Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur J Appl Physiol ; 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39235602

RESUMEN

The short-term scaling exponent of detrended fluctuation analysis (DFAα1) applied to interbeat intervals may provide a method to identify ventilatory thresholds and indicate systemic perturbation during prolonged exercise. The purposes of this study were to (i) identify the gas exchange threshold (GET) and respiratory compensation point (RCP) using DFAα1 values of 0.75 and 0.5 from incremental exercise, (ii) compare DFAα1 thresholds with DFAα1 measures during constant-speed running near the maximal lactate steady state (MLSS), and (iii) assess the repeatability of DFAα1 between MLSS trials. Twelve runners performed an incremental running test and constant-speed running 5% below, at, and 5% above the MLSS, plus a repeat trial at MLSS. During 30-min running trials near MLSS, DFAα1 responses were variable (i.e., 0.27-1.24) and affected by intensity (p = 0.031) and duration (p = 0.003). No difference in DFAα1 was detected between MLSS trials (p = 0.597). In the early phase (~ 8 min), DFAα1 measures at MLSS (0.71 [0.13]) remained higher than the DFAα1 identified at RCP from the incremental test (0.57 [0.13]; p = 0.024). In addition, following ~ 18 min of constant speed running at MLSS, DFAα1 measures (0.64 [0.14]) remained higher than 0.5 (p = 0.011)-the value thought to demarcate the boundaries between heavy and severe exercise intensities. Accordingly, using fixed DFAα1 values associated with the RCP from incremental exercise to guide constant-speed exercise training may produce a greater than expected exercise intensity, however; the dependency of DFAα1 on intensity and duration suggest its potential utility to quantify systemic perturbations imposed by continuous exercise.

2.
Phys Rev Lett ; 124(17): 171102, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32412252

RESUMEN

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

3.
Int J Clin Pharm ; 41(6): 1592-1598, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31650506

RESUMEN

Background To improve antimicrobial use, incorporation of a pharmacist in antimicrobial stewardship initiatives in the emergency department has been recommended. Recognizing the potential value, a pharmacist-led antimicrobial stewardship (AMS) service which included review and follow up of microbiology results for patients discharged from the pediatric emergency department (PED) with suspected infections was implemented at our local institution. Objective The objective of this study was to evaluate the impact of pharmacists delivering this service compared to usual care. Setting Pediatric emergency department at the IWK Health Centre in Halifax, Canada. Method This study was completed as a retrospective chart review of pediatric patients discharged from the PED 6 months before and after implementation of the pharmacist-led AMS service. Data was extracted from electronic medical records. Data were reported descriptively and compared using a two-sided chi-square test and ordinal logistic regression. Main outcome measures The primary outcome measure was rate of return visits to the PED within 96 h of initial presentation. Results This study included 1070 patient encounters pre-implementation and 1040 patient encounters post-implementation. The rate of return visits to the PED within 96 h was 12.0% (129/1070) pre-implementation vs. 10.0% (100/1049) post-implementation (p = 0.07). The rate of return visits or hospitalization at 30 days was 22.1% (237/1070) pre-implementation compared to 19.9% (207/1040) in the post-implementation phase (p = 0.21). Inappropriate antimicrobial therapy was identified more often in the pre-implementation phase (7.0%, 68/975) vs. the post-implementation phase (5.0%, 46/952), p = 0.047. Time to notification within the first day after discharge occurred more frequently in the post-implementation phase (53.3%, 80/150) as compared to the pre-implementation phase (40.3%, 52/129, p = 0.0298). Conclusion Although this pharmacist-led AMS service did not significantly affect the rate of return visits or hospitalization, it may have led to more judicious use of antimicrobial agents and faster time to notification.


Asunto(s)
Programas de Optimización del Uso de los Antimicrobianos , Servicio de Urgencia en Hospital/organización & administración , Farmacéuticos/organización & administración , Servicio de Farmacia en Hospital/organización & administración , Antiinfecciosos/administración & dosificación , Niño , Preescolar , Registros Electrónicos de Salud , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Prescripción Inadecuada/estadística & datos numéricos , Lactante , Masculino , Nueva Escocia , Readmisión del Paciente/estadística & datos numéricos , Rol Profesional , Estudios Retrospectivos
4.
Rev Sci Instrum ; 87(6): 065002, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27370484

RESUMEN

Tilt-horizontal coupling in inertial sensors limits the performance of active isolation systems such as those used in gravitational wave detectors. Inertial rotation sensors can be used to subtract the tilt component from the signal produced by horizontal inertial sensors, but such techniques are often limited by the sensor noise of the tilt measurement. A different approach is to mechanically filter the tilt transmitted to the horizontal inertial sensor, as discussed in this article. This technique does not require an auxiliary rotation sensor and can produce a lower noise measurement. The concept investigated uses a mechanical suspension to isolate the inertial sensor from input tilt. Modeling and simulations show that such a configuration can be used to adequately attenuate the tilt transmitted to the instrument, while maintaining translation sensitivity in the frequency band of interest. The analysis is supported by experimental results showing that this approach is a viable solution to overcome the tilt problem in the field of active inertial isolation.

5.
Respir Physiol Neurobiol ; 180(1): 40-4, 2012 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-22027218

RESUMEN

Nitric oxide is a gaseous signaling molecule that participates in a large variety of physiological functions and may have a role in the pathology of altitude illnesses, such as acute mountain sickness (AMS). The effect of normobaric hypoxia on the fraction of exhaled NO ( [Formula: see text] ) is a controversial area of high altitude physiology, with the effect varying widely across studies. We exposed 19 male subjects to normobaric hypoxia for 6h and measured [Formula: see text] and AMS (via Lake Louise Score) each hour. For data analysis, subjects were divided into AMS-positive and AMS-negative groups based on their Lake Louise Scores during exposure. Eighteen subjects completed the study, and the incidence of AMS was 50%. Mean [Formula: see text] was unchanged at hour 1 but was significantly elevated above baseline for the remainder of the normobaric hypoxia exposure (p<0.001). Subjects who developed AMS had a significantly lower mean [Formula: see text] at baseline compared to resistant subjects (p=0.013). Further investigations are warranted to confirm our results and to understand the physiological basis of this association.


Asunto(s)
Mal de Altura/metabolismo , Hipoxia/complicaciones , Óxido Nítrico/análisis , Óxido Nítrico/metabolismo , Mal de Altura/etiología , Susceptibilidad a Enfermedades/metabolismo , Espiración , Humanos , Hipoxia/metabolismo , Masculino
6.
Am J Clin Pathol ; 88(1): 78-82, 1987 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-3300267

RESUMEN

The histopathology of rectosigmoid biopsies from 20 patients with bloody diarrhea resulting from verotoxin-producing Escherichia coli infection is reported. The biopsies displayed a range of appearances, from normal to mild, nonspecific inflammation to acute infectious-type colitis. Surface-adherent or invasive bacteria were not identified. The morphologic features of infectious colitis and the absence of bacteria suggest that verotoxin may be responsible for the pathologic changes.


Asunto(s)
Toxinas Bacterianas/aislamiento & purificación , Colitis/patología , Colon Sigmoide/patología , Diarrea/etiología , Infecciones por Escherichia coli/patología , Recto/patología , Biopsia , Colitis/etiología , Escherichia coli/metabolismo , Humanos , Mucosa Intestinal/patología , Toxina Shiga I
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA