Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 140(2): 203-208, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31707483

RESUMEN

INTRODUCTION: The complications of the open-wedge osteotomy technique (slope, hypo- and hypercorrection and fractures) are related to difficulties in the control of the open-wedge angle during surgery. MATERIALS AND METHODS: In this cadaveric study, we evaluated the safety and precision of a novel system, the Realignment High Control System (RHC), in the correction of knee mechanical axis and slope. The RHC has a fixation plate coupled to a dynamic device that opens the osteotomy continuously, allowing plate fixation before osteotomy wedge opening. RESULTS: All procedures were easily performed, with no fractures. The openings equaled the indicated by the navigation system for 7.5° and 10°, and for 5°, there was a statistically, although not clinically significant, difference of 0.6°. The slope shown by the RHC setting and in the navigation system was significantly different for the 10° setting only, with a mean difference of 0.563°. CONCLUSIONS: RHC facilitates the surgical technique of high tibial osteotomy, with gradual wedge opening, precise correction of the mechanical axis, and appropriate control of the tibial slope, even with larger openings.


Asunto(s)
Osteotomía/efectos adversos , Osteotomía/instrumentación , Tibia/cirugía , Humanos , Seguridad del Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA