Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Monit Comput ; 24(2): 155-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20229061

RESUMEN

INTRODUCTION: Thoracic electrical bioimpedance (TEB) for measuring cardiac output (CO) is being explored increasingly as an alternative to pulmonary artery catheter. The major advantage of this technology is that it is non-invasive and easy to perform. Several studies have compared it to thermodilution cardiac output using PA catheter, with variable correlation. Multigated radionuclide equilibrium cardiography (RNEC) method of cardiac output measurement is known to be reliable. OBJECTIVE: To compare cardiac output measured by thoracic electrical bioimpdenace with that measured by multigated radionuclide equilibrium cardiography. PATIENTS AND METHODS: CO studies were performed sequentially at a single sitting by TEB and RNEC methods among patients with cardiac symptoms referred for radionuclide study as part of their evaluation. TEB CO was measured by placing two pairs of electrodes on either side of neck and two other pairs on either side of the lower chest. Stroke volume was estimated from the sequential changes in transthoracic electrical bioimpedance induced by rhythmic aortic blood flow, using Kubicek equation. RNEC-CO was measured by intravenous injection of radio-active Technitium-tagged RBCs followed by ECG gated blood pool imaging over the chest (MUGA study). Bland-Altman analysis was used to compare the measurements. RESULTS: A total of 32 subjects with proven or suspected ischemic heart disease, but without overt cardiac failure, edema or arrhythmias were studied (M:F::26:6; mean age: 48 +/- 12 years). The mean TEB-CO was 3.54 +/- 1.052 l/min and mean RNEC-CO was 3.907 +/- 0.952 l/min. Correlation coefficient (r) for these measurements was 0.67 (p < 0.01), with bias: -0.421 l/min; precision: 1.557 l/min; and percentage error of measurement: 42.35%. CONCLUSIONS: This study observed a moderate correlation between TEB and RNEC methods of CO measurement. Further studies are indicated to explore the relative utility of TEB in comparison with RNEC as well as other methods of CO measurement before considering its use in patients with ischemic heart disease.


Asunto(s)
Gasto Cardíaco , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/métodos , Cardiografía de Impedancia/métodos , Disfunción Ventricular Izquierda/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA