESUMEN

Underwater recording remains a critical challenge in bioelectronics because traditional flexible electrodes can not fulfill essential requirements such as stability and steady conductivity in aquatic environments. Herein, we show the use of elastic gels made of hydrophobic natural eutectic solvents as water-resistant electrodes. These eutectogels are designed with tailorable mechanical properties via one-step photopolymerization of acrylic monomers in different eutectic mixtures composed of fatty acids and menthol. The low viscosity of the eutectics turns the formulations into suitable inks for 3D printing, allowing fast manufacturing of complex objects. Furthermore, the hydrophobic nature of the building blocks endows the eutectogels with excellent stability and low water uptake. The obtained flexible eutectogel electrodes can record real-time electromyography (EMG) signals with low interference in the air and underwater.

18.
Biomaterials ; 303: 122393, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37977006

RESUMEN

Spinal cord injuries have devastating consequences for humans, as mammalian neurons of the central nervous system (CNS) cannot regenerate. In the peripheral nervous system (PNS), however, neurons may regenerate to restore lost function following injury. While mammalian CNS tissue softens after injury, how PNS tissue mechanics changes in response to mechanical trauma is currently poorly understood. Here we characterised mechanical rat nerve tissue properties before and after in vivo crush and transection injuries using atomic force microscopy-based indentation measurements. Unlike CNS tissue, PNS tissue significantly stiffened after both types of tissue damage. This nerve tissue stiffening strongly correlated with an increase in collagen I levels. Schwann cells, which crucially support PNS regeneration, became more motile and proliferative on stiffer substrates in vitro, suggesting that changes in tissue stiffness may play a key role in facilitating or impeding nervous system regeneration.


Asunto(s)
Tejido Nervioso , Traumatismos de la Médula Espinal , Humanos , Ratas , Animales , Sistema Nervioso Central , Células de Schwann/fisiología , Neuronas , Regeneración Nerviosa/fisiología , Axones/fisiología , Mamíferos
19.
Nanoscale ; 15(37): 15304-15317, 2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37682040

RESUMEN

Identification of non-amplified DNA sequences and single-base mutations is essential for molecular biology and genetic diagnostics. This paper reports a novel sensor consisting of electrochemically-gated graphene coplanar waveguides coupled with a microfluidic channel. Upon exposure to analytes, propagation of electromagnetic waves in the waveguides is modified as a result of interactions with the fringing field and modulation of graphene dynamic conductivity resulting from electrostatic gating. Probe DNA sequences are immobilised on the graphene surface, and the sensor is exposed to DNA sequences which either perfectly match the probe, contain a single-base mismatch or are unrelated. By monitoring the scattering parameters at frequencies between 50 MHz and 50 GHz, unambiguous and reproducible discrimination of the different strands is achieved at concentrations as low as one attomole per litre (1 aM). By controlling and synchronising frequency sweeps, electrochemical gating, and liquid flow in the microfluidic channel, the sensor generates multidimensional datasets. Advanced data analysis techniques are utilised to take full advantage of the richness of the dataset. A classification accuracy >97% between all three sequences is achieved using different Machine Learning models, even in the presence of simulated noise and low signal-to-noise ratios. The sensor exceeds state-of-the-art sensitivity of field-effect transistors and microwave sensors for the identification of single-base mismatches.


Asunto(s)
Técnicas Biosensibles , Grafito , Grafito/química , Microondas , Técnicas Biosensibles/métodos , Sondas de ADN/química , Relación Señal-Ruido
20.
Sci Adv ; 9(35): eadi3536, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37647402

RESUMEN

Organic mixed ionic-electronic conductors (OMIECs) directly convert between ionic and electronic charge through electrochemical (de)doping, enabling a wide range of applications in bioelectronics, neuromorphic computing, and energy storage and conversion. While both ionic and electronic transport are individually well characterized, their combined transport has been difficult to describe self-consistently. We use in situ measurements of electrochemical (de)doping of an archetypal OMIEC to inform a quasi-field drift-diffusion model, which accurately captures experimentally measured ion transport across a range of potentials. We find that the chemical potential of holes, which is modulated by changes in doping level, represents a major driving force for mixed charge transport. Using numerical simulations at device-relevant time scales and potentials, we find that the competition between hole drift and diffusion leads to diffuse space charge regions despite high charge densities. This effect is unique to mixed conducting systems where mobile ionic charges can compensate the accumulation or depletion of electronic charge, thereby screening electrostatic driving forces.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA