Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Food Chem ; 135(4): 2988-93, 2012 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-22980901

RESUMEN

A simple, rapid and sensitive method was developed for determination of 17α-methyltestosterone in aquatic products by extraction with subcritical 1,1,1,2-tetrafluoroethane (R134a) extraction and high performance liquid chromatography (HPLC). Response surface methodology (RSM) was adopted to optimise extraction pressure, temperature and co-solvent volume. The optimum extraction conditions predicted within the experimental ranges were as follows: pressure 5 MPa, temperature 31°C, and co-solvent volume 3.35ml. The analysis was carried out on XDB-C(18) column (4.6 mm × 250 mm, 5 µm) with the mobile phase acetonitrile-water (55:45, v/v), flow rate 0.8 ml/min, temperature 30°C and wavelength 245 nm. Good linearity of detection was obtained for 17α-methyltestosterone between concentrations of 50-250 ng/ml, r(2)=0.999. The method was validated using samples fortified with 17α-methyltestosterone at levels of 10, 30 and 50 ng/g, the mean recovery exceeds 90%, and the RSD values were less than 10%.


Asunto(s)
Andrógenos/análisis , Cromatografía con Fluido Supercrítico/métodos , Residuos de Medicamentos/aislamiento & purificación , Carne/análisis , Metiltestosterona/aislamiento & purificación , Andrógenos/aislamiento & purificación , Animales , Cromatografía Líquida de Alta Presión/métodos , Cromatografía con Fluido Supercrítico/instrumentación , Residuos de Medicamentos/análisis , Peces , Hidrocarburos Fluorados/química , Metiltestosterona/análisis
2.
Artículo en Inglés | MEDLINE | ID: mdl-22546199

RESUMEN

A simple, rapid and sensitive method was developed for the determination of medroxyprogesterone in aquatic products by extraction with subcritical 1,1,1,2-tetrafluoroethane (R134a) and high performance liquid chromatography (HPLC). A response surface methodology (RSM) was adopted to optimise extraction pressure, temperature and co-solvent volume. The optimum extraction conditions predicted within the experimental ranges were as follows: pressure, 3 MPa; temperature, 25 °C; and co-solvent volume, 6 ml. The analysis was carried out on Zorbax SB-C18 column (4.6 mm × 150 mm, 5 µm) with the mobile phase acetonitrile-water (55:45, v/v), flow rate 1.0 ml/min, temperature 30 °C and wavelength 240 nm. Good linearity of detection was obtained for medroxyprogesterone between concentrations of 50-250 ng/ml, r²=0.999. The method was validated using samples fortified with medroxyprogesterone at levels of 10, 30 and 50 ng/g, the mean recovery exceeds 90%, and the RSD values were less than 10%.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía con Fluido Supercrítico/métodos , Medroxiprogesterona/análisis , Alimentos Marinos/análisis , Análisis de Varianza , Animales , Cromatografía Líquida de Alta Presión/normas , Cromatografía con Fluido Supercrítico/normas , Residuos de Medicamentos/análisis , Residuos de Medicamentos/aislamiento & purificación , Medroxiprogesterona/aislamiento & purificación , Análisis de Regresión , Reproducibilidad de los Resultados , Tilapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA