Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 20(20): 22034-41, 2012 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-23037353

RESUMEN

Optical frequency comparison of the (40)Ca(+) clock transition ν(Ca)((2)S(1/2-)(2D(5/2), 729 nm) against the (87)Sr optical lattice clock transition ν(Sr) ((1)S(0)-(3)P(0), 698 nm) has resulted in a frequency ratio ν(Ca) / ν(Sr) = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν(Ca) / ν(Sr) to reach 1 × 10(-15) in 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν(Ca) using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We note that the absolute frequency of (40)Ca(+) we measure deviates from other published values by more than three times our measurement uncertainty.


Asunto(s)
Calcio/química , Dispositivos Ópticos , Oscilometría/instrumentación , Oscilometría/métodos , Estroncio/química , Factores de Tiempo , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
2.
Artículo en Inglés | MEDLINE | ID: mdl-17186921

RESUMEN

Cryogenic sapphire oscillators (CSO) developed at the University of Western Australia (UWA) have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10(14) per day to a few parts in 10(13) per day.


Asunto(s)
Óxido de Aluminio , Frío , Electroquímica/instrumentación , Electrónica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
3.
Phys Rev Lett ; 95(4): 040404, 2005 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-16090785

RESUMEN

We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz invariance in the framework of the photon sector of the standard model extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured kappa(ZZ)(e-) component of 2.1(5.7) x 10(-14), and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of -0.9(2.0) x 10(-10) on the isotropy parameter, P(MM) = delta-beta + 1 / 2 is set, which is more than a factor of 7 improvement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA