Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Spine Surg ; 29(1): E49-54, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23429320

RESUMEN

STUDY DESIGN: A retrospective case series describing teardrop fracture of the axis. OBJECT: The purpose of the study was to clarify the clinical features, the mechanism of injury, and the potential instability of extension teardrop fractures of the axis, so as to emphasize the importance of recognizing this injury as a separate entity. SUMMARY OF BACKGROUND DATA: Teardrop fractures of the axis are rare spinal fractures, comprising only a small percentage of all injuries of the cervical spine. The stability of this fracture pattern has been a matter of debate leading to controversy regarding treatment strategies and the need for stabilization. METHODS: We retrospectively reviewed data collected from 16 patients to document the mechanism of injury, neurological deficit, treatment and clinical outcome, and imaging findings. RESULTS: Extension teardrop fractures accounted for approximately 8.9% of the upper cervical spinal injuries and 12.7% of axis fractures at the authors' institution over the same period. Six patients (4 males and 2 females) underwent surgery (4 by an anterior approach, 2 by a posterior approach). Ten cases underwent Halo-vest immobilization for a period between 6 and 12 weeks. At final follow-up, 14 cases achieved excellent results, whereas 2 patients complained of mild residual neck pain. Maximum cranial-caudal dimensions of the fragments were between 5 and 24 mm (average, 12.9 mm), and the transverse dimensions were between 5 and 22 mm (average, 11.1 mm). Fragment displacement ranged from 1 to 9 mm (average, 3.5 mm), whereas fragment rotation ranged from 10 to 52 degrees (average, 24.4 degrees) in the sagittal plane. CONCLUSIONS: Most patients with an extension teardrop fracture of the axis can be treated conservatively. On the basis of this case series, the authors suggest that large fragment size, displacement or angulation, intervertebral disk injury, neurologic deficit, or signs of instability are reasonable indications for surgical treatment.


Asunto(s)
Vértebra Cervical Axis/lesiones , Fracturas de la Columna Vertebral/terapia , Adulto , Anciano , Vértebra Cervical Axis/diagnóstico por imagen , Femenino , Fijación Interna de Fracturas , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Radiografía , Estudios Retrospectivos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/patología , Fracturas de la Columna Vertebral/cirugía , Resultado del Tratamiento , Adulto Joven
2.
J Spinal Disord Tech ; 27(6): E219-25, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24463337

RESUMEN

STUDY DESIGN: This is a retrospective, clinical, and radiologic study of posterior reduction and fusion of the C1 arch in the treatment of unstable Jefferson fractures. OBJECTIVE: The aim of the study was to describe a new motion-preserving surgical technique in the treatment of unstable Jefferson fracture. SUMMARY OF BACKGROUND DATA: The management of unstable Jefferson fractures remains controversial. The majority of C1 fractures can be effectively treated nonoperatively with external immobilization unless there is an injury to the transverse atlantal ligament (TAL). Conservative treatment usually involves immobilization for a long time in Halo vest, whereas surgical intervention generally involves C1-C2 fusion, eliminating the range of motion of the upper cervical spine. We propose a novel method for the treatment of unstable Jefferson fractures without restricting the range of motion. METHODS: A retrospective review of 12 patients with unstable C1 fractures between April 2008 and October 2011 was performed. They were treated by inserting bilateral posterior C1 pedicle screws or lateral mass screws interconnected by a transversal rod to achieve internal fixation. There were 8 men and 4 women, with an average age of 35.6 years (range, 20-60 y). Presenting symptoms included neck pain, stiffness, and decreased range of motion but none had neurological injury. Seven patients had bilateral posterior arch fractures associated with unilateral anterior arch fractures (posterior 3/4 Jefferson fracture, Landells type II), and 5 had unilateral anterior and posterior arch fractures (half-ring Jefferson fracture, Landells type II). Seven patients had intact TAL, and 5 patients had fractures and avulsion of the attachment of TAL (Dickman type II). RESULTS: A total of 24 screws were inserted. Five cases had screws placed in the lateral mass: 3 because of posterior arch breakage, and 2 because the height of the posterior arch at the entry point was <4 mm. The remaining 7 cases had pedicle screw fixation. One patient had venous plexus injury during exposure of lower margin of the posterior arch; however, successful hemostasis was achieved with Gelfoam. Postoperative x-ray and computed tomography scan showed partial breach of the transverse foramen caused by a screw in 1 case, and breach of the inner cortex of the pedicle caused by screw displacement in 1 case; however, no spinal cord injury or vertebral artery injury was found. The remaining screws were in good position. Patients were followed up for 6-40 months (average, 22 mo). All cases had recovery of range of motion of the cervical spine to the preinjury level by 3-6 months after surgery, with resolution of pain. At 6 months follow-up, plain radiographs and computed tomography scans revealed satisfactory cervical alignment, no implant failure, and satisfactory bony fusion of the fractures; no C1-C2 instability was observed on the flexion-extension radiographs. CONCLUSIONS: C1 posterior limited construct is a valid technique and a feasible method for treating unstable Jefferson fractures, which allows preservation of the function of the craniocervical junction, without significant morbidity.


Asunto(s)
Vértebras Cervicales/fisiopatología , Vértebras Cervicales/cirugía , Fijación Interna de Fracturas/métodos , Fracturas de la Columna Vertebral/fisiopatología , Fracturas de la Columna Vertebral/cirugía , Adulto , Tornillos Óseos , Vértebras Cervicales/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Dolor de Cuello/fisiopatología , Dolor de Cuello/cirugía , Rango del Movimiento Articular , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA