Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Clin Ophthalmol ; 16: 3391-3404, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36249443

RESUMEN

Background: Despite the abundance of novel surgical approaches proposed for full thickness macular hole (FTMH) treatment, the choice of the optimal technique remains debatable Vitrectomy with «classic¼ internal limiting membrane peeling and gas tamponade remains the standard of FTMH surgery in many cases, but there are still very limited recent publications on the outcomes of such surgery. Purpose: To investigate the anatomical and functional result and to analyze the significance of outcome-related risk factors of the classic 25-gauge pars plana vitrectomy (PPV) with ILM peeling and gas tamponade (GT) for treatment of FTMH of different etiology. Patients and methods: Thirty-eight eyes of thirty-seven patients with FTMH who underwent 25-gauge PPV, ILM peeling and GT were recruited for this retrospective, consecutive, interventional study. Four eyes with persistent holes underwent a re-operation. Outcome-related factors were discussed. Results: The primary closure rate was 89.5% (34/38). All eyes that underwent the repeated surgery (4 cases) obtained final closure. A hole size of >500 µm has a statistically significant effect on the primary macular hole closure (F = 0.048; φ = 0.38; p ˂ 0.05). In the general group (N = 38), the duration of symptoms directly correlated with age (ρ = 0.34; p = 0.04), size of the hole (ρ = 0.66; p ˂ 0.001) and BCVA before surgery (ρ = 0.59; p ˂ 0.001), after 1 month (ρ = 0.36; p = 0.03), and after 3 months (ρ = 0.35; p = 0.03). Preoperative BCVA was better in initially closed cases (Group 1) (U = 26.0; p = 0.05). In the Group 2 with primary unclosed holes, 75% of the eyes (3/4) had an axial length (AL) >26 mm, while in Group 1 such eyes were 12.5 times less (2/34) 5.9% (F = 0.004; φ = 0.63; р ˂ 0.01). The ELM recovery rate at 3 months was 92% (35/38 eyes) and the restoration of EZ at 3 months was 47% (18/38 eyes). Best-corrected visual acuity of all individuals improved significantly from 0.72 ± 0.35 (logMAR) (Me = 0.7; IQR: 0.5-0.8) to 0.25±0.14 (logMAR) (Me = 0.2; IQR: 0.2 - 0.3) at 1 month and 0.17 ± 0.13 (logMAR) (Me = 0.2; IQR: 0.1 - 0.2) at 3 months after surgery (P = 0.0001). Conclusion: 25G PPV with ILM and GT for FTMH of different etiology provide satisfactory morphologic and functional outcomes. Elongated AL, large diameter of MH and long duration of symptoms are the risk factors for initial closure. Proper second surgery can obtain satisfactory outcomes for persistent holes.

3.
Ophthalmol Ther ; 10(3): 643-658, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34231188

RESUMEN

INTRODUCTION: The choice of surgical treatment for chronic, persistent and large full-thickness macular holes (FTMH) continues to be undefined and challenging, as some of these cases remain refractory to the treatment. We report the efficacy of combination of inverted internal limiting membrane flap technique (IILMFT) and subretinal application of the fluid (SR fluid application) technique for treatment of refractory FTMHs. METHODS: Nine patients (nine eyes) were enrolled into this retrospective non-randomized exploratory consecutive case series study. All patients were diagnosed with chronic, persistent or large FTMH and were treated with a combination of IILMFT and SR fluid application technique. The following outcome parameters were analysed during 1- and 6-month follow-up visits: anatomical FTMH closure rate on spectral domain optical coherence tomography (SD-OCT), best-corrected visual acuity (BCVA), degree of postoperative retinal displacement. RESULTS: The mean preoperative diameter of FTMH was 542.0 µm (range 154-1930 µm). Final closure of FTMH was achieved in nine of nine cases (100%). In one case a second operation was required because of postoperative rhegmatogenous retinal detachment. The mean BCVA after the FTMH closure increased from 1.0 logMAR (0.7-1.3) to 0.4 logMAR (0.2-0.8 logMAR) (W = 2.67; p = 0.008). A positive correlation was revealed between preoperative BCVA and axial length (ρ = 0.67, p = 0.048), between preoperative BCVA and duration of the symptoms (ρ = 0.818, p = 0.007), as well as between postoperative BCVA at 1-month follow-up and BCVA at 6-month follow-up (ρ = 0.821, p = 0.007). CONCLUSION: Combination of IILMFT with SR fluid application technique for refractory FTMH surgery appears to be effective and safe. Improvement of anatomical and visual outcomes after the single surgery benefits from and is ensured by the advantages of both novel surgical approaches.

4.
Clin Ophthalmol ; 15: 723-734, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33642853

RESUMEN

PURPOSE: To study the efficacy of a novel needle for intravitreal injection (IVI) in comparison to the conventional needle under experimental conditions. METHODS: The newly designed 30-gauge (G) needle (NDN) (EP 18158 542.3, patent pending) with occluded outer orifice and a side port for drug delivery was compared to the conventional standard hypodermic 30 G needle for IVI (SHN). An animal study to obtain needle tip aspirates was performed on 10 albino rat eyes. During IVIs, cellular content, which was cut by the needle tip, was aspirated. Cellular material was studied in regard to cell types and their quantity. The injection stream was studied using trypan blue dye in vitro and pig cadaver eyes. The penetration force was tested on polyurethane Testing Foil Strips PU 04 (Melab, Leonberg, Germany) by applying a velocity of 100 mm/min. The results were analyzed using descriptive statistics, correlation matrices and t-test methods with p<0.05 as statistically significant. RESULTS: Cytological analysis of the needle aspirates showed the presence of cellular content in each case. The amount of conjunctival, ciliary body epithelial cells and granulated basophilic protein sediments (sign of cellular damage) in the case of the NDN tips was significantly lower compared to the SHN. The average penetration force of the NDN was 0.791 N, and in the case of the SHN was 0.566 N. The injection stream study revealed a difference in the initial injection phase between the two needle types, although the diffuse filling of the vitreous area which surrounded the needle tip appeared to be similar. DISCUSSION: The NDN demonstrated superior performance with regard to a significantly reduced number of cells being captured by the needle tip. Delivery of the injected fluid into the vitreous cavity was comparable. In order to investigate superior properties of the NDN needle design, further studies with improved prototypes would be necessary.

5.
Acta Ophthalmol ; 98(2): e144-e154, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31421029

RESUMEN

PURPOSE: To report the rate and management of intra- and early postoperative complications of bag-in-the-lens intraocular lens (IOL) implantation technique for cataract treatment in paediatric patients of different age groups. SETTINGS: Department of Ophthalmology, Justus-Liebig-University Giessen, University Hospital Giessen and Marburg GmbH, Campus Giessen, Giessen, Germany. DESIGN: Retrospective non-randomized consecutive case series. METHODS: Ninety eyes of 60 paediatric cataract patients were enrolled to this retrospective non-randomized observational consecutive case series single-centre study. All patients underwent cataract surgery with bag-in-the-lens IOL implantation between January 2008 and December 2018, performed by two experienced surgeons. The entire cohort was divided into four age groups: first - 0-<3 months, second - 3-<12 months, third - 12-<36 and fourth - >36 months-17 years of age. The intra- and postoperative complications were based on the clinical records. The description of management of complications related specifically to bag-in-the-lens IOL technique was based on the 39 consecutive cases operated since 1 Jan 2016 by one single surgeon that were all video documented. The early postoperative period was defined as 12 months after surgery. RESULTS: Overall, there were 27 unilateral and 33 bilateral surgical cases of 24 female and 36 male children. The mean age at surgery was 45.25 months (range 1-200 months). The most common intraoperative events were vitreous prolapse and anterior capsule rupture with 28.9% and 13.3%, respectively. Within 12 months of follow-up, five eyes (5.6%) were re-operated because of visual axis reo-pacification (VAR). Intraocular hypertension was diagnosed in seven eyes (7.8%), including two cases that required surgical treatment. In all cases with intra- and early postoperative complications related specifically to bag-in-the-lens technique, it was possible to manage them and successfully implant bag-in-the-lens IOL. CONCLUSIONS: Implementation of bag-in-the-lens technique in the treatment of paediatric cataract was associated with a relatively low rate of intra- and postoperative complications, including rare cases of VAR. The correct management of complications related specifically to bag-in-the-lens IOL implantation technique shall to be considered during the learning curve.


Asunto(s)
Extracción de Catarata , Complicaciones Intraoperatorias/cirugía , Implantación de Lentes Intraoculares/métodos , Complicaciones Posoperatorias/cirugía , Adolescente , Capsulorrexis , Catarata/congénito , Niño , Preescolar , Femenino , Alemania , Humanos , Lactante , Recién Nacido , Masculino , Seudofaquia/fisiopatología , Estudios Retrospectivos , Agudeza Visual/fisiología , Vitrectomía
6.
J Cataract Refract Surg ; 45(10): 1372-1379, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31564311

RESUMEN

PURPOSE: To evaluate the precision of bag-in-the-lens intraocular lens (BIL IOL) power calculation in different age groups of pediatric cataract patients. SETTINGS: Department of Ophthalmology, Justus-Liebig-University Giessen, University Hospital Giessen and Marburg GmbH, Campus Giessen, Giessen, Germany. DESIGN: Retrospective nonrandomized consecutive case series. METHODS: Pediatric patients diagnosed with cataract and operated with BIL IOL implantation were divided into 4 age groups: Group 1 (0 to 3 months), Group 2 (>3 months, <12 months), Group 3 (12 to 36 months), and Group 4 (>36 months to 17 years). BIL IOL power was calculated with the SRK/T formula. The prediction error (PE) was defined as the absolute difference between the preoperative selected target and postoperative achieved refraction. The impact of age at the time of surgery, axial length (AL), keratometry, and corneal astigmatism on PE was analyzed. RESULTS: The study comprised 87 eyes of 56 pediatric patients. The mean and median PEs for the entire group were 1.79 diopters (D) and 1.23 D, respectively. The mean PE in each age group was: 3.43 D in Group 1, 2.14 D in Group 2, 1.60 D in Group 3, and 1.33 D in Group 4. The mean PE in eyes with ALs shorter than 20 mm was 2.67 D, and 1.44 D in eyes with an AL of 20 mm or longer. The mean PE in eyes with corneal radii less than 7.3 mm was 2.45 D, and 1.66 D in eyes with corneal radii of 7.3 mm or more. In the age and AL subgroups, the PE differences were statistically significant (P < .05). CONCLUSIONS: The PE was larger in the youngest study group, and it decreased gradually with age and in eyes with ALs shorter than 20 mm. The PE has to be considered during BIL IOL power calculation in children.


Asunto(s)
Cápsula del Cristalino/cirugía , Implantación de Lentes Intraoculares , Óptica y Fotónica , Facoemulsificación , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Adolescente , Astigmatismo/fisiopatología , Biometría , Catarata/patología , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología
8.
Graefes Arch Clin Exp Ophthalmol ; 257(8): 1649-1659, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31139918

RESUMEN

BACKGROUND/OBJECTIVES: To assess the efficacy of dynamic intraoperative spectral-domain optical coherence tomography (iSD-OCT) imaging for inverted internal limiting membrane (ILM) flap technique (IILMFT) in large macular hole (MH) surgery. SUBJECTS/METHODS: Prospective, non-randomized, observational study was conducted on 8 eyes of 7 patients with large, chronic and recurrent MHs, which were treated by pars plana vitrectomy (PPV) with IILMFT. All patients underwent standard pre- and postoperative examination. The iSD-OCT imaging was performed using microscope integrated systems before, during, and after ILM peeling. The iSD-OCT data were post-processed using graphic software and reviewed for tissue behavior and instruments position. RESULTS: The real-time iSD-OCT-assisted IILMFT allowed for real-time imaging of the entire surgery with visualization of the MH, vitreoretinal instruments, and all steps of inverted ILM flap formation. In spite of shadowing created by the steel instruments, it was possible to follow and control the distance between the instrument tips and retinal layers. Dynamic imaging of the surgical maneuvers including ILM peeling and mechanical apposition of MH edges revealed the iatrogenic impact on the retina (depression and appearance of hyporeflective zones). iSD-OCT imaging could confirm the proper position of the inverted ILM flap at the very end of the surgery after fluid-air exchange. CONCLUSIONS: iSD-OCT imaging is an effective tool for learning and performing a well-controlled and safe inverted ILM flap technique in patients with large MH. Clinical significance of the structural iSD-OCT findings has to be further studied.


Asunto(s)
Membrana Basal/trasplante , Mácula Lútea/patología , Perforaciones de la Retina/cirugía , Colgajos Quirúrgicos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Vitrectomía/métodos , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Mácula Lútea/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Perforaciones de la Retina/diagnóstico , Resultado del Tratamiento
9.
Ophthalmol Retina ; 3(1): 73-76, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30935659

RESUMEN

PURPOSE: To report the efficacy of the use of a new scleral depressor marker during scleral buckling surgery for retinal detachment. DESIGN: Noncomparative, consecutive case series study. PARTICIPANTS: Eleven patients (11 eyes) with rhegmatogenous retinal detachment who underwent scleral buckling surgery performed by 2 experienced vitreoretinal surgeons. METHODS: The prototype of a new indenter marker was used during scleral buckling surgery. MAIN OUTCOME MEASURES: The possibility of performing simultaneous indentation and selected marking of the desired area was assessed. Additionally, the precision of the fiber light-assisted indentation as well as force of indentation were evaluated. RESULTS: The use of a new depressor marker facilitated a quick and effective flow of the standard surgery for retinal detachment. It was possible to perform indentation and marking as separate steps of 1 session. Only desired areas of the sclera were marked during the same indentation session. The indentation required less force. When combined with chandelier light, the precision of the marking was improved as demonstrated by a light from the chandelier indicating the highest point of the indentation area. There were no complications related to the use of the new instrument. CONCLUSIONS: The newly developed scleral depressor marker facilitated simultaneous indentation and marking on the sclera. The new instrument allowed for the selective marking of the desired areas during the same session of indentation. Additionally, it can be combined with chandelier fiber light, which improves the precision of the marking.


Asunto(s)
Desprendimiento de Retina/cirugía , Esclerótica/diagnóstico por imagen , Curvatura de la Esclerótica/instrumentación , Agudeza Visual , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Oftalmoscopía , Retina/patología , Retina/cirugía , Desprendimiento de Retina/diagnóstico , Esclerótica/cirugía , Resultado del Tratamiento , Adulto Joven
10.
BMC Ophthalmol ; 17(1): 134, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28764684

RESUMEN

BACKGROUND: The pathogenesis of non-rhegmatogenous retinal detachment (non-RRD) associated with morning glory syndrome (MGS) is not established, as well as best surgical approach to treat RD. Our purpose was to analyse intraoperative optical coherence tomography data (iOCT) in all steps of pars plana vitrectomy (PPV) for non-RRD in MGS, in order to follow pathophysiological aspects of the disease and to understand the tissues behaviour during surgical workflow. CASE PRESENTATION: Intraoperative spectral domain optical coherent tomography (iSD-OCT) assisted PPV using Rescan 700 (Carl Zeiss Meditech, Jena, Germany) with epiretinal membrane (ERM) and internal retinal membrane (ILM) peeling, and air endotamponade was performed on the only eye of a 21 years old female with non-RRD associated with MGS. BCVA, pre-, intra- and postoperative OCT were performed along with standard ocular examination. iOCT video and snapshots were analysed intra- and postoperatively using post-processing approach using graphic software. The progression of non-RRD resulted in best corrected visual acuity (BCVA) decrease from 0.8 to 0.2. Triamcinolone enhanced iOCT imaging revealed strong vitreous traction and adhesion above the macula and optic disc. Internal limiting membrane was peeled under iOCT control to prevent the peeling of inner layers of the retinal schisis. No retinal break was detected, and only air endotamponade was performed. The retina reattached during first 4 weeks of follow-up with gradual resolution of intraretinal- and subretinal fluid, and remained stable in 12 months. BCVA improved to 0.8. CONCLUSION: Based on iSD-OCT findings we assume that non-RRD in this case of MGS is caused primarily by the vitreous traction with further possible formation of the retinal breaks. Retinal reattachment reached only with air endotamponade strongly advocates the tractional component of non-RRD and retinal schisis assotiated with MGS. Early PPV for central non-RRD and retinal schisis with the use of iOCT can be performed in more safe and controlled manner and has to be considered to reduce the risk of retinal break formation and to prevent the central vision loss.


Asunto(s)
Disco Óptico/anomalías , Enfermedades del Nervio Óptico/complicaciones , Retina/patología , Desprendimiento de Retina/cirugía , Cirugía Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos , Femenino , Humanos , Enfermedades del Nervio Óptico/congénito , Enfermedades del Nervio Óptico/diagnóstico , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/etiología , Síndrome , Agudeza Visual , Adulto Joven
11.
J Cataract Refract Surg ; 42(5): 694-702, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27255245

RESUMEN

PURPOSE: To assess the position of intraocular lenses (IOLs) at the end of standard phacoemulsification with intraoperative spectral-domain optical coherence tomography (SD-OCT). SETTINGS: Department of Ophthalmology, Rudolf Foundation Hospital, Vienna, Austria. DESIGN: Prospective case series. METHODS: Standard phacoemulsification with IOL implantation was performed. The Rescan 700 SD-OCT system was used for intraoperative imaging. The anterior segment of the eye was scanned using SD-OCT at the end of the surgery. The distance from the IOL optic center and the IOL optic edge to the posterior capsule was measured postoperatively using graphic software. RESULTS: The study comprised 74 patients (101 eyes). The mean axial length was 23.97 mm (range 21.43 to 28.61 mm). The mean IOL power was 20.39 diopters (D) (range 6.5 to 27.5 D). Contact between the IOL and posterior capsule was absent in 88 cases (87.13%), and partial or full contact was present in 13 cases (12.87%). The mean distance between the IOL central optic and posterior capsule was 0.71 pixel (range 0.06 to 1.38 pixels) in 99 cases (98.02%). In 42 cases (57.53%), partial contact between the IOL edges and the posterior capsule was noticed. The mean distance between the IOL edge and posterior capsule was 0.21 pixel (range 0.04 to 0.92 pixel). CONCLUSIONS: Intraoperative SD-OCT facilitated the imaging of IOL position during standard phacoemulsification. Contact between the IOL central optic and posterior capsule at the end of the surgery occurred rarely. Improved IOL design should be considered. FINANCIAL DISCLOSURE: Drs. Binder and Glittenberg are consultants to Carl Zeiss Meditech AG. None of the other authors has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Implantación de Lentes Intraoculares , Facoemulsificación , Tomografía de Coherencia Óptica , Humanos , Lentes Intraoculares , Complicaciones Posoperatorias , Estudios Prospectivos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA