Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(1): e14232, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38088260

RESUMEN

PURPOSE: This study aims to assess the accuracy of a modified electron beam calibration based on the IAEA TRS-398 and AAPM-TG-51 in multicenter radiotherapy. METHODS: This study was performed using the Elekta and Varian Linear Accelerator electron beams with energies of 4-22 MeV under reference conditions using cylindrical (PTW 30013, IBA FC65-G, and IBA FC65-P) and parallel-plate (PTW 34045, PTW 34001, and IBA PPC-40) chambers. The modified calibration used a cylindrical chamber and an updated k ' Q $k{^{\prime}}_Q$ based on Monte Carlo calculations, whereas TRS-398 and TG-51 used cylindrical and parallel-plate chambers for reference dosimetry. The dose ratio of the modified calibration procedure, TRS-398 and TG-51 were obtained by comparing the dose at the maximum depth of the modified calibration to TRS-398 and TG-51. RESULTS: The study found that all cylindrical chambers' beam quality conversion factors determined with the modified calibration ( k ' Q ) $( {{{k^{\prime}}}_Q} )$ to the TRS-398 and TG-51 vary from 0.994 to 1.003 and 1.000 to 1.010, respectively. The dose ratio of modified/TRS-398cyl and modified/TRS-398parallel-plate, the variation ranges were 0.980-1.014 and 0.981-1.019, while for the counterpart modified/TG-51cyl was found varying between 0.991 and 1.017 and the ratio of modified/TG-51parallel-plate varied in the range of 0.981-1.019. CONCLUSION: This multi-institutional study analyzed a modified calibration procedure utilizing new data for electron beam calibrations at multiple institutions and evaluated existing calibration protocols. Based on observed variations, the current calibration protocols should be updated with detailed metrics on the stability of linac components.


Asunto(s)
Electrones , Fenilpropionatos , Radioterapia de Alta Energía , Humanos , Radioterapia de Alta Energía/métodos , Calibración , Agua , Radiometría/métodos , Fotones
2.
J Appl Clin Med Phys ; 23(4): e13573, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35226389

RESUMEN

PURPOSE: The recently worldwide standard measurement of electron beam reference dosimetry include the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 and Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocols. Muir et al. have modified calibration methods for electron beam calibration based on AAPM TG-51. They found that the use of cylindrical chambers at low energy gave acceptable results. In this study, we propose and report a modified calibration for electron beam based on IAEA TRS-398, the standard reference dosimetry protocol worldwide. METHODS: This work was carried out with energies of 6, 8, 10, 12, and 15 MeV. The electron beam is generated from Elektra Synergy Platform and Versa HD linear accelerator. The charge readings were measured with PTW 30013, IBA CC13, Exradin A1Sl, and Exradin A11 chambers connected to the electrometer. The dose calculation uses an equation of modified calibration for electron beam using the updated k Q ${k_Q}$ factor in previous work. The absorbed dose to water for electron beam is expressed in dose per monitor unit (cGy/MU). Thus, we compared dose per monitor unit (D/MU) calculation using a modified calibration to TRS-398. RESULTS: In this work, we have succeeded in implementing the modified calibration of electron beam based on TRS-398 by applying a cylindrical chamber in all energy beams and using the updated k Q ${k_Q}$ factor. The ratio of the absorbed dose to water between original and modified calibration protocols of TRS-398 (Dw ) for the cylindrical chamber was 1.002 on the Elekta Synergy Platform and 1.000 on the Versa HD while for the parallel-plate chamber it was 1.013 on the Elekta Synergy Platform and 1.014 on the Versa HD. Based on these results, both the cylindrical and parallel-plate chambers are still within the tolerance limit allowed by the TRS-398 protocol, which is ±2%. Therefore, modified calibration based on TRS-398 gives acceptable results and is simpler to use clinically.


Asunto(s)
Energía Nuclear , Fotones , Calibración , Electrones , Humanos , Radiometría/métodos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA