Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Orthop Surg Res ; 19(1): 565, 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39272126

RESUMEN

BACKGROUND: In modern Hybrid ORs, the synergies of navigation and robotics are assumed to contribute to the optimisation of the treatment in trauma, orthopaedic and spine surgery. Despite promising evidence in the area of navigation and robotics, previous publications have not definitively proven the potential benefits. Therefore, the aim of this retrospective study was to evaluate the potential benefit and clinical outcome of patients treated in a fully equipped 3D-Navigation Hybrid OR. METHODS: Prospective data was collected (March 2022- March 2024) after implementation of a fully equipped 3D-Navigation Hybrid OR ("Robotic Suite") in the authors level 1 trauma centre. The OR includes a navigation unit, a cone beam CT (CBCT), a robotic arm and mixed reality glasses. Surgeries with different indications of the spine, the pelvis (pelvic ring and acetabulum) and the extremities were performed. Spinal and non-spinal screws were inserted. The collected data was analysed retrospectively. Pedicle screw accuracy was graded according to the Gertzbein and Robbins (GR) classification. RESULTS: A total of n = 210 patients (118 m:92f) were treated in our 3D-Navigation Hybrid OR, with 1171 screws inserted. Among these patients, 23 patients (11.0%) arrived at the hospital via the trauma room with an average Injury Severity Score (ISS) of 25.7. There were 1035 (88.4%) spinal screws inserted at an accuracy rate of 98.7% (CI95%: 98.1-99.4%; 911 GR-A & 111 GR-B screws). The number of non-spinal screws were 136 (11.6%) with an accuracy rate of 99.3% (CI95%: 97.8-100.0%; 135 correctly placed screws). This resulted in an overall accuracy rate of 98.8% (CI95%: 98.2-99.4%). The robotic arm was used in 152 cases (72.4%), minimally invasive surgery (MIS) was performed in 139 cases (66.2%) and wound infection occurred in 4 cases (1,9%). Overall, no revisions were needed. CONCLUSION: By extending the scope of application, this study showed that interventions in a fully equipped 3D-Navigation Hybrid OR can be successfully performed not only on the spine, but also on the pelvis and extremities. In trauma, orthopaedics and spinal surgery, navigation and robotics can be used to perform operations with a high degree of precision, increased safety, reduced radiation exposure for the OR-team and a very low complication rate.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Adulto , Anciano , Adulto Joven , Imagenología Tridimensional/métodos , Columna Vertebral/cirugía , Columna Vertebral/diagnóstico por imagen , Traumatismos Vertebrales/cirugía , Traumatismos Vertebrales/diagnóstico por imagen , Adolescente , Procedimientos Ortopédicos/métodos , Procedimientos Ortopédicos/instrumentación , Tornillos Pediculares , Anciano de 80 o más Años , Estudios Prospectivos , Cirugía Asistida por Computador/métodos , Cirugía de Cuidados Intensivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA