Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Curr Med Imaging ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39041255

RESUMEN

BACKGROUND: Prostate cancer, a significant contributor to male cancer mortality globally, demands improved diagnostic strategies. In Saudi Arabia, where the incidence is expected to double, this study assessed the compliance of multiparametric MRI (mpMRI) practices with Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) guidelines across diverse healthcare institutions. METHODS: A survey was distributed to the radiology departments of all tertiary referral hospitals in Saudi Arabia (n=60) to assess their compliance with the technical specifications outlined in PI-RADS v2. Statistical analysis included chi-square, Fisher exact, ANOVA, and Student t-tests to examine the collected data. RESULTS: The study revealed an overall commendable compliance rate of 95.23%. However, significant variations were observed in technical parameters, particularly between 1.5 Tesla and 3 Tesla scanners and tertiary versus non-tertiary hospitals. Notable adherence in certain sequences contrasted with discrepancies in T2-weighted and diffusion-weighted imaging parameters. CONCLUSION: These findings underscore the need for nuanced approaches to optimize prostate imaging protocols, considering field strength and institutional differences. The study contributes to the ongoing refinement of standardized mpMRI practices, aiming to enhance diagnostic accuracy and improve clinical outcomes in prostate cancer.

2.
Healthcare (Basel) ; 11(18)2023 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-37761705

RESUMEN

BACKGROUND: The lack of local guidelines and regulations for the administration of anesthesia in magnetic resonance imaging (MRI) units presents a potential risk to patient safety in Saudi Arabia. Hence, this study aimed to evaluate the extent to which hospitals in Saudi Arabia follow international guidelines and recommendations for the safe and effective administration of anesthesia in an MRI environment. METHODS: This study used a questionnaire that was distributed to 31 medical facilities in Saudi Arabia that provided anesthesia in MRI units. RESULTS: The findings of the study revealed that the mean compliance with the 17 guidelines across the 31 sites was 77%; 5 of the 31 sites (16.1%) had a compliance rate of less than 50% with the recommended guidelines. Only 19.4% of the institutes provided general safety education. Communication breakdowns between anesthesia providers and MRI teams were reported. CONCLUSIONS: To conclude, this survey highlights the status of anesthesia standards in Saudi Arabian MRI units and emphasizes areas that require better adherence to international guidelines. The results call for targeted interventions, including the formulation of specific national anesthesia guidelines for MRI settings. Communication breakdowns between anesthesia providers and MRI teams were reported at a rate of 83.9% during the administration of a gadolinium contrast agent. There were additional breakdowns, particularly for high-risk patients with implants, such as impaired respirators (74.2%), thus requiring further investigation due to potential safety incidents during MRI procedures. While considering the limitations of this study, such as potential biases and the low response rate, it provides a valuable foundation for refining protocols and promoting standardized practices in Saudi Arabian healthcare.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA