Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IUCrJ ; 11(Pt 4): 519-527, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727170

RESUMEN

A new polymorph of 1,3-diacetylpyrene has been obtained from its melt and thoroughly characterized using single-crystal X-ray diffraction, steady-state UV-Vis spectroscopy and periodic density functional theory calculations. Experimental studies covered the temperature range from 90 to 390 K and the pressure range from atmospheric to 4.08 GPa. Optimal sample placement in a diamond anvil cell according to our previously presented methodology ensured over 80% data coverage up to 0.8 Šfor a monoclinic sample. Unrestrained Hirshfeld atom refinement of the high-pressure crystal structures was successful and anharmonic behavior of carbonyl oxygen atoms was observed. Unlike the previously characterized polymorph, the structure of 2°AP-ß is based on infinite π-stacks of antiparallel 2°AP molecules. 2°AP-ß displays piezochromism and piezofluorochromism which are directly related to the variation in interplanar distances within the π-stacking. The importance of weak intermolecular interactions is reflected in the substantial negative thermal expansion coefficient of -55.8 (57) MK-1 in the direction of C-H...O interactions.

2.
IUCrJ ; 8(Pt 6): 1006-1017, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34804552

RESUMEN

Sufficiently high completeness of diffraction data is necessary to correctly determine the space group, observe solid-state structural transformations or investigate charge density distribution under pressure. Regrettably, experiments performed at high pressure in a diamond anvil cell (DAC) yield inherently incomplete datasets. The present work systematizes the combined influence of radiation wavelength, DAC opening angle and sample orientation in a DAC on the completeness of diffraction data collected in a single-crystal high-pressure (HP) experiment with the help of dedicated software. In particular, the impact of the sample orientation on the achievable data completeness is quantified and proved to be substantial. Graphical guides for estimating the most beneficial sample orientation depending on the sample Laue class and assuming a few commonly used experimental setups are proposed. The usefulness of these guides has been tested in the case of luminescent 1,3-diacetylpyrene, suspected to undergo transitions from the α phase (Pnma) to the γ phase (Pn21 a) and δ phase (P1121/a) under pressure. Effective sample orientation has ensured over 90% coverage even for the monoclinic system and enabled unrestrained structure refinements and access to complete systematic extinction patterns.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA